A comparison of particle mass spectrometers during the 1999 Atlanta Supersite Project

被引:84
作者
Middlebrook, AM
Murphy, DM
Lee, SH
Thomson, DS
Prather, KA
Wenzel, RJ
Liu, DY
Phares, DJ
Rhoads, KP
Wexler, AS
Johnston, MV
Jimenez, JL
Jayne, JT
Worsnop, DR
Yourshaw, I
Seinfeld, JH
Flagan, RC
机构
[1] NOAA, Aeron Lab, Boulder, CO 80305 USA
[2] Univ Colorado, Dept Chem & Biochem, Cooperat Inst Res Environm Sci, Boulder, CO 80309 USA
[3] Univ Calif Riverside, Dept Chem, Riverside, CA 92521 USA
[4] Univ Delaware, Dept Mech Engn, Newark, DE 19716 USA
[5] Univ Delaware, Dept Chem & Biochem, Newark, DE 19716 USA
[6] Aerodyne Res Inc, Billerica, MA 01821 USA
[7] CALTECH, Dept Environm Engn Sci, Pasadena, CA 91125 USA
[8] CALTECH, Dept Chem Engn, Pasadena, CA 91125 USA
关键词
aerosol; mass spectrometer; single particle composition;
D O I
10.1029/2001JD000660
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
[1] During the Atlanta Supersite Project, four particle mass spectrometers were operated together for the first time: NOAA's Particle Analysis by Laser Mass Spectrometer ( PALMS), University of California at Riverside's Aerosol Time-of-Flight Mass Spectrometer (ATOFMS), University of Delaware's Rapid Single-Particle Mass Spectrometer II (RSMS-II), and Aerodyne's Aerosol Mass Spectrometer (AMS). Although these mass spectrometers are generally classified as similar instruments, they clearly have different characteristics due to their unique designs. One primary difference is related to the volatilization/ionization method: PALMS, ATOFMS, and RSMS-II utilize laser desorption/ ionization, whereas particles in the AMS instrument are volatilized by impaction onto a heated surface with the resulting components ionized by electron impact. Thus mass spectral data from the AMS are representative of the ensemble of particles sampled, and those from the laser-based instruments are representative of individual particles. In addition, the AMS instrument cannot analyze refractory material such as soot, sodium chloride, and crustal elements, and some sulfate or water-rich particles may not always be analyzed with every laser-based instrument. A main difference among the laser-based mass spectrometers is that the RSMS-II instrument can obtain size-resolved single particle composition information for particles with aerodynamic diameters as small as 15 nm. The minimum sizes analyzed by ATOFMS and PALMS are 0.2 and about 0.35 mm, respectively, in aerodynamic diameter. Furthermore, PALMS, ATOFMS, and RSMS-II use different laser ionization conditions. Despite these differences the laser-based instruments found similar individual particle classifications, and their relative fractions among comparable sized particles from Atlanta were broadly consistent. Finally, the AMS measurements of the nitrate/sulfate mole ratio were highly correlated with composite measurements (r(2) = 0.93). In contrast, the PALMS nitrate/sulfate ion ratios were only moderately correlated (r(2) similar to 0.7).
引用
收藏
页数:13
相关论文
共 38 条
  • [1] Particle detection efficiencies of aerosol time of flight mass spectrometers under ambient sampling conditions
    Allen, JO
    Fergenson, DP
    Gard, EE
    Hughes, LS
    Morrical, BD
    Kleeman, MJ
    Gross, DS
    Gälli, ME
    Prather, KA
    Cass, GR
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (01) : 211 - 217
  • [2] A field-based approach for determining ATOFMS instrument sensitivities to ammonium and nitrate
    Bhave, PV
    Allen, JO
    Morrical, BD
    Fergenson, DP
    Cass, GR
    Prather, KA
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2002, 36 (22) : 4868 - 4879
  • [3] Source apportionment of fine particulate matter by clustering single-particle data: Tests of receptor model accuracy
    Bhave, PV
    Fergenson, DP
    Prather, KA
    Cass, GR
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2001, 35 (10) : 2060 - 2072
  • [4] Two-color laser induced evaporation dynamics of liquid aerosols probed by time-of-flight mass spectrometry
    Cabalo, J
    Zelenyuk, A
    Baer, T
    Miller, RE
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 2000, 33 (1-2) : 3 - 19
  • [5] Real-time monitoring of the surface and total composition of aerosol particles
    Carson, PG
    Johnston, MV
    Wexler, AS
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 1997, 26 (04) : 291 - 300
  • [6] Ablation, flux, and atmospheric implications of meteors inferred from stratospheric aerosol
    Cziczo, DJ
    Thomson, DS
    Murphy, DM
    [J]. SCIENCE, 2001, 291 (5509) : 1772 - 1775
  • [7] Quantification of ATOFMS data by multivariate methods
    Fergenson, DP
    Song, XH
    Ramadan, Z
    Allen, JO
    Hughes, LS
    Cass, GR
    Hopke, PK
    Prather, KA
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (15) : 3535 - 3541
  • [8] Real-time analysis of individual atmospheric aerosol particles: Design and performance of a portable ATOFMS
    Gard, E
    Mayer, JE
    Morrical, BD
    Dienes, T
    Fergenson, DP
    Prather, KA
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (20) : 4083 - 4091
  • [9] Direct observation of heterogeneous chemistry in the atmosphere
    Gard, EE
    Kleeman, MJ
    Gross, DS
    Hughes, LS
    Allen, JO
    Morrical, BD
    Fergenson, DP
    Dienes, T
    Gälli, ME
    Johnson, RJ
    Cass, GR
    Prather, KA
    [J]. SCIENCE, 1998, 279 (5354) : 1184 - 1187
  • [10] Laser desorption/ionization of single ultrafine multicomponent aerosols
    Ge, ZZ
    Wexler, AS
    Johnston, MV
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1998, 32 (20) : 3218 - 3223