Ferrocene branched chitosan for the construction of a reagentless amperometric hydrogen peroxide biosensor

被引:46
作者
Garcia, Ariel
Peniche-Covas, Carlos
Chico, Belkis
Simpson, Benjamin K.
Villalonga, Reynaldo
机构
[1] Univ Matanzas, Ctr Enzyme Technol, Matanzas 44740, Cuba
[2] Univ Havana, Ctr Biomat, Havana 10400, Cuba
[3] McGill Univ, Food Sci & Agr Chem Dept, Ste Anne De Bellevue, PQ H9X 3V9, Canada
关键词
biosensors; chitosan; immobilized enzymes; polysaccharides;
D O I
10.1002/mabi.200700032
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Chitosan was chemically branched with ferrocene moieties and further used as a support for the immobilization of horseradish peroxidase on a glassy carbon electrode. The reagentless biosensor device showed a linear amperometric response toward hydrogen peroxide concentrations between 35 X 10(-6) M and 2.0 x 10(-3) M. The biosensor reached 95% of the steady-state current in about 20 s and its sensitivity was 28.4 x 10(-3) mu A.M-1. The enzyme electrode retained 94% of its initial activity after 2 weeks of storage at 4 degrees C in 50 x 10(-3) M sodium phosphate buffer at pH 7.0.
引用
收藏
页码:435 / 439
页数:5
相关论文
共 29 条
[1]   Redox hydrogel based bienzyme electrode for L-glutamate monitoring [J].
Belay, A ;
Collins, A ;
Ruzgas, T ;
Kissinger, PT ;
Gorton, L ;
Csöregi, E .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 19 (1-2) :93-105
[2]   ENZYME CATALYSIS AT HYDROGEL-MODIFIED ELECTRODES WITH REDOX POLYMER MEDIATOR [J].
CALVO, EJ ;
DANILOWICZ, C ;
DIAZ, L .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS, 1993, 89 (02) :377-384
[3]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[4]   Biotinylated alginate immobilization matrix in the construction of an amperometric biosensor: application for the determination of glucose [J].
Cosnier, S ;
Novoa, A ;
Mousty, C ;
Marks, RS .
ANALYTICA CHIMICA ACTA, 2002, 453 (01) :71-79
[5]   Electrode coatings based on chitosan scaffolds [J].
Cruz, J ;
Kawasaki, M ;
Gorski, W .
ANALYTICAL CHEMISTRY, 2000, 72 (04) :680-686
[6]   Urea biosensors based on immobilization of urease into two oppositely charged clays (Laponite and Zn-Al layered double hydroxides) [J].
de Melo, JV ;
Cosnier, S ;
Mousty, C ;
Martelet, C ;
Jaffrezic-Renault, N .
ANALYTICAL CHEMISTRY, 2002, 74 (16) :4037-4043
[7]   A METHOD FOR ESTIMATION OF HYDROGEN-PEROXIDE BASED ON MEDIATED ELECTRON-TRANSFER REACTIONS OF PEROXIDASES AT ELECTRODES [J].
FREW, JE ;
HARMER, MA ;
HILL, HAO ;
LIBOR, SI .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1986, 201 (01) :1-10
[8]   Electrochemistry and electrocatalysis with heme proteins in chitosan biopolymer films [J].
Huang, H ;
Hu, NF ;
Zeng, YH ;
Zhou, G .
ANALYTICAL BIOCHEMISTRY, 2002, 308 (01) :141-151
[9]   Enzyme stabilization using pectin as a novel entrapment matrix in biosensors [J].
Jawaheer, S ;
White, SF ;
Rughooputh, SDDV ;
Cullen, DC .
ANALYTICAL LETTERS, 2002, 35 (13) :2077-2091
[10]  
KURITA K, 1977, MAKROMOL CHEM, V178, P3197