Dual-phase 3D MDCT angiography for evaluation of the liver before hepatic resection

被引:37
作者
Stemmler, BJ
Paulson, EK
Thornton, FJ
Winters, SR
Nelson, RC
Clary, BM
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
[2] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
[3] Duke Univ, Med Ctr, Dept Surg, Durham, NC 27710 USA
关键词
D O I
10.2214/ajr.183.6.01831551
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. We sought to evaluate the accuracy of dual-phase MDCT angiography for assessing the liver before hepatic resection and to compare 2D and 3D images for quality and arterial branch visualization. MATERIALS AND METHODS. Sixty-three patients with colorectal metastases (n 30), hepatocellular carcinomas (n = 13), giant hemangiomas (n = 5), and other lesions (it = 15) underwent dual-phase MDCT using either a LightSpeed QX/i 4-MDCT (n = 31) or LightSpeed QX/i Ultra 8-MDCT (n = 32) scanner. Contrast material (150 mL of Isovue 370 [iopamidol]) was injected at a rate of 5 mL/sec. The arterial phase images were rendered on a workstation to obtain 3D MDCT angiograms that were assessed by two reviewers who were blinded to the surgical findings. Arterial anatomy was categorized according to the Michels classification. The reviewers assessed the 2D and 3D images for quality, arterial branch visualization, and differences between the 4- and 8-MDCT images. In the 43 patients who underwent resection, imaging findings were correlated with intraoperative findings. RESULTS. The anatomy of hepatic arteries in the 63 patients was classified as follows: Michels type I, 51 patients (80.9%); type III, four patients (6.3%); type V, five patients (7.9%); and types VII, VIII, and IX, one patient (1.6%) each. In 40 (93%) of 43 patients, the surgical findings concurred with MDCT findings. Three discrepancies were due to failure to identify small accessory left hepatic arteries. Branch visualization and image quality of the 2D images were superior to those of the 3D images. No significant difference was found between the 4- and 8-MDCT images in branch visualization and image quality. CONCLUSION. Three-dimensional MDCT angiography is accurate for classification of hepatic arterial anatomy before hepatic resection. Although 2D data sets show small arteries to better advantage than 3D MDCT angiograms, the 3D MDCT angiograms provide a useful overview of hepatic anatomy.
引用
收藏
页码:1551 / 1557
页数:7
相关论文
共 25 条
[1]   Accuracy and utility of 3-dimensional computed tomography in evaluating donors for adult living related liver transplants [J].
Bogetti, JD ;
Herts, BR ;
Sands, MJ ;
Carroll, JF ;
Vogt, DP ;
Henderson, JM .
LIVER TRANSPLANTATION, 2001, 7 (08) :687-692
[2]  
CURLEY SA, 1993, SURGERY, V114, P928
[3]   Multi-detector row CT of relevant vascular anatomy of the surgical plane in split-liver transplantation [J].
Guiney, MJ ;
Kruskal, JB ;
Sosna, J ;
Hanto, DW ;
Goldberg, SN ;
Raptopoulos, V .
RADIOLOGY, 2003, 229 (02) :401-407
[4]   Optimization of eight-element multi-detector row helical CT technology for evaluation of the abdomen [J].
Gupta, AK ;
Nelson, RC ;
Johnson, GA ;
Paulson, EK ;
Delong, DM ;
Yoshizumi, TT .
RADIOLOGY, 2003, 227 (03) :739-745
[5]   SURGICAL ANATOMY OF THE HEPATIC ARTERIES IN 1000 CASES [J].
HIATT, JR ;
GABBAY, J ;
BUSUTTIL, RW .
ANNALS OF SURGERY, 1994, 220 (01) :50-52
[6]   Multidetector CT arteriography with volumetric three-dimensional rendering to evaluate patients with metastatic colorectal disease for placement of a floxuridine infusion pump [J].
Kapoor, V ;
Brancatelli, G ;
Federle, MP ;
Katyal, S ;
Marsh, JW ;
Geller, DA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (02) :455-463
[7]   Hepatic arterial infusion of chemotherapy after resection of hepatic metastases from colorectal cancer. [J].
Kemeny, N ;
Huang, Y ;
Cohen, AM ;
Shi, WJ ;
Conti, JA ;
Brennan, MF ;
Bertino, JR ;
Turnbull, ADM ;
Sullivan, D ;
Stockman, J ;
Blumgart, LH ;
Fong, YM .
NEW ENGLAND JOURNAL OF MEDICINE, 1999, 341 (27) :2039-2048
[8]   Hepatic arteries in potential donors for living related liver transplantation: Evaluation with multi-detector row CT angiography [J].
Lee, SS ;
Kim, TK ;
Byun, JH ;
Ha, HK ;
Kim, PN ;
Kim, AY ;
Lee, SG ;
Lee, MG .
RADIOLOGY, 2003, 227 (02) :391-399
[9]  
Michels N.A., 1955, BLOOD SUPPLY ANATOMY