Temperature and energy performance of refrigerated retail display and commercial catering cabinets under test conditions

被引:56
作者
Evans, J. A. [1 ]
Scarcelli, S. [1 ]
Swain, M. V. L. [1 ]
机构
[1] Univ Bristol, FRPERC, Bristol BS40 5DU, Avon, England
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2007年 / 30卷 / 03期
关键词
refrigeration; commercial application; display cabinet; test; measurement; performance; temperature; energy consumption;
D O I
10.1016/j.ijrefrig.2006.10.006
中图分类号
O414.1 [热力学];
学科分类号
摘要
An analysis of the performance of well freezers, chest freezers, frozen and chilled door cabinets (solid or glass door) and open fronted chilled cabinets under EN441 test conditions demonstrated that maximum temperatures in cabinets were generally in the most exposed (to ambient) areas and that minimum temperatures were located in the least exposed areas. Detailed positions of maximum and minimum temperature varied between cabinet types. In chest freezers 95% of the maximum temperature positions were located in the top layer and 95% of the minimum temperature positions were located in the middle layer of the cabinets. In full door frozen cabinets the maximum temperature position was in the majority of cases on the top shelf (64%) with most maximum packs being at the front of the top shelf (53%). In the chilled full door cabinets 94% of the maximum temperature packs were situated at the front of the cabinet. In open fronted cabinets the majority of maximum temperature packs (97%) were located at the front of the cabinet, the largest number (60%) being at the front of the base of the cabinet. In well cabinets the majority of maximum temperature packs (81%) were located in the top layer of the cabinet and the majority (91%) of minimum temperature packs were located in the bottom of the cabinet. Large differences in energy consumed by cabinets of similar size and temperature performance were found indicating that large reductions in energy and CO2 emissions could be achieved by selection of the most efficient cabinets. (c) 2006 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:398 / 408
页数:11
相关论文
共 12 条
[1]  
BRIMELOW CJB, 1987, TEMPERATURE TIME TEM
[2]  
Faramarzi R., 2003, ASHRAE T RES, P267
[3]   The temperatures and ages of packs of beef displayed in multi-shelf retail cabinets [J].
Gill, CO ;
Jones, T ;
Houde, A ;
LeBlanc, DI ;
Rahn, K ;
Holley, RA ;
Starke, R .
FOOD CONTROL, 2003, 14 (03) :145-151
[4]  
GORMLEY TR, 1987, MINUTES COST 91 BIS
[5]   EVALUATION OF THE BACTERIOLOGICAL CONSEQUENCES OF THE TEMPERATURE REGIMES EXPERIENCED BY FRESH CHILLED MEAT DURING RETAIL DISPLAY [J].
GREER, GG ;
GILL, CO ;
DILTS, BD .
FOOD RESEARCH INTERNATIONAL, 1994, 27 (04) :371-377
[6]  
JAMES SJ, 1990, CHILLED FOODS REVOLU, V3, P3273
[7]  
Magnussen O. M., 1983, P 14 IIR C PAR, P453
[8]  
OLSSON P, 1990, CHILLED FOODS REVOLU, V3, P3279
[9]  
ROGERS RW, 1980, RESULTS PROCESSED ME
[10]  
Rose C, 1984, P IFST SCOTT BRANCH, P69