Autologous conjunctival resurfacing of leaking filtering blebs

被引:27
作者
Harris, LD
Yang, G
Feldman, RM
Fellman, RL
Starita, RJ
Lynn, J
Chuang, AZ
机构
[1] Univ Texas, Hlth Sci Ctr, Hermann Eye Ctr, Houston, TX 77030 USA
[2] Mem Hermann Hosp Syst, Ctr Hlth Care, Houston, TX USA
[3] Glaucoma Associates Texas, Dallas, TX USA
关键词
D O I
10.1016/S0161-6420(00)00280-3
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purposes To present a case series of a new technique to repair late bleb leaks. Designs:Retrospective, noncomparative, consecutive case series. Participants: Forty-seven autologous conjunctival resurfacings of late bleb leaks were performed by four surgeons at two institutions. Methods: Autologous conjunctival grafts were placed over existing de-epithelialized leaking blebs. Main Outcome Measures: Leak-free, Seidel-negative blebs and controlled glaucoma. Results: After a mean follow-up of 14 +/- 12 months, one patient continued to have bleb leak at the last follow-up, and one frank leak resolved with aqueous suppression. Intraocular pressure increased from 6.6 +/- 4.4 mmHg (0.13 glaucoma medications) to 11.9 +/- 4.1 mmHg (0.41 glaucoma medications). Conclusions: Conjunctival resurfacing with autologous tissue is an effective technique to repair late bleb leaks. Ophthalmology 2000;107:1675-1680 (C) 2000 by the American Academy of Ophthalmology.
引用
收藏
页码:1675 / 1680
页数:6
相关论文
共 25 条
[1]  
ALWARD WLM, 1993, AM J OPHTHALMOL, V115, P82
[2]  
Alward WLM, 1996, AM J OPHTHALMOL, V121, P349
[3]   ARGON-LASER CLOSURE OF CONJUNCTIVAL BLEB LEAK [J].
BAUM, M ;
WEISS, HS .
ARCHIVES OF OPHTHALMOLOGY, 1993, 111 (04) :438-438
[4]   Late onset of sequential multifocal bleb leaks after glaucoma filtration surgery with 5-fluorouracil and mitomycin C [J].
Belyea, DA ;
Dan, JA ;
Stamper, RL ;
Lieberman, MF ;
Spencer, WH .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1997, 124 (01) :40-45
[5]  
DIETZE PJ, 1992, OPHTHALMIC SURG LAS, V23, P662
[6]   USE OF A COLLAGEN SHIELD TO TREAT A GLAUCOMA FILTER BLEB LEAK [J].
FOURMAN, S ;
WILEY, L .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1989, 107 (06) :673-674
[7]  
Gammon RR, 1998, OPHTHALMIC SURG LAS, V29, P1010
[8]   Management of large, leaking, and inadvertent filtering blebs with the neodymium:YAG laser [J].
Geyer, O .
OPHTHALMOLOGY, 1998, 105 (06) :983-987
[9]   Late-onset bleb leaks after glaucoma filtering surgery [J].
Greenfield, DS ;
Liebmann, JM ;
Jee, J ;
Ritch, R .
ARCHIVES OF OPHTHALMOLOGY, 1998, 116 (04) :443-447
[10]   USE OF THE ARGON-LASER TO CLOSE FILTERING BLEB LEAKS [J].
HENNIS, HL ;
STEWART, WC .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1992, 230 (06) :537-541