Design of an MR-Compatible piezoelectric actuator for MR elastography

被引:31
作者
Uffmann, K
Abicht, C
Grote, W
Quick, HH
Ladd, ME
机构
[1] Univ Hosp Essen, Dept Diagnost & Intervent Radiol, D-45122 Essen, Germany
[2] Tech Univ Munich, Inst Mechatron, D-8000 Munich, Germany
来源
CONCEPTS IN MAGNETIC RESONANCE | 2002年 / 15卷 / 04期
关键词
elasticity; elastography; actuator; MRI; acceleration sensor; piezoelectric;
D O I
10.1002/cmr.10045
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Magnetic Resonance (MR) elastography is a method for measuring tissue elasticity via phase images acquired with an MR scanner. The propagation of periodic mechanical waves through the tissue can be captured by means of a modified phase contrast sequence. These waves are generated with a mechanical oscillator (actuator) and coupled into the tissue through the skin. The actuator must be capable of generating a sinusoidal excitation with excellent phase and amplitude stability, while not disturbing the MR imaging process. In this work, an actuator based on a piezoelectric principle was developed. Based on the imaging evaluation of several material samples, the housing for the piezoelectric ceramic was constructed of aluminum. Smaller parts of the housing were manufactured from brass and titanium to fulfill the mechanical constraints. A lever was used to transfer the oscillation generated by the piezoelectric ceramic to the point of excitation. The lever amplifies the piezoelectric motion, allowing for a more compact design. Three different lever designs were characterized by an acceleration sensor both outside and inside the magnet. It was shown that the rigidity of the lever, as determined by its material and form, was decisive in determining the resonant frequency of the system and therefore the maximum practical frequency of operation. It was also shown that the motion of the oscillator is unaffected by the electromagnetic fields of the MR imager. The final design can be placed directly in the magnet bore within a few centimeters of the tissue volume to be imaged without generating significant artifacts. An amplitude range of 0-1 mm in the frequency range from 0 to over 300 Hz was achieved, sufficient for performing most MR elastography applications. (C) 2002 Wiley Periodicals, Inc.
引用
收藏
页码:239 / 254
页数:16
相关论文
共 24 条
[1]   Two-dimensional MR elastrography with linear inversion reconstruction: methodology and noise analysis [J].
Bishop, J ;
Samani, A ;
Sciarretta, J ;
Plewes, DB .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (08) :2081-2091
[2]   Magnetic resonance imaging of shear wave propagation in excised tissue [J].
Bishop, J ;
Poole, G ;
Leitch, M ;
Plewes, DB .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (06) :1257-1265
[3]   NONSUSCEPTIBILITY ARTIFACTS DUE TO METALLIC OBJECTS IN MR-IMAGING [J].
CAMACHO, CR ;
PLEWES, DB ;
HENKELMAN, RM .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (01) :75-88
[4]  
Dresner MA, 2001, J MAGN RESON IMAGING, V13, P269, DOI 10.1002/1522-2586(200102)13:2<269::AID-JMRI1039>3.3.CO
[5]  
2-T
[6]  
DUBBEL H, 1987, TASCHENBUCH MASCHINE, pE65
[7]   Acoustic shear-wave imaging using echo ultrasound compared to magnetic resonance elastography [J].
Dutt, V ;
Kinnick, RR ;
Muthupillai, R ;
Oliphant, TE ;
Ehman, RL ;
Greenleaf, JF .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (03) :397-403
[8]   SONOELASTICITY IMAGES DERIVED FROM ULTRASOUND SIGNALS IN MECHANICALLY VIBRATED TISSUES [J].
LERNER, RM ;
HUANG, SR ;
PARKER, KJ .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (03) :231-239
[9]   Imaging of breast tumors using MR-Elastography. [J].
Lorenzen, J ;
Sinkus, R ;
Schrader, D ;
Lorenzen, M ;
Leussler, C ;
Dargatz, M ;
Röschmann, P .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (01) :12-17
[10]   MAGNETIC-RESONANCE ELASTOGRAPHY BY DIRECT VISUALIZATION OF PROPAGATING ACOUSTIC STRAIN WAVES [J].
MUTHUPILLAI, R ;
LOMAS, DJ ;
ROSSMAN, PJ ;
GREENLEAF, JF ;
MANDUCA, A ;
EHMAN, RL .
SCIENCE, 1995, 269 (5232) :1854-1857