Midterm experience with the Jarvik 2000 axial flow left ventricular assist device

被引:48
作者
Haj-Yahia, Saleem
Birks, Emma J.
Rogers, Paula
Bowles, Christopher
Hipkins, Mandy
George, Robert
Amrani, Mohammed
Petrou, Mario
Pepper, John
Dreyfus, Gilles
Khaghani, Asghar
机构
[1] Royal Brompton & Harefield Hosp, Dept Cardiothorac Transplantat & Mech Circulatory, London, England
[2] Imperial Coll, Natl Heart & Lung Inst, London, England
关键词
D O I
10.1016/j.jtcvs.2007.01.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Rotary axial flow pumps have several potential advantages and disadvantages over pulsatile pumps. The Jarvik 2000 is distinctive in being intracardiac. We report our experience in 22 patients. Methods: The Jarvik 2000 was implanted in 15 men and 7 women. Mean age was 38.8 (range 23-59) years, preoperative diagnosis was dilated cardiomyopathy in 16, postpartum cardiomyopathy in 3, ischemic heart disease in 2, and chronic allograft failure in 1. Twenty-one patients were in New York Heart Association class IV, and 1 patient was in class III. Nineteen patients were on inotropic support, 6 were supported with an intra-aortic balloon pump, and 2 patients had been salvaged with a Centrimag (Levitronix) ventricular assist device. The median pulmonary vascular resistance was 3 Wood units; median pulmonary capillary wedge pressure was 26.6 mm Hg; and mean Cardiac Index was 1.5 L/min/m(2). Results: There were 2 early deaths and 6 late deaths. The average postoperative ventilation time and Intensive Treatment Unit stay was 2.2 and 10 days, respectively. One patient required a right ventricular assist device for short-term support and another for medium-term support. Seven patients were bridged to transplant, 3 had myocardial recovery, and 4 are ongoing. Mean and total duration of support was 280.5 and 6172 days, respectively. Driveline failures were noted in 3, but there were no pump infections or failure. Conclusion: The Jarvik 2000 provides satisfactory intermediate-term results as a bridge to transplant or recovery. It appears to be associated with a low rate of serious driveline or pump infections and technical failure. However, bleeding complications due to the required anticoagulation treatment frequently occurred.
引用
收藏
页码:199 / 203
页数:5
相关论文
共 25 条
[1]  
[Anonymous], 2004, Technol Eval Cent Assess Program Exec Summ, V19, P1
[2]   Incidence and clinical management of life-threatening left ventricular assist device failure [J].
Birks, EJ ;
Tansley, PD ;
Yacoub, MH ;
Bowles, CT ;
Hipkin, M ;
Hardy, J ;
Banner, NR ;
Khaghani, A .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2004, 23 (08) :964-969
[3]  
Cooley DA, 2002, CIRCULATION, V105, P2808, DOI 10.1161/01.CIR.0000021162.19008.F9
[4]   Cardiac replacement with a total artificial heart as a bridge to transplantation [J].
Copeland, JG ;
Smith, RG ;
Arabia, FA ;
Nolan, PE ;
Sethi, GK ;
Tsau, PH ;
McClellan, D ;
Slepian, MJ ;
Foy, B ;
Long, J ;
Doty, D ;
Tector, A ;
Kormos, R .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 351 (09) :859-867
[5]   Mechanical Circulatory Support device database of the International Society for Heart and Lung Transplantation: Second Annual Report-2004 [J].
Deng, MC ;
Edwards, LB ;
Hertz, MI ;
Rowe, AW ;
Keck, BM ;
Kormos, R ;
Naftel, DC ;
Kirklin, JK .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2004, 23 (09) :1027-1034
[6]   Mechanical circulatory support for advanced heart failure - Where does it stand in 2003? [J].
Frazier, OH ;
Delgado, RM .
CIRCULATION, 2003, 108 (25) :3064-3068
[7]   Initial clinical experience with the Jarvik 2000 implantable axial-flow left ventricular assist system [J].
Frazier, OH ;
Myers, TJ ;
Gregoric, ID ;
Khan, T ;
Delgado, R ;
Croitoru, M ;
Miller, K ;
Jarvik, R ;
Westaby, S .
CIRCULATION, 2002, 105 (24) :2855-2860
[8]  
Frazier OH, 2003, ANN SURG, V237, P631, DOI 10.1097/00000658-200305000-00005
[9]   Worldwide experience with the MicroMed DeBakey ventricular assist device® as a bridge to transplantation [J].
Goldstein, DJ .
CIRCULATION, 2003, 108 (10) :272-277
[10]   First experiences with a novel magnetically suspended axial flow left ventricular assist device [J].
Hetzer, R ;
Weng, YG ;
Potapov, EV ;
Pasic, M ;
Drews, T ;
Jurmann, M ;
Hennig, E ;
Müller, J .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2004, 25 (06) :964-970