Strain adaptive bone remodelling in total joint replacement

被引:16
作者
Draenert, KD
Draenert, YL
Krauspe, R
Bettin, D
机构
[1] Zentrum Orthopad Wissensch, D-81545 Munich, Germany
[2] Univ Dusseldorf, D-4000 Dusseldorf, Germany
[3] Marien Hosp, Papenburg, Germany
关键词
D O I
10.1097/01.blo.0000150424.59854.7b
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Histomorphologic analyses of artificial joint components implanted into bone need special technology for processing and for documentation; published histological work systematically done therefore is rare. The histopathology, three-dimensionally analyzed in a complete sequence of sections is, however, the only precise answer in terms of biocompatibility and bone response. A complete analysis allows a type-related predictable prognosis of an implantation that is at least comparable to a finite element analysis with respect to load transfer to host bone. The histopathologic collection of the ZOW Munich is comprised of more than 5000 nondemineralized bone and joint specimens and more than 500 artificial joint components implanted in the human skeleton for up to 25 years. Fifty-nine implant-bone specimens without signs of loosening already have been processed and analyzed systematically. According to the strain-adapted bone remodelling, different types of anchorage clearly were differentiated and their morphologic substrate could be worked out. Based on that, the cemented standard anchorage could be distinguished histologically from the cemented press-fit procedure, and the noncemented press-fit from the porous ingrowths pattern. In terms of the topography of the bony integration, the proximal and distal press-fit and ingrowth pattern were analyzed; beside that, the cemented and noncemented epiphyseal resurfacings could be defined histologically. In all histologic specimens the remodelling appeared as a result of stress-related strain, reflecting stiffness of the implant and the resistance of bone to deformation. It clearly was worked out that all success of cemented components is based on preserved cancellous bone honeycombs stiffened by bone cement, representing an adaptation of bone in terms of stiffness to the stiff implants.
引用
收藏
页码:12 / 27
页数:16
相关论文
共 140 条
[1]
TREATMENT OF PRIMARY OSTEOARTHRITIS OF THE HIP - A COMPARISON OF TOTAL JOINT AND SURFACE REPLACEMENT ARTHROPLASTY [J].
AMSTUTZ, HC ;
THOMAS, BJ ;
JINNAH, R ;
KIM, W ;
GROGAN, T ;
YALE, C .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (02) :228-241
[2]
PRECISION-FIT SURFACE HEMIARTHROPLASTY FOR FEMORAL-HEAD OSTEONECROSIS - LONG-TERM RESULTS [J].
AMSTUTZ, HC ;
GRIGORIS, P ;
SAFRAN, MR ;
GRECULA, MJ ;
CAMPBELL, PA ;
SCHMALZRIED, TP .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (03) :423-427
[3]
FEMORAL-HEAD PROSTHESES - A REVIEW OF 356 OPERATIONS AND THEIR RESULTS [J].
ANDERSON, LD ;
HAMSA, WR ;
WARING, TL .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1964, 46 (05) :1049-1065
[4]
[Anonymous], GESETZ TRANSFORMATIO
[6]
BALLARD WT, 1994, J BONE JOINT SURG AM, V76A, P959
[7]
TOTAL HIP ARTHROPLASTY - REVIEW OF 333 CASES WITH LONG FOLLOW-UP [J].
BECKENBAUGH, RD ;
ILSTRUP, DM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1978, 60 (03) :306-313
[8]
A STUDY OF IMPLANT FAILURE IN THE WAGNER RESURFACING ARTHROPLASTY [J].
BELL, RS ;
SCHATZKER, J ;
FORNASIER, VL ;
GOODMAN, SB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (08) :1165-1175
[9]
THE EFFECT OF FEMORAL STEM GEOMETRY ON INTERFACE MOTION IN UNCEMENTED POROUS-COATED TOTAL HIP PROSTHESES - COMPARISON OF STRAIGHT-STEM AND CURVED-STEM DESIGNS [J].
CALLAGHAN, JJ ;
FULGHUM, CS ;
GLISSON, RR ;
STRANNE, SK .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (06) :839-848
[10]
THE UNCEMENTED POROUS-COATED ANATOMIC TOTAL HIP-PROSTHESIS - 2-YEAR RESULTS OF A PROSPECTIVE CONSECUTIVE SERIES [J].
CALLAGHAN, JJ ;
DYSART, SH ;
SAVORY, CG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (03) :337-346