Evaluation of automated fundus photograph analysis algorithms for detecting microaneurysms, haemorrhages and exudates, and of a computer-assisted diagnostic system for grading diabetic retinopathy

被引:58
作者
Dupas, B. [1 ]
Walter, T. [2 ]
Erginay, A. [1 ]
Ordonez, R. [2 ]
Deb-Joardar, N. [3 ]
Gain, P. [3 ]
Klein, J. -C. [2 ]
Massin, P. [1 ]
机构
[1] Univ Denis Diderot Paris 7, Hop Lariboisiere, AP HP, Serv Ophtalmol, F-75010 Paris, France
[2] Mines Paristech, Ctr Morphol Math CMM Math & Syst, F-77305 Fontainebleau, France
[3] Univ Hosp Bellevue, Serv Ophtalmol, St Etienne, France
关键词
Diabetic retinopathy; Macular edema; Fundus photography; Screening; Automated image analysis; RETINAL IMAGES; RED LESIONS; DISEASE; IDENTIFICATION; POPULATION;
D O I
10.1016/j.diabet.2010.01.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims. - This study aimed to evaluate automated fundus photograph analysis algorithms for the detection of primary lesions and a computer-assisted diagnostic system for grading diabetic retinopathy (DR) and the risk of macular edema (ME). Methods. - Two prospective analyses were conducted on fundus images from diabetic patients. Automated detection of microaneurysms and exudates was applied to two small image databases on which these lesions were manually marked. A computer-assisted diagnostic system for the detection and grading of DR and the risk of ME was then developed and evaluated, using a large database containing both normal and pathological images, and compared with manual grading. Results. - The algorithm for the automated detection of microaneurysms demonstrated a sensitivity of 88.5%, with an average number of 2.13 false positives per image. The pixel-based evaluation of the algorithm for automated detection of exudates had a sensitivity of 92.8% and a positive predictive value of 92.4%. Combined automated grading of DR and risk of ME was performed on 761 images from a large database. For DR detection, the sensitivity and specificity of the algorithm were 83.9% and 72.7%, respectively, and, for detection of the risk of ME, the sensitivity and specificity were 72.8% and 70.8%, respectively. Conclusion. - This study shows that previously published algorithms for computer-aided diagnosis is a reliable alternative to time-consuming manual analysis of fundus photographs when screening for DR. The use of this system would allow considerable timesavings for physicians and, therefore, alleviate the time spent on a mass-screening programme. (C) 2010 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:213 / 220
页数:8
相关论文
共 37 条
[1]   Evaluation of a System for Automatic Detection of Diabetic Retinopathy From Color Fundus Photographs in a Large Population of Patients With Diabetes [J].
Abramoff, Michael D. ;
Niemeijer, Meindert ;
Suttorp-Schulten, Maria S. A. ;
Viergever, Max A. ;
Russell, Stephen R. ;
van Ginneken, Bram .
DIABETES CARE, 2008, 31 (02) :193-198
[2]  
*AM AC OPHTH RET P, 2008, PREF PRACT PATT DIAB
[3]  
[Anonymous], 1990, Diabet Med, V7, P360
[4]  
[Anonymous], 1981, OPHTHALMOLOGY, V88, P583
[5]  
[Anonymous], 1983, Image Analysis and Mathematical Morphology
[6]   Automated detection of diabetic retinopathy: Results of a screening study [J].
Bouhaimed, Manal ;
Gibbins, Robbie ;
Owens, David .
DIABETES TECHNOLOGY & THERAPEUTICS, 2008, 10 (02) :142-148
[7]   Prevalence of diabetic eye disease in an inner city population: the Liverpool Diabetic Eye Study [J].
Broadbent, DM ;
Scott, JA ;
Vora, JP ;
Harding, SP .
EYE, 1999, 13 (2) :160-165
[8]   AUTOMATED DIAGNOSIS OF RETINOPATHY BY CONTENT-BASED IMAGE RETRIEVAL [J].
Chaum, Edward ;
Karnowski, Thomas P. ;
Govindasamy, V. Priya ;
Abdelrahman, Mohamed ;
Tobin, Kenneth W. .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2008, 28 (10) :1463-1477
[9]  
*CNAMTS, 2004, RAPP DEM OPHT 2000 2
[10]   Screening for diabetic retinopathy in France [J].
Deb, N ;
Thuret, G ;
Estour, B ;
Massin, P ;
Gain, P .
DIABETES & METABOLISM, 2004, 30 (02) :140-145