Clinical use of polyethylene glycols as marker substances and determination in urine by liquid chromatography

被引:18
作者
Gauchel, G
Huppertz, B
Feiertag, H
Keller, R
机构
[1] Kliniken Stadt Koln, Zent Lab, D-51109 Cologne, Germany
[2] Gesundheitsamt Dusseldorf, Drogenambulanz, D-40235 Dusseldorf, Germany
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2003年 / 787卷 / 02期
关键词
poly(ethylene glycol);
D O I
10.1016/S1570-0232(02)00925-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Adulteration of samples is a serious problem in the analysis of drugs of abuse. One of the most frequent methods is substitution of urines by "clean" urines to gain false-negative results in laboratory tests for drugs of abuse. One way to approach this problem may be to label the patient's urine with marker substances which are given orally prior to the delivery of urine. This concept is based on methods for determining malabsorption in pediatric medicine. We report a protocol for evaluating low-molecular-mass polyethylene glycols as enteral labelling marker substances. For monitoring renal excretion of the ingested polyethylene glycols we have developed and optimised an isocratic reversed-phase high-performance liquid chromatographic method with automatic sample cleanup by column switching in the back-flush technique and with RI detection. The chromatographic procedure is simple, reliable and rapid, allowing a high sample throughput for routine screening. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:271 / 279
页数:9
相关论文
共 30 条
[1]   ESTIMATION OF POLYETHYLENEGLYCOLS IN HUMAN-URINE FOR STUDIES OF INTESTINAL-ABSORPTION [J].
BAKER, RWR ;
FERRETT, J .
JOURNAL OF CHROMATOGRAPHY, 1983, 273 (02) :421-425
[2]   SIMPLE METHOD FOR GAS-LIQUID-CHROMATOGRAPHIC ANALYSIS OF POLYETHYLENGLYCOL 400 IN BIOLOGICAL-FLUIDS [J].
BOUSKA, JB ;
PHILLIPS, SF .
JOURNAL OF CHROMATOGRAPHY, 1980, 183 (01) :72-77
[3]  
CHADWICK VS, 1977, GASTROENTEROLOGY, V73, P247
[4]  
CHADWICK VS, 1977, GASTROENTEROLOGY, V73, P241
[5]   SIZE EXCLUSION CHROMATOGRAPHIC DETERMINATION OF PEG-3350 IN HUMAN-PLASMA AND URINE [J].
CLARK, BA ;
DIPIRO, JT ;
CADWALLADER, DE .
ANALYTICAL LETTERS, 1987, 20 (02) :293-301
[6]  
DELAHUNTY T, 1986, CLIN CHEM, V32, P351
[7]   Determination of low levels of poly(ethylene glycol) 400 in plasma and urine by capillary gas chromatography-selected ion-monitoring mass spectrometry after solid-phase extraction [J].
Fakt, C ;
Ervik, M .
JOURNAL OF CHROMATOGRAPHY B, 1997, 700 (1-2) :93-100
[8]   INTESTINAL PERMEABILITY IN HEALTHY AND ALLERGIC CHILDREN BEFORE AND AFTER SODIUM-CROMOGLYCATE TREATMENT ASSESSED WITH DIFFERENT-SIZED POLYETHYLENEGLYCOLS (PEG-400 AND PEG-1000) [J].
FALTHMAGNUSSON, K ;
KJELLMAN, NIM ;
MAGNUSSON, KE ;
SUNDQVIST, T .
CLINICAL ALLERGY, 1984, 14 (03) :277-286
[9]  
IRVING CS, 1986, J LAB CLIN MED, V107, P290
[10]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF PEG-600 IN HUMAN URINE [J].
KINAHAN, IM ;
SMYTH, MR .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 565 (1-2) :297-307