Contrast-enhanced peripheral MR angiography at 3.0 Tesla: initial experience with a whole-body scanner in healthy volunteers

被引:44
作者
Leiner, T
de Vries, M
Hoogeveen, R
Vasbinder, GBC
Lemaire, E
van Engelshoven, JMA
机构
[1] Maastricht Univ Hosp, Dept Radiol, Cardiovasc Res Inst Maastricht, Maastricht, Netherlands
[2] Philips Med Syst, Dept Clin Sci, Best, Netherlands
关键词
high field strength MRI; contrast-enhanced MR angiography; comparative studies; peripheral arteries; peripheral arterial disease;
D O I
10.1002/jmri.10297
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To report preliminary experience with contrast-enhanced magnetic resonance angiography (CE-MRA) of the peripheral arteries on a 3.0 T whole-body scanner equipped with a prototype body coil. Materials and Methods: Four healthy volunteers were imaged on the 3.0 T system and, for comparative purposes, two of the subjects were also imaged on a commercially available 1.5 T whole-body system. To investigate field strength influence on objective image quality, signal-to-noise (SN) and contrast-to-noise (CN) ratios were calculated for named vessels from the infrarenal aorta to the ankles at both field strengths. Comparable imaging protocols were used at both field strengths. In addition, two reviewers, blinded for field strength, gave subjective image quality scores (three-point scale). Results: SN and CN ratios were approximately equal on both systems (variation less than or equal to9%) for the iliac and proximal upper leg stations. For the popliteal and lower leg stations SN ratios were 36% and 97% higher, and CN ratios were 44% and 127% higher, at 3.0 T. Subjective image quality at 3.0 T was substantially better for the distal upper and lower legs. Conclusion: Contrast-enhanced peripheral MRA is possible at 3.0 T when an imaging protocol similar to a current state-of-the-art 1.5 T protocol is used. Objective and subjective image quality at 3.0 T is comparable for the iliac and upper legs but better for the popliteal and lower leg arteries.
引用
收藏
页码:609 / 614
页数:6
相关论文
共 16 条
[1]   RF MAGNETIC-FIELD PENETRATION, PHASE-SHIFT AND POWER DISSIPATION IN BIOLOGICAL TISSUE - IMPLICATIONS FOR NMR IMAGING [J].
BOTTOMLEY, PA ;
ANDREW, ER .
PHYSICS IN MEDICINE AND BIOLOGY, 1978, 23 (04) :630-643
[2]  
Campbell BA, 2000, PROGRESS INFANCY RES, V1, P1
[3]   Calculations of B1 distribution, SNR, and SAR for a surface coil adjacent to an anatomically-accurate human body model [J].
Collins, CM ;
Smith, MB .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) :692-699
[4]  
Goyen M, 2001, Top Magn Reson Imaging, V12, P327, DOI 10.1097/00002142-200110000-00003
[5]   Peripheral MR angiography [J].
Ho, KYJAM ;
Leiner, T ;
de Haan, MW ;
van Engelshoven, JMA .
EUROPEAN RADIOLOGY, 1999, 9 (09) :1765-1774
[6]   INTRAVASCULAR SUSCEPTIBILITY CONTRAST MECHANISMS IN TISSUES [J].
KENNAN, RP ;
ZHONG, JH ;
GORE, JC .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (01) :9-21
[7]   Magnetic resonance angiography for the evaluation of lower extremity arterial disease - A meta-analysis [J].
Koelemay, MJW ;
Lijmer, JG ;
Stoker, J ;
Legemate, DA ;
Bossuyt, RMM .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2001, 285 (10) :1338-1345
[8]   Peripheral arterial disease: Meta-analysis of the diagnostic performance of MR angiography [J].
Nelemans, PJ ;
Leiner, T ;
de Vet, HCW ;
van Engelshoven, JMA .
RADIOLOGY, 2000, 217 (01) :105-114
[9]  
PARKER DL, 1993, MAGNETIC RESONANCE A, P56
[10]  
Pruessmann KP, 1999, MAGNET RESON MED, V42, P952, DOI 10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO