Change in peripherally inserted central catheter tip position with abduction and adduction of the upper extremity

被引:107
作者
Forauer, AR [1 ]
Alonzo, M [1 ]
机构
[1] St Louis Univ, Hlth Sci Ctr, Dept Radiol, St Louis, MO 63103 USA
关键词
catheters and catheterization; central venous access; veins; extremities; heart; arrhythmia;
D O I
10.1016/S1051-0443(07)61308-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: This study examines whether the tip of peripherally inserted central catheters (PICCs) moves significantly with changes in arm position from abduction to adduction, MATERIALS AND METHODS: The catheters were inserted in the brachial or basilic veins under ultrasonographic guidance with the upper extremity in a 90 degrees abducted position, A flexible, radiopaque ruler was then placed on the anterior chest and digital images were obtained with the arm abducted and adducted in a similar phase of quiet respiration. Catheter tip movement was measured with use of the radiopaque ruler and fixed, bony anatomic landmarks, RESULTS: Sixty-one consecutive PICCs were placed and evaluated during the study period (eight patients were excluded). Thirty-three catheters were placed from the right arm and 20 from the left. Overall, 43 moved caudally, seven moved cephalad, and three did not move with movement of the arm from abduction to adduction, Of those that moved caudal, the meals distance of movement was 21 mm (range, 2-53 mm), Right arm PICCs tended to move more than left arm PICCs, but this did not attain significance (P = .29), CONCLUSIONS: There is a tendency for the PICC tip to move in a caudal direction with the change in arm position from abduction to adduction; 58% of PICCs moved 20 mm or more. This change in position should be considered during final catheter tip positioning.
引用
收藏
页码:1315 / 1318
页数:4
相关论文
共 16 条
[1]   MECHANISM OF PERFORATION OF HEART WITH PRODUCTION OF HYDROPERICARDIUM BY A VENOUS CATHETER AND ITS PREVENTION [J].
BRANDT, RL ;
FOLEY, WJ ;
FINK, GH ;
REGAN, WJ .
AMERICAN JOURNAL OF SURGERY, 1970, 119 (03) :311-&
[2]   Cumulative experience with 1,273 peripherally inserted central catheters at a single institution [J].
Cardella, JF ;
Cardella, K ;
Bacci, N ;
Fox, PS ;
Post, JH .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1996, 7 (01) :5-13
[3]   DISPLACEMENT OF CATHETERS INSERTED THROUGH INTERNAL JUGULAR VEINS WITH NECK FLEXION AND EXTENSION - A PRELIMINARY-STUDY [J].
CURELARU, I ;
LINDER, LE ;
GUSTAVSSON, B .
INTENSIVE CARE MEDICINE, 1980, 6 (03) :179-183
[4]   COMPLICATIONS OF INDWELLING VENOUS ACCESS DEVICES IN CANCER-PATIENTS [J].
EASTRIDGE, BJ ;
LEFOR, AT .
JOURNAL OF CLINICAL ONCOLOGY, 1995, 13 (01) :233-238
[5]   Migration of central venous catheters: Implications for initial catheter tip positioning [J].
Kowalski, CM ;
Kaufman, JA ;
Rivitz, SM ;
Geller, SC ;
Waltman, AC .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1997, 8 (03) :443-447
[6]  
LEE DS, 1984, ANESTH ANALG, V63, P949
[7]   Changes in tunneled catheter tip position when a patient is upright [J].
Nazarian, GK ;
Bjarnason, H ;
Dietz, CA ;
Bernadas, CA ;
Hunter, DW .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1997, 8 (03) :437-441
[8]  
PUEL V, 1993, CANCER, V72, P2248, DOI 10.1002/1097-0142(19931001)72:7<2248::AID-CNCR2820720731>3.0.CO
[9]  
2-U
[10]  
SCHWAB S, 1997, AM J KIDNEY DIS S, V30, P150