Development and validation for high selective quantitative determination of metformin in human plasma by cation exchanging with normal-phase LC/MS/MS

被引:85
作者
Koseki, N [1 ]
Kawashita, H [1 ]
Niina, M [1 ]
Nagae, Y [1 ]
Masuda, N [1 ]
机构
[1] Novartis Pharma KK, Tsukuba Res Inst, Tsukuba, Ibaraki 3002611, Japan
关键词
cation exchange solid-phase extraction; normal-phase; cation exchange HPLC; LC/MS/MS; metformin; NIDDM; combination therapy;
D O I
10.1016/j.jpba.2004.09.007
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An assay based on cation exchange solid-phase extraction and liquid chromatography-tandem mass spectrometry (LC/MS/MS) has been developed for the quantitative determination of metformin in human plasma. The analytical method consists of cation exchange solid-phase extraction (VersaPlate CBA) without any further evaporation/dissolution steps and cation exchange-based HPLC separation (Capcell Pak SCX column) with a normal-phase gradient system followed by semi-micro LC/MS/MS in positive ion selected reaction monitoring mode using electrospray ionization. The method exhibited excellent performance in terms of selectivity, robustness, short run time (7 min/sample) and simplicity of sample preparation. The calibration range was 10-1000 ng/ml with 0.2 ml of plasma. Intra- and inter-day mean accuracies were within the. ranges of 100.3-105.0% and 101.2-105.3%. respectively. Intra- and inter-day precisions were within the ranges of 0.8-1.9% and 1.5-8.6% respectively. Mean absolute recovery was 67.0% for metformin. No apparent loss of metformin after extraction was observed in an autosampler at 10degreesC for 24 h. Dilution of metformin by blank human plasma up to 20-fold was tested and revealed no impact on the results of determination. Furthermore. the method exhibited high selectivity, since no effect on metformin analysis was observed on comparison of samples with or without nateglinide and other agents in plasma. Results obtained with the method were also comparable to a published LC-UV method on cross-validation. This method can be applied to various clinical pharmacokinetic studies of metformin. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:1063 / 1072
页数:10
相关论文
共 30 条
[1]   Determination of metformin in plasma using a new ion pair solid phase extraction technique and ion pair liquid chromatography [J].
AbuRuz, S ;
Millership, J ;
McElnay, J .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 798 (02) :203-209
[2]   Drug therapy - Metformin [J].
Bailey, CJ ;
Turner, RC .
NEW ENGLAND JOURNAL OF MEDICINE, 1996, 334 (09) :574-579
[3]   DETERMINATION OF METFORMIN AND PHENFORMIN IN HUMAN-PLASMA AND URINE BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BENZI, L ;
MARCHETTI, P ;
CECCHETTI, P ;
NAVALESI, R .
JOURNAL OF CHROMATOGRAPHY, 1986, 375 (01) :184-189
[4]   Rapid determination of metformin in human plasma by liquid chromatography-tandem mass spectrometry method [J].
Chen, XY ;
Gu, Q ;
Qiu, F ;
Zhong, DF .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 802 (02) :377-381
[5]   Determination of metformin in human plasma by high-performance liquid chromatography with spectrophotometric detection [J].
Cheng, CL ;
Chou, CH .
JOURNAL OF CHROMATOGRAPHY B, 2001, 762 (01) :51-58
[6]   Glyburide/metformin tablets: a new therapeutic option for the management of Type 2 diabetes [J].
Dailey, GE .
EXPERT OPINION ON PHARMACOTHERAPY, 2003, 4 (08) :1417-1430
[7]  
Di Cicco RA, 2000, J CLIN PHARMACOL, V40, P1280
[8]   Pharmacokinetics and pharmacodynamics of glyburide/metformin tablets (Glucovance™) versus equivalent doses of glyburide and metformin in patients with type 2 diabetes [J].
Donahue, SR ;
Turner, KC ;
Patel, S .
CLINICAL PHARMACOKINETICS, 2002, 41 (15) :1301-1309
[9]  
FONCECA V, 2000, JAMA-J AM MED ASSOC, V283, P1695
[10]   Fast liquid chromatographic-tandem mass spectrometric (LC-MS-MS) determination of metformin in plasma samples [J].
Heinig, K ;
Bucheli, F .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 34 (05) :1005-1011