Is fasting blood glucose a reliable parameter for screening for diabetes in hypertension?

被引:11
作者
Bur, A [1 ]
Herkner, H [1 ]
Woisetschläger, C [1 ]
Vlcek, M [1 ]
Derhaschnig, U [1 ]
Hirschl, MM [1 ]
机构
[1] Univ Vienna, Gen Hosp, Dept Emergency Med, Vienna, Austria
关键词
hypertension; diabetes; screening; fasting plasma glucose; glycosylated hemoglobin; oral glucose tolerance test; WORLD-HEALTH-ORGANIZATION; ASSOCIATION DIAGNOSTIC-CRITERIA; CARDIOVASCULAR-DISEASE; TOLERANCE TEST; RISK; MELLITUS; REPRODUCIBILITY; POPULATION; PREVALENCE; CATEGORIES;
D O I
10.1016/S0895-7061(02)03273-9
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background: The aim of this study was to evaluate the sensitivity and specificity of a combination of fasting plasma glucose (FPG) and glycosylated hemoglobin (HbA(1c)) for screening for diabetes in hypertensive patients. The oral glucose tolerance test (OGTT) served as a gold standard for the detection of diabetes. Methods: The cross-sectional study was performed in the Hypertension Unit of the Department of Emergency Medicine in the General Hospital of Vienna between January 1999 and July 2001. The FPG, HbA(1c), and OGTT were performed in 152 hypertensive patients (77 male and 75 female) to identify those individuals with diabetes. Results: A total of 33 patients were identified as diabetic based on the results of the OGTT. Diabetes was detected in 25 (16%) of 152 patients using an FPG greater than or equal to7.0 mmol/L. In addition, HbA(1c) was measured in the remaining 127 (84%) patients with an FPG <7.0 mmol/L. In these patients HbA(1c) greater than or equal to6.1% showed a sensitivity of 100% and a specificity of 75%. Cost analysis of both approaches (FPG + HbA(1c) versus OGTT in all patients) demonstrated a cost sparing effect of 31.03 $/patient (31.66$/patient) in favor of the combined use of FPG and HbA(1c). Conclusion: The combination of FPG and HbA(1c) is a reasonable alternative to the generally recommended OGTT for the screening of diabetes, as diabetes was correctly diagnosed in all patients by this stepwise procedure. Am J Hypertens 2003;16:297-301 (C) 2003 American Journal of Hypertension, Ltd.
引用
收藏
页码:297 / 301
页数:5
相关论文
共 30 条
[1]   Should we do an oral glucose tolerance test in hypertensive men with normal tasting blood-glucose? [J].
Agewall, S .
JOURNAL OF HUMAN HYPERTENSION, 2001, 15 (01) :71-74
[2]  
Alberti KGMM, 1998, DIABETIC MED, V15, P539, DOI 10.1002/(SICI)1096-9136(199807)15:7<539::AID-DIA668>3.0.CO
[3]  
2-S
[4]  
[Anonymous], 1999, Diabetologia, V42, P647
[5]  
[Anonymous], 1997, ARCH INTERN MED, V157, P2413, DOI DOI 10.1001/ARCHINTE.157.21.2413
[6]  
Chalmers J, 1999, J HYPERTENS, V17, P151
[7]   HIGH SYSTOLIC BLOOD-PRESSURE INCREASES PREVALENCE AND SEVERITY OF RETINOPATHY IN NIDDM PATIENTS [J].
CIGNARELLI, M ;
DECICCO, ML ;
DAMATO, A ;
PATERNOSTRO, A ;
PAGLIARINI, S ;
SANTORO, S ;
CARDIA, L ;
DEPERGOLA, G ;
GIORGINO, R .
DIABETES CARE, 1992, 15 (08) :1002-1008
[8]   Effect of diuretic-based antihypertensive treatment on cardiovascular disease risk in older diabetic patients with isolated systolic hypertension [J].
Curb, JD ;
Pressel, SL ;
Cutler, JA ;
Savage, PJ ;
Applegate, WB ;
Black, H ;
Camel, G ;
Davis, BR ;
Frost, PH ;
Gonzalez, N ;
Guthrie, G ;
Oberman, A ;
Rutan, GH ;
Stamler, J .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (23) :1886-1892
[9]   Cardiovascular morbidity and mortality in the Losartan Intervention For Endpoint reduction in hypertension study (LIFE):: a randomised trial against atenolol [J].
Dahlöf, B ;
Devereux, RB ;
Kjeldsen, SE ;
Julius, S ;
Beevers, G ;
de Faire, U ;
Fyhrquist, F ;
Ibsen, H ;
Kristiansson, K ;
Lederballe-Pedersen, O ;
Lindholm, LH ;
Nieminen, MS ;
Omvik, P ;
Oparil, S ;
Wedel, H .
LANCET, 2002, 359 (9311) :995-1003
[10]   The 1997 American Diabetes Association criteria versus the 1985 World Health Organization criteria for the diagnosis of abnormal glucose tolerance - Poor agreement in the Hoorn study [J].
De Vegt, F ;
Dekker, JM ;
Stehouwer, CDA ;
Nijpels, G ;
Bouter, LM ;
Heine, R .
DIABETES CARE, 1998, 21 (10) :1686-1690