Design study of a raster scanning system for moving target irradiation in heavy-ion radiotherapy

被引:115
作者
Furukawa, Takuji [1 ]
Inaniwa, Taku [1 ]
Sato, Shinji [1 ]
Tomitani, Takehiro [1 ]
Minohara, Shinichi [1 ]
Noda, Koji [1 ]
Kanai, Tatsuaki [1 ]
机构
[1] Natl Inst Radiol Sci, Res Ctr Charged Particle Therapy, Med Phys Res Grp, Inage Ku, Chiba 2638555, Japan
关键词
particle therapy; pencil beam scanning; moving target;
D O I
10.1118/1.2558213
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
A project to construct a new treatment facility as an extension of the existing heavy-ion medical accelerator in chiba (HIMAC) facility has been initiated for further development of carbon-ion therapy. The greatest challenge of this project is to realize treatment of a moving target by scanning irradiation. For this purpose, we decided to combine the rescanning technique and the gated irradiation method. To determine how to avoid hot and/or cold spots by the relatively large number of rescannings within an acceptable irradiation time, we have studied the scanning strategy, scanning magnets and their control, and beam intensity dynamic control. We have designed a raster scanning system and carried out a simulation of irradiating moving targets. The result shows the possibility of practical realization of moving target irradiation with pencil beam scanning. We describe the present status of our design study of the raster scanning system for the HIMAC new treatment facility. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:1085 / 1097
页数:13
相关论文
共 28 条
[1]
[Anonymous], 1999, 62 ICRU
[2]
Residual motion of lung tumours in gated radiotherapy with external respiratory surrogates [J].
Berbeco, RI ;
Nishioka, S ;
Shirato, H ;
Chen, GTY ;
Jiang, SB .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (16) :3655-3667
[3]
INSTRUMENTATION FOR TREATMENT OF CANCER USING PROTON AND LIGHT-ION BEAMS [J].
CHU, WT ;
LUDEWIGT, BA ;
RENNER, TR .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (08) :2055-2122
[4]
Intensity control in RF-knockout extraction for scanning irradiation [J].
Furukawa, T ;
Noda, K ;
Uesugi, TH ;
Naruse, T ;
Shibuya, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2005, 240 (1-2) :32-35
[5]
Characteristics of fast beam switching for spot scanning [J].
Furukawa, T ;
Noda, K ;
Urakabe, E ;
Muramatsu, M ;
Kanazawa, M ;
Maeda, K .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 503 (03) :485-495
[6]
Global spill control in RF-knockout slow-extraction [J].
Furukawaa, T ;
Noda, K ;
Muramatsu, M ;
Uesugi, T ;
Shibuya, S ;
Kawal, H ;
Takada, E ;
Yamada, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 522 (03) :196-204
[7]
Simulations to design an online motion compensation system for scanned particle beams [J].
Groezinger, Sven Oliver ;
Rietzel, Eike ;
Li, Qiang ;
Bert, Christoph ;
Haberer, Thomas ;
Kraft, Gerhard .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (14) :3517-3531
[8]
MAGNETIC SCANNING SYSTEM FOR HEAVY-ION THERAPY [J].
HABERER, T ;
BECHER, W ;
SCHARDT, D ;
KRAFT, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 330 (1-2) :296-305
[9]
HABERER T, 2004, 2003 GSI, P171
[10]
HIRAO Y, 1992, NUCL PHYS A, V538, pC541, DOI 10.1016/0375-9474(92)90803-R