Small-volume on-line sensor for continuous measurement of γ-aminobutyric acid

被引:65
作者
Niwa, O
Kurita, R
Horiuchi, T
Torimitsu, K
机构
[1] NTT Basic Res Labs, Kanagawa 24301, Japan
[2] NTT Adv Technol, Kanagawa 24301, Japan
关键词
D O I
10.1021/ac970740z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report the first on-line electrochemical sensor for the continuous measurement of gamma-aminobutyric acid (GABA), which is a well-known inhibitory neurotransmitter in the nervous system. The sensor is composed of a glutamate oxidase (GluOx) and catalase immobilized small-volume enzymatic reactor and a glassy carbon (GC) electrode modified with a top layer film consisting of gabase and GluOx coimmobilized bovine serum albumin and an Os-poly(vinylpyrridine) bottom layer film containing horseradish peroxidase. The response of the sensor depends on the a-ketoglutarate concentration and is almost saturated when its concentration is 100 times higher than GABA, The sensor exhibits a sensitivity of 1.56 nA/mu M for GABA under optimized conditions and shows almost no response when 10 mu M glutamate is continuously injected. A detection limit of 0.1 mu M is obtained with a linear range of 0.1-10 mu M. GABA can be measured in the absence of alpha-ketoglutarate when there is L-glutamate in the sample solution, which is a typical condition for the extracellular measurement of cultured nerve cells.
引用
收藏
页码:89 / 93
页数:5
相关论文
共 14 条
[1]   THE DIALYSIS ELECTRODE - A NEW METHOD FOR INVIVO MONITORING [J].
ALBERY, WJ ;
BOUTELLE, MG ;
GALLEY, PT .
JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1992, (12) :900-901
[2]   REAL-TIME MEASUREMENT OF TRANSMITTER RELEASE FROM SINGLE SYNAPTIC VESICLES [J].
BRUNS, D ;
JAHN, R .
NATURE, 1995, 377 (6544) :62-65
[3]   DETERMINATION OF GAMMA-AMINOBUTYRIC ACID BY LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION [J].
CAUDILL, WL ;
HOUCK, GP ;
WIGHTMAN, RM .
JOURNAL OF CHROMATOGRAPHY, 1982, 227 (02) :331-339
[4]   REAL-TIME MONITORING OF ELECTRICALLY STIMULATED NOREPINEPHRINE RELEASE IN RAT THALAMUS .1. RESOLUTION OF TRANSMITTER AND METABOLITE SIGNAL COMPONENTS [J].
GHASEMZADEH, MB ;
CAPELLA, P ;
MITCHELL, K ;
ADAMS, RN .
JOURNAL OF NEUROCHEMISTRY, 1993, 60 (02) :442-448
[5]   DIRECT MEASUREMENT OF GLUTAMATE RELEASE IN THE BRAIN USING A DUAL ENZYME-BASED ELECTROCHEMICAL SENSOR [J].
HU, YB ;
MITCHELL, KM ;
ALBAHADILY, FN ;
MICHAELIS, EK ;
WILSON, GS .
BRAIN RESEARCH, 1994, 659 (1-2) :117-125
[6]   REGULATION OF TRANSIENT DOPAMINE CONCENTRATION GRADIENTS IN THE MICROENVIRONMENT SURROUNDING NERVE-TERMINALS IN THE RAT STRIATUM [J].
KAWAGOE, KT ;
GARRIS, PA ;
WIEDEMANN, DJ ;
WIGHTMAN, RM .
NEUROSCIENCE, 1992, 51 (01) :55-64
[7]   PURIFICATION AND PROPERTIES OF A NEW ENZYME, L-GLUTAMATE OXIDASE, FROM STREPTOMYCES SP X-119-6 GROWN ON WHEAT BRAN [J].
KUSAKABE, H ;
MIDORIKAWA, Y ;
FUJISHIMA, T ;
KUNINAKA, A ;
YOSHINO, H .
AGRICULTURAL AND BIOLOGICAL CHEMISTRY, 1983, 47 (06) :1323-1328
[8]   Concentration of extracellular L-glutamate released from cultured nerve cells measured with a small volume online sensor [J].
Niwa, O ;
Torimitsu, K ;
Morita, M ;
Osborne, P ;
Yamamoto, K .
ANALYTICAL CHEMISTRY, 1996, 68 (11) :1865-1870
[9]   Continuous monitoring of L-glutamate released from cultured nerve cells by an online sensor coupled with micro-capillary sampling [J].
Niwa, O ;
Horiuchi, T ;
Torimitsu, K .
BIOSENSORS & BIOELECTRONICS, 1997, 12 (04) :311-319
[10]   ENZYME-INHIBITION .10. COLORIMETRIC METHOD FOR DETERMINING GABASE ACTIVITY AND ITS COMPARISON WITH A SPECTROPHOTOMETRIC METHOD [J].
SETHI, ML .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (07) :613-617