Characteristics of the adsorption of immunoglobulin M onto Q Sepharose® Fast Flow ion-exchangers

被引:7
作者
Chase, HA [1 ]
Machielse, B [1 ]
Naveh, D [1 ]
机构
[1] Univ Cambridge, Dept Chem Engn, Cambridge CB2 3RA, England
关键词
effective diffusivities; immunoglobulin M; isotherms; protein purification; Sepharose Fast Flow;
D O I
10.1023/A:1008042032753
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Measurement of adsorption breakthrough curves in packed beds has shown that the amounts and rates of uptake of immunoglobulin M (IgM) onto the commonly used anionic ion-exchanger Q Sepharose Fast Flow (based on 6% agarose) are severely limited as a result of the large molecular size of this adsorbate (RMM 950 000). A similar ion-exchanger based on a more porous 4% agarose, Q Sepharose 4 Fast Flow was evaluated as an alternative adsorbent for the purification of IgM. Equilibrium adsorption isotherms and the effective diffusivities of IgM within these two adsorbents were measured. Q-Sepharose 4 Fast Flow was found to have a maximum capacity for IgM 2.5 times greater than that of Q Sepharose 6 Fast Flow and the effective diffusivity of IgM was found to be between 6 and 7 times greater than with the latter material. Comparison of the breakthrough curves obtained for these adsorbents at a variety of flow velocities confirm that Q Sepharose 4 Fast Flow is a superior adsorbent for the capture and purification of large proteins.
引用
收藏
页码:47 / 55
页数:9
相关论文
共 28 条
[1]  
Anspach FB, 1996, BIOSEPARATION, V6, P165
[2]   MODELING AND ANALYSIS OF BIOSPECIFIC ADSORPTION IN A FINITE BATH [J].
ARVE, BH ;
LIAPIS, AI .
AICHE JOURNAL, 1987, 33 (02) :179-193
[3]   LIQUID-CHROMATOGRAPHY MODELING - A REVIEW [J].
BELLOT, JC ;
CONDORET, JS .
PROCESS BIOCHEMISTRY, 1991, 26 (06) :363-376
[4]   NONLINEAR FIXED-BED SORPTION WHEN MASS-TRANSFER AND SORPTION ARE CONTROLLING [J].
BIYANI, P ;
GOOCHEE, CF .
AICHE JOURNAL, 1988, 34 (10) :1747-1751
[5]  
BOGARD WC, 1993, J IMMUNOL, V150, P4438
[6]   PREDICTION OF THE PERFORMANCE OF PREPARATIVE AFFINITY-CHROMATOGRAPHY [J].
CHASE, HA .
JOURNAL OF CHROMATOGRAPHY, 1984, 297 (AUG) :179-202
[7]   MODELING METHODS TO AID THE DESIGN AND OPTIMIZATION OF BATCH STIRRED-TANK AND PACKED-BED COLUMN ADSORPTION AND CHROMATOGRAPHY UNITS [J].
COWAN, GH ;
GOSLING, IS ;
SWEETENHAM, WP .
JOURNAL OF CHROMATOGRAPHY, 1989, 484 :187-210
[8]  
COWAN GH, 1986, J CHROMATOGR, V363, P37
[9]   A CONTROLLED CLINICAL-TRIAL OF E5 MURINE MONOCLONAL IGM ANTIBODY TO ENDOTOXIN IN THE TREATMENT OF GRAM-NEGATIVE SEPSIS [J].
GREENMAN, RL ;
SCHEIN, RMH ;
MARTIN, MA ;
WENZEL, RP ;
MACINTYRE, NR ;
EMMANUEL, G ;
CHMEL, H ;
KOHLER, RB ;
MCCARTHY, M ;
PLOUFFE, J ;
RUSSELL, JA .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1991, 266 (08) :1097-1102
[10]   THE PURIFICATION AND CHARACTERIZATION OF CERVINE IGM AND IGG [J].
HIBMA, MH ;
GRIFFIN, JFT .
VETERINARY IMMUNOLOGY AND IMMUNOPATHOLOGY, 1990, 26 (04) :343-352