Microbial adhesion to poly(ethylene oxide) brushes: Influence of polymer chain length and temperature

被引:193
作者
Roosjen, A
van der Mei, HC
Busscher, HJ
Norde, W
机构
[1] Univ Groningen, Dept Biomed Engn, NL-9713 AV Groningen, Netherlands
[2] Univ Wageningen & Res Ctr, Lab Phys Chem & Colloid Sci, NL-6703 HB Wageningen, Netherlands
关键词
D O I
10.1021/la048469l
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Glass surfaces were modified by end-grafting poly(ethylene oxide) (PEO) chains having molecular weights of 526,2000, or 9800 Da. Characterization using water contact angles, ellipsometry, and X-ray photoelectron spectroscopy confirmed the presence of the PEO brushes on the surface with estimated lengths in water of 2.8-, 7.5-, and 23.7-nm, respectively. Adhesion of two bacterial (Staphylococcus epidermidis and Pseudomonas aeruginosa) and two yeast (Candida albicans and Candida tropicalis) strains to these brushes was studied and compared to their adhesion to bare glass. For the bacterium P. aeruginosa and the yeast C. tropicalis, adhesion to the 2.8-nm brush was comparable to their adhesion on bare glass, whereas adhesion to the 7.5- and 23.7-nm brushes was greatly reduced. For S. epidermidis, adhesion was only slightly higher to the 2.8-nm brush than that to the longer brushes. Adhesion of the yeast C. albicans to the PEO brushes was lower than that to glass, but no differences in adhesion were found between the three brush lengths. After passage of an air bubble, nearly all microorganisms adhering to a brush were removed, irrespective of brush length, whereas retention of the adhering organisms on glass was much higher. No significant differences were found in adhesion nor retention between experiments conducted at 20 and those conducted at 37 degreesC.
引用
收藏
页码:10949 / 10955
页数:7
相关论文
共 56 条
[1]  
Andrade J.D., 1985, SURFACE INTERFACIAL, P105, DOI [DOI 10.1007/978-1-4684-8610-0_5, 10.1007/978-1-4684-8610-0_5]
[2]  
[Anonymous], 2004, ALDR HDB FIN CHEM LA
[3]   Polyelectrolyte multilayer films with pegylated polypeptides as a new type of anti-microbial protection for biomaterials [J].
Boulmedais, F ;
Frisch, B ;
Etienne, O ;
Lavalle, P ;
Picart, C ;
Ogier, J ;
Voegel, JC ;
Schaaf, P ;
Egles, C .
BIOMATERIALS, 2004, 25 (11) :2003-2011
[4]  
Busscher HJ, 1997, J BIOMED MATER RES, V34, P201, DOI 10.1002/(SICI)1097-4636(199702)34:2<201::AID-JBM9>3.0.CO
[5]  
2-U
[6]  
BUSSCHER HJ, 1995, METHOD ENZYMOL, V253, P455
[7]  
BUSSCHER HJ, 1987, FEMS MICROBIOL LETT, V46, P165, DOI 10.1111/j.1574-6968.1987.tb02457.x
[8]   Tethered polymer chains: surface chemistry and their impact on colloidal and surface properties [J].
Currie, EPK ;
Norde, W ;
Stuart, MAC .
ADVANCES IN COLLOID AND INTERFACE SCIENCE, 2003, 100 :205-265
[9]   12-crown-4-ether and tri(ethylene glycol) dimethyl-ether plasma-coated stainless steel surfaces and their ability to reduce bacterial biofilm deposition [J].
Denes, AR ;
Somers, EB ;
Wong, ACL ;
Denes, F .
JOURNAL OF APPLIED POLYMER SCIENCE, 2001, 81 (14) :3425-3438
[10]   SURFACE-IMMOBILIZED POLYETHYLENE OXIDE FOR BACTERIAL REPELLENCE [J].
DESAI, NP ;
HOSSAINY, SFA ;
HUBBELL, JA .
BIOMATERIALS, 1992, 13 (07) :417-420