Novel pre-oxidizing cell for elimination of electroactive interferents during biosensor analysis. Application to glucose determination in real samples

被引:7
作者
Gavalas, VG [1 ]
Fouskaki, MG [1 ]
Chaniotakis, NA [1 ]
机构
[1] Univ Crete, Dept Chem, Analyt Chem Lab, Iraklion 71409, Crete, Greece
关键词
pre-oxidizing cell; interferents; amperometric biosensor; real-analysis;
D O I
10.1080/00032710008543197
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The application of a pre-oxidizing cell for the on-line elimination of electrooxidizable interferents in a flow-system equipped with an amperometric biosensor is presented. The reactor cell is based on vitreous carbon foam with large surface areas for the fast oxidation of electroactive compounds. The efficiency of the cell is evaluated using the most significant interferences found in real samples, those of ascorbic acid uric acid and acetaminophen. The application of the cell, in the online analysis of glucose in real samples is finally demonstrated. The results are in agreement with those obtained by chromatography measurements (correlation coefficient: 1.04+/-0.02).
引用
收藏
页码:2391 / 2405
页数:15
相关论文
共 31 条
[1]   Layer-by-layer construction of enzyme multilayers on an electrode for the preparation of glucose and lactate sensors: Elimination of ascorbate interference by means of an ascorbate oxidase multilayer [J].
Anzai, J ;
Takeshita, H ;
Kobayashi, Y ;
Osa, T ;
Hoshi, T .
ANALYTICAL CHEMISTRY, 1998, 70 (04) :811-817
[2]   ONLINE MEASUREMENT OF BRAIN GLUTAMATE WITH AN ENZYME/POLYMER-COATED TUBULAR ELECTRODE [J].
BERNERS, MOM ;
BOUTELLE, MG ;
FILLENZ, M .
ANALYTICAL CHEMISTRY, 1994, 66 (13) :2017-2021
[3]  
BETTERIDGE D, 1978, ANAL CHEM, V50, P831
[4]  
Celej MS, 1998, ELECTROANAL, V10, P771, DOI 10.1002/(SICI)1521-4109(199809)10:11<771::AID-ELAN771>3.0.CO
[5]  
2-P
[6]   Electrochemical immobilisation of enzymes on conducting organic salt electrodes: characterisation of an oxygen independent and interference-free glucose biosensor [J].
Centonze, D ;
Losito, I ;
Malitesta, C ;
Palmisano, F ;
Zambonin, PG .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1997, 435 (1-2) :103-111
[7]  
FOUSKAKI MG, 1999, P INSTRUMENTAL METHO, V11, P604
[8]  
Gajovic N, 1999, ELECTROANAL, V11, P1377, DOI 10.1002/(SICI)1521-4109(199912)11:18<1377::AID-ELAN1377>3.0.CO
[9]  
2-B
[10]   Amperometric glucose biosensor based on glucose oxidase immobilized in poly(o-phenylenediamine) layer [J].
Garjonyte, R ;
Malinauskas, A .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 56 (1-2) :85-92