The laboratory calibration of the SOHO Coronal Diagnostic Spectrometer

被引:17
作者
Lang, J [1 ]
Kent, BJ
Breeveld, AA
Breeveld, ER
Bromage, BJI
Hollandt, J
Payne, J
Pike, CD
Thompson, WT
机构
[1] Rutherford Appleton Lab, Didcot OX11 0QX, Oxon, England
[2] UCL, Mullard Space Sci Lab, Holmbury St Mary RH5 6NT, England
[3] Univ Cent Lancashire, Preston PR1 2HE, Lancs, England
[4] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
[5] SM&A Corp, Largo, MD 20774 USA
来源
JOURNAL OF OPTICS A-PURE AND APPLIED OPTICS | 2000年 / 2卷 / 02期
关键词
solar spectroscopy; extreme UV spectroscopy; radiometry; SOHO;
D O I
10.1088/1464-4258/2/2/305
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The laboratory end-to-end testing of the Coronal Diagnostic Spectrometer (CDS) experiment on the ESA/NASA SOHO mission is reported. A brief overview of CDS, which operates in the extreme-ultraviolet wavelength range, is given. Pertinent details of the calibration source are presented, followed by an account of the source beam characterization. A section is devoted to the determination of the instrument apertures and this includes an outline of the measurements, the results from both the grazing incidence and normal incidence aperture scans and their interpretation to yield estimated aperture areas. Next the measurement of spectrometer bandwidths and their comparison with expected values are described. Then the pre-launch wavelength calibrations are obtained. The section on sensitivity starts with an evaluation of the effects of polarization on the measurements. The expected sensitivities are then derived. The measurements, their analysis and a comparison of measured and expected sensitivities are presented for both the normal incidence and grazing incidence spectrometers. The application of the laboratory calibration to in-flight solar data is discussed.
引用
收藏
页码:88 / 106
页数:19
相关论文
共 26 条
[1]   A SPAN MCP DETECTOR FOR THE SOHO CORONAL DIAGNOSTIC SPECTROMETER [J].
BREEVELD, AA ;
EDGAR, ML ;
SMITH, A ;
LAPINGTON, JS ;
THOMAS, PD .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) :673-676
[2]  
BREEVELD AA, 1995, THESIS U LONDON
[3]  
Brooks DH, 1999, ASTRON ASTROPHYS, V347, P277
[4]  
BROWNING R, 1997, COMMUNICATION
[5]   HIGH-CURRENT HOLLOW-CATHODE AS A RADIOMETRIC TRANSFER STANDARD SOURCE FOR THE EXTREME VACUUM ULTRAVIOLET [J].
DANZMANN, K ;
GUNTHER, M ;
FISCHER, J ;
KOCK, M ;
KUHNE, M .
APPLIED OPTICS, 1988, 27 (23) :4947-4951
[6]   XUV ELECTRON-DENSITY DIAGNOSTICS FOR SOLAR-FLARES [J].
DERE, KP ;
MASON, HE ;
WIDING, KG ;
BHATIA, AK .
ASTROPHYSICAL JOURNAL SUPPLEMENT SERIES, 1979, 40 (02) :341-&
[7]   EXTREME ULTRAVIOLET-SPECTRA OF SOLAR ACTIVE REGIONS AND THEIR ANALYSIS [J].
DERE, KP .
SOLAR PHYSICS, 1982, 77 (1-2) :77-93
[8]   The SOHO mission: An overview [J].
Domingo, V ;
Fleck, B ;
Poland, AI .
SOLAR PHYSICS, 1995, 162 (1-2) :1-37
[9]   EXTREME-ULTRAVIOLET SPECTRUM OF A SOLAR ACTIVE REGION [J].
DUPREE, AK ;
HUBER, MCE ;
NOYES, RW ;
PARKINSON, WH ;
REEVES, EM ;
WITHBROE, GL .
ASTROPHYSICAL JOURNAL, 1973, 182 (01) :321-333
[10]   EXTREME-ULTRAVIOLET SPECTRUM OF QUIET SUN [J].
DUPREE, AK ;
REEVES, EM .
ASTROPHYSICAL JOURNAL, 1971, 165 (03) :599-&