Determination of psilocin in magic mushrooms and rat plasma by liquid chromatography with fluorimetry and electrospray ionization mass spectrometry

被引:21
作者
Saito, K
Toyo'oka, T
Fukushima, T
Kato, M
Shirota, O
Goda, Y
机构
[1] Univ Shizuoka, COE Program 21st Century, Sch Pharmaceut Sci, Shizuoka 4228526, Japan
[2] Natl Inst Hlth Sci, Div Pharmacognosy & Phytochem, Setagaya Ku, Tokyo 1588501, Japan
关键词
psilocin; magic mushroom; rat plasma; HPLC-FL; HPLC-ESI-MS; selective-ion monitoring;
D O I
10.1016/j.aca.2004.08.071
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The sensitive determination of psilocin was carried out by reversed-phase liquid chromatography (HPLC) coupled with fluorimetry (FL) and electrospray ionization mass spectrometry (ESI-MS). Psilocin and bufotenine, used as an internal standard (IS), were labeled with excess amounts of 4-(N,N-dimethylaminosulfonyl)-7-(2-chloroformylpyrrolidin-1-yl)-2,1,3-benzoxadiazole (DBD-Pro-COCl) at 60degreesC for 10min in the presence of pyridine as the scavenger of HCl produced in the solution. The resulting derivatives were separated by a Mightysil RP-18 GP column (150mm x 4.6mm, i.d., 3 mum) with an acidic mobile-phase containing 0.1% trifluoroacetic acid (TFA) and detected at 560nm (excitation at 440 nm). Under the conditions for derivatization, separation and detection, a good linearity of the calibration curve of psilocin was observed by the HPLC-FL method. On the other hand, the derivative, separated by a Mightysil RP-18 GP (100 mm x 2.0 mm, i.d., 3 mum) using 50 mM AcONH4-CH3CN (73:27), was also determined by HPLC-ESI-MS. The mass spectrometer was operated in the selected-ion monitoring (SIM) mode for the protonated-molecular ion [M + H](+) (m/z = 527). The calibration curve in the SIM mode was also linear in the range of 0.16-4.08 ng psilocin, similar to the HPLC-FL method. The coefficient of variation (CV) was 5.15% (0.16 ng injection, n = 6). The quantitation limit was 0.64 ng/mg dried mushroom. The amounts of psilocin in six magic mushrooms using HPLC-MS were lower than 12.67 ng/mg samples. The developed method was also successfully applied to the determination of psilocin in rat plasma after a single i.p. administration of psilocybin. The proposed method provides good precision and trace detection of psilocin in actual samples, suggesting that these analytical techniques are usable for the determination of psilocin in various specimens. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:149 / 156
页数:8
相关论文
共 24 条
[1]  
BENKERT O, 1992, PSYCHIAT PHARMAKOTHE
[2]   Liquid chromatography-mass spectrometry as a routine method in forensic sciences: a proof of maturity [J].
Bogusz, MJ .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2000, 748 (01) :3-19
[3]  
BORNER S, 1992, J CHROMATOGR, V593, P201
[4]   DETERMINATION OF PSILOCYBIN IN PSILOCYBE-SEMILANCEATA USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ON A SILICA COLUMN [J].
CHRISTIANSEN, AL ;
RASMUSSEN, KE ;
TONNESEN, F .
JOURNAL OF CHROMATOGRAPHY, 1981, 210 (01) :163-167
[5]  
Grieshaber AF, 2001, J FORENSIC SCI, V46, P627
[6]   Total resolution of 17 DL-amino acids labelled with a fluorescent chiral reagent, R(-)-4-(3-isothiocyanatopyrrolidin-1-yl)-7-(N,N-dimethylaminosulfonyl)-2,1,3-benzoxadiazole, by high-performance liquid chromatography [J].
Jin, DR ;
Nagakura, K ;
Murofushi, S ;
Miyahara, T ;
Toyo'oka, T .
JOURNAL OF CHROMATOGRAPHY A, 1998, 822 (02) :215-224
[7]   DETERMINATION OF PSILOCIN IN RAT URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION [J].
KYSILKA, R .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 534 :287-290
[8]   Quantitation of psilocin in human plasma by high-performance liquid chromatography and electrochemical detection:: comparison of liquid-liquid extraction with automated on-line solid-phase extraction [J].
Lindenblatt, H ;
Krämer, E ;
Holzmann-Erens, P ;
Gouzoulis-Mayfrank, E ;
Kovar, KA .
JOURNAL OF CHROMATOGRAPHY B, 1998, 709 (02) :255-263
[9]   ENANTIOMETRIC SEPARATION OF DI-PEPTIDES AND TRI-PEPTIDES WITH CHIRAL FLUORESCENCE LABELING REAGENTS BY LIQUID-CHROMATOGRAPHY [J].
LIU, YM ;
MIAO, JR ;
TOYOOKA, T .
ANALYTICA CHIMICA ACTA, 1995, 314 (03) :169-173
[10]  
Menser GP, 1997, HALLUCINOGENIC POISO