Second-order advantage achieved with four-way fluorescence excitation-emission-kinetic data processed by parallel factor analysis and trilinear least-squares.: Determination of methotrexate and leucovorin in human urine

被引:101
作者
Olivieri, AC
Arancibia, JA
de la Peña, AM
Durán-Merás, I
Mansilla, AE
机构
[1] Univ Nacl Rosario, Fac Ciencias Bioquim & Farmaceut, Dept Quim Analit, RA-2000 Rosario, Argentina
[2] Univ Extremadura, Fac Ciencias, Dept Quim Analit, E-06071 Badajoz, Spain
关键词
D O I
10.1021/ac0493065
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Four-way fluorescence data recorded by following the kinetic evolution of excitation-emission fluorescence matrices (EEMs) have been analyzed by parallel factor analysis and trilinear least-squares algorithms. These methodologies exploit the second-order advantage of the studied data, allowing analyte concentrations to be estimated even in the presence of an uncalibrated fluorescent background. They were applied to the simultaneous determination of the components of the anticancer combination of methotrexate and leucovorin in human urine samples. Both analytes were converted into highly fluorescent compounds by oxidation with potassium permanganate, and the kinetics of the reaction was continuously monitored by recording full EEM of the samples at different reaction times. A commercial fast scanning spectrofluorometer has been used for the first time to measure the four-way EEM kinetic data. The rapid scanning instrument allows the acquisition of a complete EEM in 12 s at a wavelength scanning speed of 24 000 nm/min. The emission spectra were recorded from 335 to 490 nm at 5-nm intervals, exciting from 255 to 315 nm at 6-nm intervals. Ten successive EEMs were measured at 72-s intervals, to follow the fluorescence kinetic evolution of the mixture components. Good recoveries were obtained in synthetic binary samples and also in spiked urine samples. The excitation, emission, and kinetic time profiles recovered by both chemometric techniques are in good agreement with experimental observations.
引用
收藏
页码:5657 / 5666
页数:10
相关论文
共 65 条
[1]   Practical aspects of PARAFAC modeling of fluorescence excitation-emission data [J].
Andersen, CM ;
Bro, R .
JOURNAL OF CHEMOMETRICS, 2003, 17 (04) :200-215
[2]  
[Anonymous], 1998, Multi-way Analysis in the Food Industry: Models, Algorithms and Applications
[3]  
[Anonymous], [No title captured]
[4]   First- and second-order multivariate calibration applied to biological samples: determination of anti-inflammatories in serum and urine [J].
Arancibia, JA ;
Olivieri, AC ;
Escandar, GM .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 374 (03) :451-459
[5]   Two different strategies for the fluorimetric determination of piroxicam in serum [J].
Arancibia, JA ;
Escandar, GM .
TALANTA, 2003, 60 (06) :1113-1121
[6]   Three-way multivariate calibration procedures applied to high-performance liquid chromatography coupled with fast-scanning fluorescence spectrometry detection.: Determination of polycyclic aromatic hydrocarbons in water samples [J].
Beltrán, JL ;
Guiteras, J ;
Ferrer, R .
ANALYTICAL CHEMISTRY, 1998, 70 (09) :1949-1955
[7]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF METHOTREXATE, 7-HYDROXYMETHOTREXATE, 5-METHYLTETRAHYDROFOLIC ACID AND FOLINIC ACID IN SERUM AND CEREBROSPINAL-FLUID [J].
BELZ, S ;
FRICKEL, C ;
WOLFROM, C ;
NAU, H ;
HENZE, G .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 661 (01) :109-118
[8]   THEORY OF ANALYTICAL-CHEMISTRY [J].
BOOKSH, KS ;
KOWALSKI, BR .
ANALYTICAL CHEMISTRY, 1994, 66 (15) :A782-A791
[9]   Multivariate detection limits with fixed probabilities of error [J].
Boqué, R ;
Larrechi, MS ;
Rius, FX .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1999, 45 (1-2) :397-408
[10]   Limit of detection estimator for second-order bilinear calibration [J].
Boqué, R ;
Ferré, J ;
Faber, NM ;
Rius, FX .
ANALYTICA CHIMICA ACTA, 2002, 451 (02) :313-321