Distribution of bone quality in patients receiving endosseous dental implants

被引:113
作者
Truhlar, RS
Orenstein, IH
Morris, HF
Ochi, S
机构
[1] Vet Affairs Med Ctr, Dent Implant Clin Res Grp, Ann Arbor, MI 48105 USA
[2] Vet Affairs Med Ctr, Northport, NY USA
[3] SUNY Stony Brook, Sch Dent Med, Dept Periodont, Stony Brook, NY 11794 USA
[4] Vet Affairs Med Ctr, Dent Implant Clin Res Grp, Bronx, NY USA
[5] Columbia Univ, Sch Dent & Oral Surg, New York, NY 10027 USA
[6] Vet Affairs Med Ctr, Dent Clin Res Ctr, Ann Arbor, MI 48105 USA
关键词
D O I
10.1016/S0278-2391(16)31196-X
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Knowledge of the distribution of bone quality in the various jaw regions assists the clinician in dental implant treatment planning, Bone quality was assessed with radiographs and tactile sensation for 2,839 implants at the time of placement into four anatomic regions of the jaw, The Lekholm-Zarb classification system was used, Overall, bone quality types 1 and 4 were found much less frequently than types 2 and 3, Although variations in density existed in each region, quality 2 bone dominated the mandible, and quality 3 bone was more prevalent in the maxilla. For both anterior and posterior jaw regions, types 2 and 3 bone predominated. The anterior mandible had the densest bone, followed by the posterior mandible, anterior maxilla, and posterior maxilla.
引用
收藏
页码:38 / 45
页数:8
相关论文
共 33 条
[1]  
ADELL R, 1985, TISSUE INTEGRATED PR, P211
[2]   OSSEOINTEGRATED TITANIUM IMPLANTS - REQUIREMENTS FOR ENSURING A LONG-LASTING, DIRECT BONE-TO-IMPLANT ANCHORAGE IN MAN [J].
ALBREKTSSON, T ;
BRANEMARK, PI ;
HANSSON, HA ;
LINDSTROM, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02) :155-170
[3]  
[Anonymous], 1993, Contemporary Implant Dentistry
[4]  
ARPAK N, 1995, J DENT RES, V74, P414
[5]  
Bahat O, 1993, Int J Oral Maxillofac Implants, V8, P151
[6]  
BASS SL, 1991, INT J ORAL MAXILLOF, V6, P193
[7]   FATIGUE BEHAVIOR OF ADULT CORTICAL BONE - THE INFLUENCE OF MEAN STRAIN AND STRAIN RANGE [J].
CARTER, DR ;
CALER, WE ;
SPENGLER, DM ;
FRANKEL, VH .
ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (05) :481-490
[8]   MECHANICAL LOADING HISTORIES AND CORTICAL BONE REMODELING [J].
CARTER, DR .
CALCIFIED TISSUE INTERNATIONAL, 1984, 36 :S19-S24
[9]   CYCLE-DEPENDENT AND TIME-DEPENDENT BONE-FRACTURE WITH REPEATED LOADING [J].
CARTER, DR ;
CALER, WE .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1983, 105 (02) :166-170
[10]  
Engquist B, 1988, Int J Oral Maxillofac Implants, V3, P129