Turbulent and transitional velocity measurements in a rectangular microchannel using microscopic particle image velocimetry

被引:43
作者
Li, H [1 ]
Ewoldt, RH [1 ]
Olsen, MG [1 ]
机构
[1] Iowa State Univ, Dept Mech Engn, Ames, IA 50011 USA
基金
美国国家科学基金会;
关键词
turbulence; transition; microchannel; MicroPIV;
D O I
10.1016/j.expthermflusci.2004.06.001
中图分类号
O414.1 [热力学];
学科分类号
摘要
Microscopic particle image velocimetry (microPIV) experiments were performed on a polydimethylsiloxane (PDMS) microchannel with a cross-section measuring 320 mum x 330 mum for Reynolds numbers between 272 and 2853. Care was taken to ensure that the seed particle density was great enough that accurate instantaneous velocity vector fields could be obtained for all the Reynolds numbers investigated. Velocity fluctuations were calculated from ensembles of microPIV velocity fields. The <u'>/u(max) fluctuation showed an increase at Re = 1535 and a further increase as Reynolds numbers were increased, suggesting that transition to turbulence began near Re = 1535, a Reynolds number lower than predicted by classical theory. The <u'>/u(max) data also suggest the flow was fully developed at a Reynolds number between 2630 and 2853, also lower than classical results. This finding was confirmed in plots of the mean velocity profile. For the fully developed flow, the measured <u'>/u(max) fluctuation agreed well with classical results for turbulent duct flow, but the <u'>/u(max) fluctuation was 25-40% lower than turbulent duct flow results. Finally, spatial correlations of velocity fluctuations were calculated to lend some insights into the characteristics of the large-scale turbulent structures observed in the turbulent microchannel flow. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:435 / 446
页数:12
相关论文
共 38 条
[1]   Microfabricated polymer devices for automated sample delivery of peptides for analysis by electrospray ionization tandem mass spectrometry [J].
Chan, JH ;
Timperman, AT ;
Qin, D ;
Aebersold, R .
ANALYTICAL CHEMISTRY, 1999, 71 (20) :4437-4444
[2]  
CHUNG PMY, 2002, FED, V257, P1219
[3]  
Devasenathipathy S, 2003, EXP FLUIDS, V34, P504, DOI [10.1007/S00348-003-0588-Y, 10.1007/S00348-003-0588-y]
[4]   Molding of deep polydimethylsiloxane microstructures for microfluidics and biological applications [J].
Folch, A ;
Ayon, A ;
Hurtado, O ;
Schmidt, MA ;
Toner, M .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1999, 121 (01) :28-34
[5]  
GUI F, 1995, P 30 INT EN CONV ENG, V2, P289
[6]   Size effect on microscale single-phase flow and heat transfer [J].
Guo, ZY ;
Li, ZX .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2003, 46 (01) :149-159
[7]   Size effect on single-phase channel flow and heat transfer at microscale [J].
Guo, ZY ;
Li, ZX .
INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2003, 24 (03) :284-298
[8]   Developing convective heat transfer in deep rectangular microchannels [J].
Harms, TM ;
Kazmierczak, MJ ;
Gerner, FM .
INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 1999, 20 (02) :149-157
[9]   Friction and convection studies of R-134a in microchannels within the transition and turbulent flow regimes [J].
Hegab, HE ;
Bari, A ;
Ameel, T .
EXPERIMENTAL HEAT TRANSFER, 2002, 15 (04) :245-259
[10]  
Islam MS, 2002, EXP FLUIDS, V33, P296, DOI [10.1007/S00348-002-0432-9, 10.1007/s00348-002-0432-9]