Evaluation of a dried blood spot HIV-1 RNA program for early infant diagnosis and viral load monitoring at rural and remote healthcare facilities

被引:79
作者
Lofgren, Sarah M. [1 ]
Morrissey, Anne B. [1 ]
Chevallier, Caroline C. [1 ,2 ]
Malabeja, Anangisye I. [5 ]
Edmonds, Sally [6 ]
Amos, Ben [6 ]
Sifuna, David J. [3 ]
von Seidlein, Lorenz [7 ]
Schimana, Werner [3 ]
Stevens, Wendy S. [8 ,9 ]
Bartlett, John A. [1 ,2 ]
Crump, John A. [1 ,2 ,3 ,4 ]
机构
[1] Duke Univ, Med Ctr, Dept Med, Div Infect Dis & Int Hlth, Durham, NC 27710 USA
[2] Duke Univ, Duke Global Hlth Inst, Durham, NC 27710 USA
[3] Tumaini Univ, Kilimanjaro Christian Med Ctr, Moshi, Tanzania
[4] Tumaini Univ, Kilimanjaro Christian Med Coll, Moshi, Tanzania
[5] Magunga Hosp, Korogwe, Tanzania
[6] Hosp Teule, Muheza, Tanzania
[7] Joint Malaria Programme, Tanga, Tanzania
[8] Univ Witwatersrand, Dept Mol Med & Haematol, Sch Pathol, Fac Hlth Sci, Parktown, South Africa
[9] Natl Hlth Lab Serv, Parktown, South Africa
关键词
blood specimen collection; diagnosis; HIV; laboratory techniques and procedures; reverse transcriptase PCR; Tanzania; IMMUNODEFICIENCY-VIRUS RNA; INFECTION; PLASMA; ASSAYS; DNA; PERFORMANCE;
D O I
10.1097/QAD.0b013e328331f702
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Objective: To assess technical and operational performance of a dried blood spot (DBS)-based HIV-1 RNA service for remote healthcare facilities in a low-income country. Design: A method comparison and operational evaluation of DBS RNA against conventional tests for early infant diagnosis of HIV and HIV RNA quantitation under field conditions in Tanzania. Methods: DBSs were prepared and plasma was frozen at -80 degrees C. DBSs were mailed and plasma couriered to a central laboratory for testing using the Abbott m2000 system. Infant diagnosis DBSs were also tested for HIV-1 DNA by ROCHE COBAS AmpliPrep/COBAS TaqMan System. Results of DBS RNA were compared with conventional tests; program performance was described. Results: Among 176 infant diagnosis participants, using a threshold of at least 1000 copies/ml, sensitivity and specificity of DBS versus plasma RNA were 1.00 and 0.99, and of DBS RNA versus DBS DNA were 0.97 and 1.00. Among 137 viral load monitoring participants, when plasma and DBS RNA were compared, r value was 0.9709; r value was 0.9675 for at least 5000 copies/ml but was 0.7301 for less than 5000 copies/ml. The highest plasma RNA value at which DBS RNA was not detected was 2084 copies/ml. Median (range) turnaround time from sample collection to result receipt at sites was 23 (4-69) days. The Tanzania mail service successfully transmitted all DBS and results between sites and the central laboratory. Conclusion: Under program conditions in Tanzania, DBS provided HIV-1 RNA results comparable to conventional methods to remote healthcare facilities. DBS RNA testing is an alternative to liquid plasma for HIV-1 RNA services in remote areas. (C) 2009 Wolters Kluwer Health | Lippincott Williams & Wilkins
引用
收藏
页码:2459 / 2466
页数:8
相关论文
共 27 条
[1]  
[Anonymous], 2004, NAT ANT TREATM GUID
[2]  
[Anonymous], 2009, PRIOR INT HIV AIDS P
[3]   Can routine clinical markers be used longitudinally to monitor antiretroviral therapy success in resource-limited settings? [J].
Bagchi, Shashwatee ;
Kempf, Mirjam C. ;
Westfall, Andrew O. ;
Maherya, Anastasiya ;
Willig, James ;
Saag, Michael S. .
