Sensitive determination of rhodamine 110-labeled monosaccharides in glycoprotein by capillary electrophoresis with laser-induced fluorescence detection

被引:16
作者
Ijiri, Soichiro [1 ,2 ]
Todoroki, Kenichiro [1 ]
Yoshida, Hideyuki [1 ]
Yoshitake, Takashi [3 ]
Nohta, Hitoshi [1 ]
Yamaguchi, Masatoshi [1 ]
机构
[1] Fukuoka Univ, Fac Pharmaceut Sci, Johnan Ku, Fukuoka 8140180, Japan
[2] Int Univ Hlth & Welf, Sch Pharm, Ohtawara, Tochigi 3248501, Japan
[3] Karolinska Inst, Dept Physiol & Pharmacol, SE-17177 Stockholm, Sweden
关键词
Rhodamine; 110; Derivatization Monosaccharides; Capillary electrophoresis with; laser-induced fluorescence detection; PERFORMANCE LIQUID-CHROMATOGRAPHY; ANION-EXCHANGE CHROMATOGRAPHY; HAMSTER OVARY CELLS; QUANTITATIVE-DETERMINATION; ZONE-ELECTROPHORESIS; SUGAR CHAIN; OLIGOSACCHARIDES; 2-AMINOACRIDONE; DERIVATIZATION; DERIVATIVES;
D O I
10.1016/j.chroma.2010.02.076
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
Rhodamine 110 (Rho110) has been used in the highly sensitive analysis of monosaccharides, as it reacts with the reducing carbonyl group of the saccharides. The monosaccharide derivatives were investigated by capillary electrophoresis with laser-induced fluorescence detection. The derivatization was performed at 90 degrees C for 30 min for all monosaccharides. The derivatized monosaccharides were separated using 200 mM borate (pH 10.5) as running buffer within 20 min. The fluorescence intensities of Rho110-derivatives were significantly decreased by the presence of excess reducing agent, but were greatly increased by the addition of potassium hexacyanoferrate(III). The concentration and mass detection limits for monosaccharides were in the range of 1.4-2.8 nM and 36-70 amol, respectively. We have applied this derivatization method to the analysis of the composition of monosaccharides in glycoproteins (ribonuclease B, fetuin, and erythropoietin) following their subjection to strong acid hydrolysis. The results from these analyses were in good agreements with the reported values established previously. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:3161 / 3166
页数:6
相关论文
共 39 条
[1]
RAPID QUANTITATIVE-DETERMINATION OF SIALIC ACIDS IN GLYCOPROTEINS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH A SENSITIVE FLUORESCENCE DETECTION [J].
ANUMULA, KR .
ANALYTICAL BIOCHEMISTRY, 1995, 230 (01) :24-30
[2]
QUANTITATIVE-DETERMINATION OF MONOSACCHARIDES IN GLYCOPROTEINS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH HIGHLY SENSITIVE FLUORESCENCE DETECTION [J].
ANUMULA, KR .
ANALYTICAL BIOCHEMISTRY, 1994, 220 (02) :275-283
[3]
ANALYSIS OF GLYCOPROTEIN-DERIVED OLIGOSACCHARIDES BY HIGH-PH ANION-EXCHANGE CHROMATOGRAPHY [J].
BASA, LJ ;
SPELLMAN, MW .
JOURNAL OF CHROMATOGRAPHY, 1990, 499 :205-220
[4]
BERNARD BA, 1983, J BIOL CHEM, V258, P2198
[5]
A dual-detection strategy in the chromatographic analysis of 2-aminoacridone-derivatized oligosaccharides [J].
Birrell, H ;
Charlwood, J ;
Lynch, I ;
North, S ;
Camilleri, P .
ANALYTICAL CHEMISTRY, 1999, 71 (01) :102-108
[6]
Quantitative analysis of sugar constituents of glycoproteins by capillary electrophoresis [J].
Chen, FTA ;
Dobashi, TS ;
Evangelista, RA .
GLYCOBIOLOGY, 1998, 8 (11) :1045-1052
[7]
ANALYSIS OF MONOSACCHARIDE AND OLIGOSACCHARIDE ISOMERS DERIVATIZED WITH 9-AMINOPYRENE-L,4,6-TRISULFONATE BY CAPILLARY ELECTROPHORESIS WITH LASER-INDUCED FLUORESCENCE [J].
CHEN, FTA ;
EVANGELISTA, RA .
ANALYTICAL BIOCHEMISTRY, 1995, 230 (02) :273-280
[8]
New noncellular fluorescence microplate screening assay for scavenging activity against singlet oxygen [J].
Costa, David ;
Fernandes, Eduarda ;
Santos, Joao L. M. ;
Pinto, Diana C. G. A. ;
Silva, Artur M. S. ;
Lima, Jose L. F. C. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (06) :2071-2081
[9]
Drexhage K. H., 1977, DYE LASERS, P144
[10]
Acid-catalyzed reductive amination of aldoses with 8-aminopyrene-1,3,6-trisulfonate [J].
Evangelista, RA ;
Guttman, A ;
Chen, FTA .
ELECTROPHORESIS, 1996, 17 (02) :347-351