Carotid Intraplaque Hemorrhage Imaging at 3.0-T MR Imaging: Comparison of the Diagnostic Performance of Three T1-weighted Sequences

被引:158
作者
Ota, Hideki [1 ]
Yarnykh, Vasily L. [1 ]
Ferguson, Marina S. [1 ]
Underhill, Hunter R. [1 ]
DeMarco, J. Kevin [1 ]
Zhu, David C. [1 ]
Oikawa, Minako [1 ]
Dong, Li [1 ]
Zhao, Xihai [1 ]
Collar, Alonso [1 ]
Hatsukami, Thomas S. [1 ]
Yuan, Chun [1 ]
机构
[1] Univ Washington, Dept Radiol, Seattle, WA 98109 USA
关键词
MAGNETIC-FIELD STRENGTHS; IN-VIVO; ATHEROSCLEROTIC LESIONS; CEREBRAL-ISCHEMIA; INVERSION-RECOVERY; PLAQUE HEMORRHAGE; CLASSIFICATION; ASSOCIATION; STENOSIS; EVENTS;
D O I
10.1148/radiol.09090535
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the diagnostic performances of three T1-weighted 3.0-T magnetic resonance (MR) sequences at carotid intraplaque hemorrhage (IPH) imaging, with histologic analysis as the reference standard. Materials and Methods: Institutional review board approval and informed consent were obtained for this HIPAA-compliant study. Twenty patients scheduled for carotid endarterectomy underwent 3.0-T carotid MR imaging, including two-dimensional fast spin-echo, three-dimensional time-of-flight (TOF), and three-dimensional magnetization-prepared rapid acquisition gradient-echo (RAGE) sequences. Two reviewers blinded to the histologic findings assessed the presence, area, and signal intensity of IPH with each sequence. Detection statistics (sensitivity, specificity, and Cohen kappa values) and agreement between area measurements (Pearson correlation coefficient [r] values) were calculated for each sequence. Results: When all 231 available MR sections were included for analysis, the magnetization-prepared RAGE (kappa = 0.53) and fast spin-echo (kappa = 0.42) sequences yielded moderate agreement between MR and histologic measurements, while the TOF sequence yielded fair agreement (kappa = 0.33). However, when 47 sections with either small IPHs or heavily calcified IPHs were excluded, sensitivity, specificity, and k values, respectively, were 80%, 97%, and 0.80 for magnetization-prepared RAGE imaging; 70%, 92%, and 0.63 for fast spinecho imaging; and 56%, 96%, and 0.57 for TOF imaging. MR imaging-histologic analysis correlation for IPH area was highest with magnetization-prepared RAGE imaging (r = 0.813), followed by TOF (r = 0.745) and fast spin-echo (r = 0.497) imaging. The capability of these three sequences for IPH detection appeared to be in good agreement with the quantitative contrast of IPH versus background plaque tissue. Conclusion: The magnetization-prepared RAGE sequence, as compared with the fast spin-echo and TOF sequences, demonstrated higher diagnostic capability for the detection and quantification of IPH. Potential limitations of 3.0-T IPH MR imaging are related to hemorrhage size and coexisting calcification. (C) RSNA, 2010
引用
收藏
页码:551 / 563
页数:13
相关论文
共 34 条
[1]   Intraplaque hemorrhage assessed by high-resolution magnetic resonance imaging and C-reactive protein in carotid atherosclerosis [J].
Albuquerque, Luciano Cabral ;
Narvaes, Luciane Barreneche ;
Maciel, Aluisio Antunes ;
Staub, Henrique ;
Friedrich, Mauricio ;
Hoefel, Joao Rubiao Filho ;
Marques, Mauricio Barreira ;
Rohde, Luis Eduardo .
JOURNAL OF VASCULAR SURGERY, 2007, 46 (06) :1130-1137
[2]   Detection of intraplaque hemorrhage by magnetic resonance imaging in symptomatic patients with mild to moderate carotid stenosis predicts recurrent neurological events [J].
Altaf, Nishath ;
Daniels, Lucy ;
Morgan, Paul S. ;
Auer, Dorothee ;
MacSweeney, Shane T. ;
Moody, Alan R. ;
Gladman, John R. .
JOURNAL OF VASCULAR SURGERY, 2008, 47 (02) :337-342
[3]   Carotid intraplaque hemorrhage detected by magnetic resonance imaging predicts embolization during carotid endarterectomy [J].
Altaf, Nishath ;
Beech, Andrew ;
Goode, Stephen D. ;
Gladman, John R. ;
Moody, Alan R. ;
Auer, Dorothee P. ;
MacSweeney, Shane T. .
JOURNAL OF VASCULAR SURGERY, 2007, 46 (01) :31-36
[4]   Carotid intraplaque hemorrhage predicts recurrent symptoms in patients with high-grade carotid stenosis [J].
Altaf, Nishath ;
MacSweeney, Shane T. ;
Gladman, John ;
Auer, Dorothee P. .
STROKE, 2007, 38 (05) :1633-1635
[5]  
[Anonymous], 1993, An introduction to the bootstrap
[6]   In vivo 3D high-spatial-resolution MR imaging of intraplaque hemorrhage [J].
Bitar, Richard ;
Moody, Alan R. ;
Leung, General ;
Symons, Sean ;
Crisp, Susan ;
Butany, Jagdish ;
Rowsell, Corwyn ;
Kiss, Alexander ;
Nelson, Andrew ;
Maggisano, Robert .
RADIOLOGY, 2008, 249 (01) :259-267
[7]   Classification of human carotid atherosclerotic lesions with in vivo multicontrast magnetic resonance imaging [J].
Cai, JM ;
Hastukami, TS ;
Ferguson, MS ;
Small, R ;
Polissar, NL ;
Yuan, C .
CIRCULATION, 2002, 106 (11) :1368-1373
[8]   In vivo detection of hemorrhage in human atherosclerotic plaques with magnetic resonance imaging [J].
Cappendijk, VC ;
Cleutjens, KBJM ;
Heeneman, S ;
Schurink, GWH ;
Welten, RJTJ ;
Kessels, AGH ;
van Suylen, RJ ;
Daemen, MJAP ;
van Engelshoven, JMA ;
Kooi, ME .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (01) :105-110
[9]   Hemorrhage in the atherosclerotic carotid plaque: A high-resolution MRI study [J].
Chu, BC ;
Kampschulte, A ;
Ferguson, MS ;
Kerwin, WS ;
Yarnykh, VL ;
O'Brien, KD ;
Polissar, NL ;
Hatsukami, TS ;
Yuan, C .
STROKE, 2004, 35 (05) :1079-1084
[10]   Signal-to-noise measurements in magnitude images from NMR phased arrays [J].
Constantinides, CD ;
Atalar, E ;
McVeigh, ER .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (05) :852-857