The effect of window width on radiation dose in CT-examinations of high-contrast structures

被引:18
作者
Husstedt, H
Prokop, M
Becker, H
机构
[1] Med Hsch Hannover, Abt Neuroradiol, Hannover, Germany
[2] Med Hsch Hannover, Abt Diagnost Radiol 1, Hannover, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 1998年 / 168卷 / 02期
关键词
computed tomography; dose reduction; window width; documentation parameters;
D O I
10.1055/s-2007-1015198
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Purpose: To establish the relationship between window width and dose to be applied in low-dose high-resolution (HR) computed tomography (CT). Material and methods: Low-dose HR CT-scans of the petrous bone displayed with different window values were analyzed for identification of osseous details. For two homogenous phantoms, standard deviation of CT-numbers were measured in order to calculate the fraction of pixels not displayed within the correct grey level. Results: The broadest window used (4000 HU) allowed the best distinction of osseous structures. Standard deviation of CT-numbers in the phantoms varied between 28.5 and 43.2 (mean = 33.6) HU. Thus, only 26.6% of all pixels are displayed in the correct grey level for a 1000 HU-window, but 82.3% for a 4000 HU-window. Conclusion: When using low doses and HR-reconstruction algorithms, large window widths allow for an optimal assessment of high-contrast structures. Under these conditions, even high standard deviations of the CT-numbers will not compromise image evaluation. Due to the restricted number of grey-levels that can be distinguished by the human eye, image noise is compressed into a smaller number of discernable grey-levels. Because of the inverse square root function between dose to be applied and window width used (derived in the article), an even minor enlargement of window permits considerable reductions of patient exposure while the discernable image noise remains constant.
引用
收藏
页码:139 / 143
页数:5
相关论文
共 16 条
[1]
CHARACTERISTICS AND CONTROL OF CONTRAST IN CT [J].
BARNES, JE .
RADIOGRAPHICS, 1992, 12 (04) :825-837
[2]
BECKER H, 1995, NEURORADIOLOGY, V37, P390
[3]
*DEETJ SPECKM, 1994, PHYSIOLOGIE
[4]
DIETRICH B, 1993, KLIN NEURORADIOL, V3, P29
[5]
GUDDEN F, 1992, BIOMEDIZINISCHE TECH, V1
[6]
HENSCHEL GM, 1995, ROFO FORTSCHR RONTG, V162, P269
[7]
DISPLAY THRESHOLDING OF IMAGES AND OBSERVER DETECTION PERFORMANCE [J].
JUDY, PF ;
SWENSSON, RG .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1987, 4 (05) :954-965
[8]
DETECTION OF SMALL FOCAL LESIONS IN CT IMAGES - EFFECTS OF RECONSTRUCTION FILTERS AND VISUAL-DISPLAY WINDOWS [J].
JUDY, PF ;
SWENSSON, RG .
BRITISH JOURNAL OF RADIOLOGY, 1985, 58 (686) :137-145
[9]
PATIENT DOSE-RATE - ULTIMATE LIMIT FOR SPATIAL AND DENSITY RESOLUTION OF SCANNING SYSTEMS [J].
KOWALSKI, G ;
WAGNER, W .
BIOMEDIZINISCHE TECHNIK, 1979, 24 (03) :38-42
[10]
HISTOGRAM EQUALIZATION OF CT IMAGES [J].
LEHR, JL ;
CAPEK, P .
RADIOLOGY, 1985, 154 (01) :163-169