Whole blood and red blood cell manganese reflected signal intensities of T1-weighted magnetic resonance images better than plasma manganese in liver cirrhotics

被引:24
作者
Choi, Y
Park, JK
Park, NH
Shin, JW
Yoo, CI
Lee, CR
Lee, H
Kim, HK
Kim, SR
Jung, TH
Park, J
Yoon, CS
Kim, Y
机构
[1] Ulsan Univ Hosp, Dept Occupat & Environm Med, Ulsan 682060, South Korea
[2] Ulsan Univ Hosp, Dept Radiol, Ulsan 682060, South Korea
[3] Ulsan Univ Hosp, Dept Internal Med, Ulsan 682060, South Korea
[4] Ulsan Univ Hosp, Dept Neurol, Ulsan 682060, South Korea
[5] Ulsan Univ Hosp, Dept Clin Pathol, Ulsan 682060, South Korea
[6] Ulsan Univ Hosp, Dept Family Med, Ulsan 682060, South Korea
[7] Catholic Univ, Korea Occupat Safety & Hlth Agcy, Taegu, South Korea
[8] Catholic Univ, Dept Occupat Hlth, Taegu, South Korea
关键词
manganese; signal intensity; magnetic resonance; liver cirrhosis; pallidal index;
D O I
10.1539/joh.47.68
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
We examined whole blood (MnB), red blood cell (MnRBC), plasma (MnP) and urinary Mn (MnU) concentrations in 22 liver cirrhotics and 10 healthy controls to evaluate Mn concentration in which a fraction of biological samples best reflects pallidal signal intensities (pallidal index; PI) on T1-weighted magnetic resonance images (MRI) in liver cirrhotics. Increased signal intensity in the globus pallidus was observed in 18 (81.8%) of the 22 patients with liver cirrhosis. In a transplanted patient, increased pallidal signals also resolved as his liver function tests normalized after liver transplantation. There were significant correlations between MnB/MnRBC and PI (rho=0.529, rho=0.573, respectively) in liver cirrhotics although no significant correlation was observed between MnP/MnU and PI. According to a multiple linear regression, MnB and MnRBC reflected the signal intensities of T1-weighted MRI better than MnP or MnU.
引用
收藏
页码:68 / 73
页数:6
相关论文
共 28 条
[1]   Calcification mimicking manganese-induced increased signal intensities in T1-weighted MR images in a patient taking herbal medicine: Case report [J].
Ahn, JH ;
Yoo, CI ;
Lee, CR ;
Lee, JH ;
Lee, H ;
Kim, CY ;
Park, JK ;
Sakai, T ;
Yoon, CS ;
Kim, Y .
NEUROTOXICOLOGY, 2003, 24 (06) :835-838
[2]   LOW-VOLUME MICROWAVE DIGESTION OF MARINE BIOLOGICAL TISSUES FOR THE MEASUREMENT OF TRACE-ELEMENTS [J].
BALDWIN, S ;
DEAKER, M ;
MAHER, W .
ANALYST, 1994, 119 (08) :1701-1704
[3]   Manganese toxicity, dopaminergic dysfunction and hepatic encephalopathy [J].
Butterworth, RF ;
Spahr, L ;
Fontaine, S ;
Layrargues, GP .
METABOLIC BRAIN DISEASE, 1995, 10 (04) :259-267
[4]   ANALYSIS OF WHOLE-BLOOD MANGANESE BY FLAMELESS ATOMIC-ABSORPTION SPECTROPHOTOMETRY AND ITS USE AS AN INDICATOR OF MANGANESE STATUS IN ANIMALS [J].
CLEGG, MS ;
LONNERDAL, B ;
HURLEY, LS ;
KEEN, CL .
ANALYTICAL BIOCHEMISTRY, 1986, 157 (01) :12-18
[5]  
DELL LA, 1988, AM J NEURORADIOL, V9, P1145
[6]   MANGANESE INTOXICATION DURING TOTAL PARENTERAL-NUTRITION [J].
EJIMA, A ;
IMAMURA, T ;
NAKAMURA, S ;
SAITO, H ;
MATSUMOTO, K ;
MOMONO, S .
LANCET, 1992, 339 (8790) :426-426
[7]  
Francois B, 1988, CLIN CHEM, V34, P227
[8]   CHOROIDAL MELANOMAS - CORRELATION OF NMR-SPECTROSCOPY AND MR IMAGING [J].
GOMORI, JM ;
GROSSMAN, RI ;
SHIELDS, JA ;
AUGSBURGER, JJ ;
JOSEPH, PM ;
DESIMEONE, D .
RADIOLOGY, 1986, 158 (02) :443-445
[9]   INTRACRANIAL HEMATOMAS - IMAGING BY HIGH-FIELD MR [J].
GOMORI, JM ;
GROSSMAN, RI ;
GOLDBERG, HI ;
ZIMMERMAN, RA ;
BILANIUK, LT .
RADIOLOGY, 1985, 157 (01) :87-93
[10]   MANGANESE INTOXICATION AND CHRONIC LIVER-FAILURE [J].
HAUSER, RA ;
ZESIEWICZ, TA ;
ROSEMURGY, AS ;
MARTINEZ, C ;
OLANOW, CW .
ANNALS OF NEUROLOGY, 1994, 36 (06) :871-875