Comparison of conventional and gaze-down imaging in laparoscopic task performance

被引:13
作者
Brown, SI [1 ]
Frank, TG [1 ]
El Shallaly, G [1 ]
Cuschieri, A [1 ]
机构
[1] Univ Dundee, Ninewells Hosp & Med Sch, Dept Surg & Mol Oncol, Dundee DD1 9SY, Scotland
来源
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES | 2003年 / 17卷 / 04期
关键词
projection; image quality; task performance;
D O I
10.1007/s00464-002-8525-3
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: In video-assisted laparoscopy, the image is usually displayed on a monitor placed at approximately eye level. Video projection systems project the image onto a screen placed close to the hands. This is said to be ergonomically superior. To evaluate this approach, a proprietary projection system (PS) was compared to a monitor display (MD). Method: The resolution, ghosting, flickering, glare, contrast, color smear, and color matching of the two modalities were compared. A bowel-suturing task was employed to evaluate performance differences. Results: The image displayed by the first-generation PS is inferior to that of the MD in contrast and resolution measures, but it is comparable in the other image qualities. No significant differences in task performance were identified. Conclusions: The first-generation PS does not confer performance or comfort advantages over an MD. The theoretical advantages of the gaze-down stance are likely to be realized only if a high-quality projector is used.
引用
收藏
页码:586 / 590
页数:5
相关论文
共 11 条
[1]
Breedveld P, 2001, MINIM INVASIV THER, V10, P155
[2]
COMPARISON OF DIRECT VISION AND ELECTRONIC 2-DIMENSIONAL AND 3-DIMENSIONAL DISPLAY SYSTEMS ON SURGICAL TASK EFFICIENCY IN ENDOSCOPIC SURGERY [J].
CROSTHWAITE, G ;
CHUNG, T ;
DUNKLEY, P ;
SHIMI, S ;
CUSCHIERI, A .
BRITISH JOURNAL OF SURGERY, 1995, 82 (06) :849-851
[3]
Visual display technology for endoscopic surgery [J].
Cuschieri, A .
MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 1996, 5 (05) :427-434
[5]
CUSCHIERI A, 1995, SEMIN LAPAROSC SURG, V2, P209
[6]
Dancey C.P. Reidy., 1999, STAT MATHS PSYCHOL
[7]
Influence of the optical axis-to-target view angle on endoscopic task performance [J].
Hanna, GB ;
Cuschieri, A .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1999, 13 (04) :371-375
[8]
Task performance in endoscopic surgery is influenced by location of the image display [J].
Hanna, GB ;
Shimi, SM ;
Cuschieri, A .
ANNALS OF SURGERY, 1998, 227 (04) :481-484
[9]
Human sense of vision: A guide to future endoscopic imaging systems [J].
Schurr, MO ;
Buess, G ;
Kunert, W ;
Flemming, E ;
Hermeking, H ;
Gumb, L .
MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 1996, 5 (05) :410-418
[10]
Schwaitzberg S D, 2001, Semin Laparosc Surg, V8, P3, DOI 10.1053/slas.2001.23654