Statistical evaluation of hearing screening by distortion product otoacoustic emissions

被引:8
作者
Bonfils, P
Avan, P
Landais, P
Erminy, M
Biacabe, B
机构
[1] ENT Dept, Auditory Res Lab, CNRS UMR Neurobiol Syst Sensorimoteurs, F-75015 Paris, France
[2] Hosp Boucicaut, Format Associee Claude Bernard, Paris, France
[3] Univ Paris 05, Dept Biostat, Necker Hosp, Fac Necker Enfants Malad, Paris, France
[4] Univ Auvergne, Fac Med, Biophys Lab, Clermont Ferrand, France
关键词
audition; cochlea; distortion product otoacoustic emission; hearing screening;
D O I
10.1177/000348949710601209
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
The aim of this study was to provide a statistical evaluation of the screening properties of distortion product otoacoustic emissions (DPOEs) in individuals with clinically normal hearing and in patients with pure sensorineural deafness of various degrees. The main informational parameters used were sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and the analysis of receiver operating characteristic (ROC) curves, For each frequency tested, ears were classified as a function of their audiometric threshold. Two groups were defined relative to an arbitrary reference, the "audiometric criterion." The PPV decreased and NPV increased with increases in the audiometric criterion. Each point of the ROC curve represents the relationship between the false alarm rate and the hit rate for each audiometric criterion ranging between 10 and 75 dB hearing level: the lower the audiometric criterion, the fewer the hit rate value, and the lower the false alarm value. The audiometric criterion giving the highest hit rate and the lowest false alarm rate was 55 to 60 dB hearing level for primaries at 60 and 70 dB sound pressure level, or 25 to 30 dB hearing level for primaries at 30, 40, and 50 dB sound pressure level, These two different behaviors of ROC curves are consistent with the hypothesis that DPOEs do not represent activity at a single location along the basilar membrane.
引用
收藏
页码:1052 / 1062
页数:11
相关论文
共 35 条
[1]   USING ACOUSTIC DISTORTION PRODUCTS TO MEASURE THE COCHLEAR AMPLIFIER GAIN ON THE BASILAR-MEMBRANE [J].
ALLEN, JB ;
FAHEY, PF .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1992, 92 (01) :178-188
[2]  
AVAN P, 1993, AUDIOLOGY, V32, P12
[3]   DISTORTION-PRODUCT OTOACOUSTIC EMISSIONS IN NEONATES - NORMATIVE DATA [J].
BONFILS, P ;
AVAN, P ;
FRANCOIS, M ;
TROTOUX, J ;
NARCY, P .
ACTA OTO-LARYNGOLOGICA, 1992, 112 (05) :739-744
[4]   CLINICAL-SIGNIFICANCE OF OTOACOUSTIC EMISSIONS - A PERSPECTIVE [J].
BONFILS, P ;
AVAN, P ;
FRANCOIS, M ;
MARIE, P ;
TROTOUX, J ;
NARCY, P .
EAR AND HEARING, 1990, 11 (02) :155-158
[5]  
BONFILS P, 1992, ARCH OTOLARYNGOL, V118, P1069
[6]   AUDITORY THRESHOLD EVALUATION BY DISTORTION-PRODUCT OTOACOUSTIC EMISSIONS USING DECISION-SUPPORT SYSTEM [J].
BONFILS, P ;
AVAN, P ;
ELBEZ, M ;
DEYS, S ;
ERMINY, M ;
FRANCOIS, M .
ACTA OTO-LARYNGOLOGICA, 1994, 114 (04) :360-365
[7]   ACOUSTIC DISTORTION PRODUCTS CAN BE USED TO MONITOR THE EFFECTS OF CHRONIC GENTAMICIN TREATMENT [J].
BROWN, AM ;
MCDOWELL, B ;
FORGE, A .
HEARING RESEARCH, 1989, 42 (2-3) :143-156
[9]   PROPERTIES OF AUDITORY-NERVE RESPONSES IN ABSENCE OF OUTER HAIR CELLS [J].
DALLOS, P ;
HARRIS, D .
JOURNAL OF NEUROPHYSIOLOGY, 1978, 41 (02) :365-383
[10]   NONLINEAR PHENOMENA AS OBSERVED IN THE EAR CANAL AND AT THE AUDITORY-NERVE [J].
FAHEY, PF ;
ALLEN, JB .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1985, 77 (02) :599-612