Total knee arthroplasty for severe valgus deformity - Five to fourteen-year follow-up

被引:99
作者
Elkus, M [1 ]
Ranawat, CS [1 ]
Rasquinha, VJ [1 ]
Babhulkar, S [1 ]
Rossi, R [1 ]
Ranawat, AS [1 ]
机构
[1] Lenox Hill Hosp, Dept Orthoped Surg, New York, NY 10021 USA
关键词
D O I
10.2106/00004623-200412000-00013
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: In 1985, the senior author (C.S.R.) developed a new soft-tissue release technique to balance valgus knees to avoid unacceptably high rates of late-onset instability and the need for primary constrained implants. This report describes the soft-tissue release technique and its long-term results when performed in primary total knee arthroplasty in patients with a severe valgus knee deformity. Methods: Four hundred and ninety consecutive total knee arthroplasties were performed by one surgeon between January 1988 and December 1992. In this group, seventy-one patients (eighty-five knees) had a vagus deformity of >10degrees. Thirty-two patients (thirty-six knees) died, and four patients (seven knees) were lost to follow-up, leaving thirtyfive patients (forty-two knees) followed for a minimum of five years. These twenty-seven women and eight men had a mean age of sixty-seven years at the time of the index operation. The technique included an inside-out soft-tissue release of the posterolateral aspect of the capsule with pie-crusting of the iliotibial band and resection of the proximal part of the tibia and distal part of the femur to provide a balanced, rectangular space. Cemented, posterior stabilized implants were used in all knees. Clinical and radiographic evaluations were performed at one, five, and ten years postoperatively. Results: The mean modified Knee Society clinical score improved from 30 points preoperatively to 93 points postoperatively, and the mean functional score improved from 34 to 81 points. The mean range of motion was 110degrees both preoperatively and postoperatively. The mean coronal alignment was corrected from 150 of valgus preoperatively to 50 of vagus postoperatively. Three patients underwent revision surgery because of delayed infection, premature polyethylene wear, and patellar loosening in one patient each. There were no cases of delayed instability. Conclusions: The inside-out release technique to correct a fixed vagus deformity in patients undergoing primary total knee arthroplasty is reproducible and provides excellent long-term results. Level of Evidence: Therapeutic study, Level IV (case series [no, or historical, control group]). See Instructions to Authors for a complete description of levels of evidence.
引用
收藏
页码:2671 / 2676
页数:6
相关论文
共 17 条
[1]  
Aglietti P, 1996, Am J Knee Surg, V9, P8
[2]  
BUECHEL FF, 1990, CLIN ORTHOP RELAT R, P170
[3]  
Easley ME, 2000, CLIN ORTHOP RELAT R, P58
[4]  
EWALD FC, 1989, CLIN ORTHOP RELAT R, P9
[5]  
Favorito Paul J, 2002, J Am Acad Orthop Surg, V10, P16
[6]   Replacement arthroplasty of the valgus knee - A modified lateral capsular approach with repositioning of vastus lateralis [J].
Fiddian, NJ ;
Blakeway, C ;
Kumar, A .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (05) :859-861
[7]  
Healy WL, 1998, CLIN ORTHOP RELAT R, P161
[8]   TOTAL CONDYLAR KNEE PROSTHESIS - REPORT OF 220 CASES [J].
INSALL, J ;
SCOTT, WN ;
RANAWAT, CS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1979, 61 (02) :173-180
[9]   SEVERE VARUS AND VALGUS DEFORMITIES TREATED BY TOTAL KNEE ARTHROPLASTY [J].
KARACHALIOS, T ;
SARANGI, PP ;
NEWMAN, JH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (06) :938-942
[10]  
KEBLISH PA, 1991, CLIN ORTHOP RELAT R, P52