Direct-injection LC-MS-MS method for high-throughput simultaneous quantitation of simvastatin and simvastatin acid in human plasma

被引:85
作者
Jemal, M [1 ]
Ouyang, Z [1 ]
Powell, ML [1 ]
机构
[1] Bristol Myers Squibb Co, Pharmaceut Res Inst, Bioanalyt Res Metab & Pharmacokinet, New Brunswick, NJ 08903 USA
关键词
liquid chromatography; mass spectrometry-mass spectrometry method; simvastatin; simvastatin acid; human plasma;
D O I
10.1016/S0731-7085(00)00309-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A direct-injection liquid chromatography -mass spectrometry--mass spectrometry (LC-RIS-MS) method was developed and validated for the simultaneous quantitation in human plasma of the widely used cholesterol-lowering prodrug simvastatin and its in vivo generated active drug, simvastatin acid. The plasma samples were injected into the LC-MS-MS system after simply adding the internal standard solution in an aqueous buffer and centrifuging. The analytes in the buffered plasma samples were found to be stable For at least 24 h at 4 degrees C. The method was successfully validated under the challenging condition of using a large number of quality control (QC) samples including those in which the ratio of the simvastatin concentration to the simvastatin acid concentration was different from the concentration ratio in the calibration curve standards. Under the dual stabilizing conditions of lower temperature (4 degrees C) and lower plasma pl-l of 4.9, the in-process hydrolysis of simvastatin to simvastatin acid or the lactonization of simvastatin acid to simvastatin was minimized to less than or equal to 1.0%. Although the entire run time for on-line cleanup and analysis was only 2.5 min, chromatographic base-line separation of simvastatin from simvastatin acid, which was required to avoid the interference by simvastatin acid with the simvastatin selected reaction monitoring channel, was achieved. The desired lower limit of quantitation of 0.5 ng/ml was achieved by injecting only an equivalent of 8.0 mu l of the plasma sample. The extraction column lasted for at least 500 injections. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:323 / 340
页数:18
相关论文
共 19 条
[1]  
BOLOGNA M, 1994, INT J IMMUNOPATH PH, V7, P79
[2]   SIMULTANEOUS DETERMINATION OF SIMVASTATIN AND ITS HYDROXY ACID FORM IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH UV DETECTION [J].
CARLUCCI, G ;
MAZZEO, P ;
BIORDI, L ;
BOLOGNA, M .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1992, 10 (09) :693-697
[3]   Clinical pharmacokinetics of 3-hydroxy-3-methylglutaryl-coenzyme A reductase inhibitors [J].
Desager, JP ;
Horsmans, Y .
CLINICAL PHARMACOKINETICS, 1996, 31 (05) :348-371
[4]  
GILBERT JD, 1994, METHODOL SURV BIOANA, V23, P157
[5]  
Jemal M, 1998, RAPID COMMUN MASS SP, V12, P1389, DOI 10.1002/(SICI)1097-0231(19981015)12:19<1389::AID-RCM329>3.3.CO
[6]  
2-K
[7]  
Jemal M, 1999, RAPID COMMUN MASS SP, V13, P97, DOI 10.1002/(SICI)1097-0231(19990130)13:2<97::AID-RCM461>3.0.CO
[8]  
2-T
[9]  
Jemal M, 1999, RAPID COMMUN MASS SP, V13, P1462, DOI 10.1002/(SICI)1097-0231(19990730)13:14<1462::AID-RCM668>3.3.CO
[10]  
2-Q