Behavior of headed stud shear connectors in composite beam

被引:315
作者
Lam, D [1 ]
El-Lobody, E [1 ]
机构
[1] Univ Leeds, Sch Civil Engn, Leeds LS2 9JT, W Yorkshire, England
关键词
Composite beams; Connectors; mechanical; Finite element method; Pull-out resistance; Shear deformation; Steel structures;
D O I
10.1061/(ASCE)0733-9445(2005)131:1(96)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In composite beam design, headed stud shear connectors are commonly used to transfer longitudinal shear forces across the steel-concrete interface. Present knowledge of the load-slip behavior and the shear capacity of the shear stud in composite beam are limited to data obtained from the experimental push-off tests. For this purpose, an effective numerical model using the finite element method to simulate the push-off test was proposed. The model has been validated against test results and compared with data given in the current Code of Practices, i.e., BS5950, EC4, and AISC. Parametric studies using this model were preformed to investigate variations in concrete strength and shear stud diameter. The finite element model provided a better understanding to the different modes of failure observed during experimental testing and hence shear capacity of headed shear studs in solid concrete slabs.
引用
收藏
页码:96 / 107
页数:12
相关论文
共 10 条
[1]   Push-out tests on studs in high strength and normal strength concrete [J].
An, L ;
Cederwall, K .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1996, 36 (01) :15-29
[2]  
*BRIT STAND I, 1994, 199411 DD ENV
[3]  
*BRIT STAND I, 1965, COMP CONSTR STRUCT S
[4]  
British Standards Institution, 1997, 8110 BS
[5]   BEHAVIOR OF HEADED STUDS IN COMPOSITE BEAMS - PUSH-OUT TESTS [J].
JAYAS, BS ;
HOSAIN, MU .
CANADIAN JOURNAL OF CIVIL ENGINEERING, 1988, 15 (02) :240-253
[6]  
Lam D, 1998, STRUCTURAL ENG, V76, P167
[7]  
MacMackin P.J., 1973, ENG J, V2Q, P43
[8]  
Menzies JB, 1971, The Structural Engineer, V49, P137
[9]  
Rose JN., 1903, B NEW YORK BOT GARD, V3, P1, DOI DOI 10.2307/2475877
[10]  
2001, USERS MANUAL VER 6 2