Ultrasonically targeted delivery into endothelial and smooth muscle cells in ex vivo arteries

被引:53
作者
Hallow, Daniel M. [1 ]
Mahajan, Anui D. [1 ]
Prausnitz, Mark R. [1 ]
机构
[1] Georgia Inst Technol, Sch Chem & Biomol Engn, Atlanta, GA 30332 USA
关键词
ultrasound; cavitation; intracellular drug delivery; endothelial cells; targeted drug delivery;
D O I
10.1016/j.jconrel.2006.12.029
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This study tested the hypothesis that ultrasound can target intracellular uptake of drugs into vascular endothelial cells (ECs) at low to intermediate energy and into smooth muscle cells (SMCs) at high energy. Ultrasound-enhanced delivery has been shown to enhance and target intracellular drug and gene delivery in the vasculature to treat cardiovascular disease, but quantitative studies of the delivery process are lacking. Viable ex vivo porcine carotid arteries were placed in a solution containing a model drug, TO-PRO (R)-1, and Optison (R) microbubbles. Arteries were exposed to ultrasound at 1.1 MHz and acoustic energies of 5.0, 66, or 630 J/cm(2). Using confocal microscopy and fluorescent labeling of cells, the artery endothelium and media were imaged to determine the localization and to quantify intracellular uptake and cell death. At low to intermediate ultrasound energy, ultrasound was shown to target intracellular delivery into viable cells that represented 9-24% of exposed ECs. These conditions also typically caused 7-25% EC death. At high energy, intracellular delivery was targeted to SMCs, which was associated with denuding or death of proximal ECs. This work represents the first known in-depth study to evaluate intracellular uptake into cells in tissue. We conclude that significant intracellular uptake of molecules can be targeted into ECs and SMCs by ultrasound-enhanced delivery suggesting possible applications for treatment of cardiovascular diseases and dysfunctions. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:285 / 293
页数:9
相关论文
共 40 条
[1]  
*AC SOC AM, 2002, BUBBL DET CAV MON
[2]   High-efficiency endovascular gene delivery via therapeutic ultrasound [J].
Amabile, PG ;
Waugh, JM ;
Lewis, TN ;
Elkins, CJ ;
Janas, W ;
Dake, MD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (07) :1975-1980
[3]   Cell-selective viral gene delivery vectors for the vasculature [J].
Baker, AH ;
Kritz, A ;
Work, LM ;
Nicklin, SA ;
Nicklin, A .
EXPERIMENTAL PHYSIOLOGY, 2005, 90 (01) :27-31
[4]   Use of ultrasound contrast agents for gene or drug delivery in cardiovascular medicine [J].
Bekeredjian, R ;
Grayburn, PA ;
Shohet, RV .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (03) :329-335
[5]   Erosion of artificial endothelia in vitro by pulsed ultrasound:: Acoustic pressure, frequency, membrane orientation and microbubble contrast agent dependence [J].
Brayman, AA ;
Lizotte, LM ;
Miller, MW .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1999, 25 (08) :1305-1320
[6]  
CHESLER NC, 1998, J VASC INVEST, V4, P123
[7]  
Cines DB, 1998, BLOOD, V91, P3527
[8]  
Cooke JP, 2000, VASC MED, V5, P49, DOI 10.1177/1358836X0000500108
[9]   Ultrasound contrast agents:: properties, principles of action, tolerance, and artifacts [J].
Correas, JM ;
Bridal, L ;
Lesavre, A ;
Méjean, A ;
Claudon, M ;
Hélénon, O .
EUROPEAN RADIOLOGY, 2001, 11 (08) :1316-1328
[10]   The role of inflammation in vascular injury and repair [J].
Davis, C ;
Fischer, J ;
Ley, K ;
Sarembock, IJ .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2003, 1 (08) :1699-1709