A two-channel microfluidic sensor that uses anodic electrogenerated chemiluminescence as a photonic reporter of cathodic redox reactions

被引:47
作者
Zhan, W [1 ]
Alvarez, J [1 ]
Crooks, RM [1 ]
机构
[1] Texas A&M Univ, Dept Chem, College Stn, TX 77842 USA
关键词
D O I
10.1021/ac020488h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes a new approach for sensing electrochemically active substrates in microfluidic systems. This two-electrode sensor relies on electrochemical detection at one electrode and electrogenerated chemiluminescent (ECL) reporting at the other. Each microfabricated indium tin oxide electrode is located in a separate microfluidic channel, but the channels are connected downstream of the electrodes to maintain a complete electrical circuit. Because of laminar flow, there is no bulk mixing of the fluids in the detecting and reporting channels. This approach allows the ECL reaction to be physically and chemically decoupled from the sensing channel of the device, which greatly expands the number of analytes that can be detected. However, because the cathode and anode are connected, electron-transfer processes occurring at the sensing electrode are electrically coupled to the ECL reaction. Charge balance permits the ECL light output to be quantitatively correlated to electrochemical reductions at the cathode. The system is used to detect Fe(CN)(6)(3-), Ru(NH3)(6)(3+), and benzyl viologen and report their presence via Ru(bpy)(3)(2+) (bpy = bipyridine) luminescence. Each different redox target initiates ECL at a unique potential bias related to its standard redox potential. The influence of the concentrations of Ru(bpy)(3)(2-) and the target analytes is discussed.
引用
收藏
页码:313 / 318
页数:6
相关论文
共 25 条
[1]   Sub-microliter electrochemiluminescence detector - A model for small volume analysis systems [J].
Arora, A ;
de Mello, AJ ;
Manz, A .
ANALYTICAL COMMUNICATIONS, 1997, 34 (12) :393-395
[2]   A wireless electrochemiluminescence detector applied to direct and indirect detection for electrophoresis on a microfabricated glass device [J].
Arora, A ;
Eijkel, JCT ;
Morf, WE ;
Manz, A .
ANALYTICAL CHEMISTRY, 2001, 73 (14) :3282-3288
[3]   Plastic advances microfluidic devices. [J].
Boone, T ;
Fan, ZH ;
Hooper, H ;
Ricco, A ;
Tan, HD ;
Williams, S .
ANALYTICAL CHEMISTRY, 2002, 74 (03) :78A-86A
[4]   Chemiluminescence detection for hybridization assays on the flow-thru chip, a three-dimensional microchannel biochip [J].
Cheek, BJ ;
Steel, AB ;
Torres, MP ;
Yu, YY ;
Yang, HJ .
ANALYTICAL CHEMISTRY, 2001, 73 (24) :5777-5783
[5]   Microchip-based capillary electrophoresis for immunoassays: Analysis of monoclonal antibodies and theophylline [J].
Chiem, N ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 1997, 69 (03) :373-378
[6]   Recent applications of electrogenerated chemiluminescence in chemical analysis [J].
Fähnrich, KA ;
Pravda, M ;
Guilbault, GG .
TALANTA, 2001, 54 (04) :531-559
[7]   Lab-on-a-chip: A revolution in biological and medical sciences. [J].
Figeys, D ;
Pinto, D .
ANALYTICAL CHEMISTRY, 2000, 72 (09) :330A-335A
[8]   Voltammetric and reference microelectrodes with integrated microchannels for flow through microvoltammetry. 2. Coupling the microcell to a supported liquid membrane preconcentration technique [J].
Keller, OC ;
Buffle, J .
ANALYTICAL CHEMISTRY, 2000, 72 (05) :943-948
[9]   Voltammetric and reference microelectrodes with integrated microchannels for flow through microvoltammetry. 1. The microcell [J].
Keller, OC ;
Buffle, J .
ANALYTICAL CHEMISTRY, 2000, 72 (05) :936-942
[10]   A review of recent trends in analytical applications of electrogenerated chemiluminescence [J].
Knight, AW .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1999, 18 (01) :47-62