摘要
Background: The aim of this study was to investigate reproducibility and accuracy of computer-assisted coronary plaque measurements by multislice computed tomography coronary angiography (QMSCT-CA). Methods and Results: Forty-eight patients undergoing MSCT-CA and coronary arteriography for symptomatic coronary artery disease and quantitative intravascular ultrasound (IVUS, QCU) were examined. Two investigators performed the QMSCT-CA twice and a third investigator performed the QCU, all blinded for each other's results. There was no difference found for the matched region of interest (ROI) lengths (OCU 29.4 +/- 13 mm vs. QMSCT-CA 29.6 +/- 13 mm, P = 0.6; total length = 1,400 mm). The comparison of volumetric measurements showed (lumen QCU 267 +/- 139 mm 3 vs. mean QMSCT-CA 177 +/- 91 mm(3), P < 0.001; vessel 454 < 194 mm(3) vs. 398 +/- 187 mm 3, P < 0.001; and plaque 189 +/- 93 mm(3) vs. 222 +/- 121 mm(3); investigator 1, P = 0.02; and investigator 2, P = 0.07) significant differences. Automated lumen detection was also applied for QMSCT-CA (218 +/- 112 mm(3), p < 0.001 vs. QCU). The interinvestigator variability measurements for QMSCT-CA showed no significant differences. Conclusion: QMSCT-CA systematically underestimates absolute coronary lumen- and vessel dimensions when compared with OCU. However, repeated measurements of coronary plaque by QMSCT-CA showed no statistically significant differences, although, the outcome showed a scattered result. Automated lumen detection for QMSCT-CA showed improved results when compared with those of human investigators. (c) 2007Wiley-Liss, Inc.
引用
收藏
页码:857 / 865
页数:9
相关论文
共 29 条
[1]   Detection of calcified and noncalcified coronary atherosclerotic plaque by contrast-enhanced, submillimeter multidetector spiral computed tomography - A segment-based comparison with intravascular ultrasound [J].
Achenbach, S ;
Moselewski, F ;
Ropers, D ;
Ferencik, M ;
Hoffmann, U ;
MacNeill, B ;
Pohle, K ;
Baum, U ;
Anders, K ;
Jang, I ;
Daniel, WG ;
Brady, TJ .
CIRCULATION, 2004, 109 (01) :14-17
[2]   STATISTICS NOTES .1. CORRELATION, REGRESSION, AND REPEATED DATA [J].
BLAND, JM ;
ALTMAN, DG .
BRITISH MEDICAL JOURNAL, 1994, 308 (6933) :896-896
[3]  
Bruining N, 1998, CATHETER CARDIO DIAG, V43, P254, DOI 10.1002/(SICI)1097-0304(199803)43:3<254::AID-CCD3>3.0.CO
[4]  
2-8
[5]   Adjustment method for mechanical Boston scientific corporation 30 MHz intravascular ultrasound catheters connected to a Clearview® console -: Mechanical 30 MHz IVUS Catheter Adjustment [J].
Bruining, N ;
Hamers, R ;
Teo, TJ ;
de Feijter, PJ ;
Serruys, PW ;
Roelandt, JRTC .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2004, 20 (02) :83-91
[6]   Characterization of vulnerable nonstenotic plaque with 16-slice computed tomography compared with intravascular sound [J].
Caussin, C ;
Ohanessian, A ;
Ghostine, S ;
Jacq, L ;
Lancelin, B ;
Dambrin, G ;
Sigal-Cinqualbre, A ;
Angel, CY ;
Paul, JF .
AMERICAN JOURNAL OF CARDIOLOGY, 2004, 94 (01) :99-104
[7]   Retrospective image-based gating of intracoronary ultrasound images for improved quantitative analysis: The intelligate method [J].
de Winter, SA ;
Hamers, R ;
Degertekin, M ;
Tanabe, K ;
Lemos, PA ;
Serruys, PW ;
Roelandt, JRTC ;
Bruining, N .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 61 (01) :84-94
[8]   A novel approach to quantitative analysis of intra vascular ultrasound images [J].
Hamers, R ;
Bruining, N ;
Knook, M ;
Sabate, M ;
Roelandt, JRTC .
COMPUTERS IN CARDIOLOGY 2001, VOL 28, 2001, 28 :589-592
[9]  
Hodgson J M, 1990, Echocardiography, V7, P403, DOI 10.1111/j.1540-8175.1990.tb00381.x
[10]   Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation [J].
Jakobs, TF ;
Becker, CR ;
Ohnesorge, B ;
Flohr, T ;
Suess, C ;
Schoepf, UJ ;
Reiser, MF .
EUROPEAN RADIOLOGY, 2002, 12 (05) :1081-1086