CLINICAL INFECTIOUS DISEASES, 2007, 44 (01) :135-138
[4]   Multicenter evaluation of use of dried blood and plasma spot specimens in quantitative assays for human immunodeficiency virus RNA: Measurement, precision, and RNA stability [J].
Brambilla, D ;
Jennings, C ;
Aldrovandi, G ;
Bremer, J ;
Comeau, AM ;
Cassol, SA ;
Dickover, R ;
Jackson, JB ;
Pitt, J ;
Sullivan, JL ;
Butcher, A ;
Grosso, L ;
Reichelderfer, P ;
Fiscus, SA .
JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (05) :1888-1893
[5]   CLEARANCE OF HIV-INFECTION IN A PERINATALLY INFECTED INFANT [J].
BRYSON, YJ ;
PANG, S ;
WEI, LS ;
DICKOVER, R ;
DIAGNE, A ;
CHEN, ISY .
NEW ENGLAND JOURNAL OF MEDICINE, 1995, 332 (13) :833-838
[6]   HIV viral load monitoring in resource-limited regions: Optional or necessary? [J].
Calmy, Alexandra ;
Ford, Nathan ;
Hirschel, Bernard ;
Reynolds, Steven J. ;
Lynen, Lut ;
Goemaere, Eric ;
de la Vega, Felipe Garcia ;
Perrin, Luc ;
Rodriguez, William .
CLINICAL INFECTIOUS DISEASES, 2007, 44 (01) :128-134
[7]   Comparison of human immunodeficiency virus 1 DNA polymerase chain reaction and qualitative and quantitative RNA polymerase chain reaction in human immunodeficiency virus 1-exposed infants [J].
Cunningham, CK ;
Charbonneau, TT ;
Song, KM ;
Patterson, D ;
Sullivan, T ;
Cummins, T ;
Poiesz, B .
PEDIATRIC INFECTIOUS DISEASE JOURNAL, 1999, 18 (01) :30-35
[8]   HIV-1 RNA detection in plasma for the diagnosis of infection in neonates [J].
Delamare, C ;
Burgard, M ;
Mayaux, MJ ;
Blanche, S ;
Doussin, A ;
Ivanoff, S ;
Chaix, ML ;
Khan, C ;
Rouzioux, C ;
Akapko ;
Allemon ;
Allisy ;
Armengaud ;
Aufrant ;
Babinet ;
BaderMeunier ;
Balde ;
Baruchel ;
Benichou ;
Bensadoun ;
Berterottiere ;
Blanchard ;
Boddaert ;
Bompard ;
Botto ;
Boulley ;
Braive ;
Brault ;
Broyart ;
Brunner ;
Cacault ;
Carlus ;
Chalvon ;
Ciraru ;
Clemencet ;
Cohen ;
ColinGorski ;
Crumiere ;
Dallot ;
Dandine ;
DeCrepy ;
DeGennes ;
Deberdt ;
Debons ;
Debre ;
Denavit ;
Devidas ;
Donadieu ;
Dubois ;
Dumontel .
JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES AND HUMAN RETROVIROLOGY, 1997, 15 (02) :121-125
[9]   Altitude-dependent and -independent variations in Plasmodium falciparum prevalence in northeastern Tanzania [J].
Drakeley, CJ ;
Carneiro, I ;
Reyburn, H ;
Malima, R ;
Lusingu, JPA ;
Cox, J ;
Theander, TG ;
Nkya, WMMM ;
Lemnge, MM ;
Riley, EM .
JOURNAL OF INFECTIOUS DISEASES, 2005, 191 (10) :1589-1598
[10]   Dynamics of HIV viremia and antibody seroconversion in plasma donors: implications for diagnosis and staging of primary HIV infection [J].
Fiebig, EW ;
Wright, DJ ;
Rawal, BD ;
Garrett, PE ;
Schumacher, RT ;
Peddada, L ;
Heldebrant, C ;
Smith, R ;
Conrad, A ;
Kleinman, SH ;
Busch, MP .
AIDS, 2003, 17 (13) :1871-1879