Purpose: Because of the high incidence of nonconvulsive status epilepticus (NCSE), the attraction of a "quick and easy" screening electroencephalogram (EEG) is obvious. Previous studies have shown utility of hairline EEG in diagnosing epilepsy. However, this technique has not been evaluated as a screening tool for NCSE. We wanted to provide proof of principle that a screening hairline EEG has sufficient sensitivity to use as a screening tool for diagnosing NCSE. Methods: A total of 120, 2- to 3-min EEG samples of normal and various abnormal digital EEG studies were reformatted in three six-channel montages (A, longitudinal bipolar; B, referential to ipsilateral ear; C, referential to contralateral ear) that mimicked a hairline recording and were interpreted by five neurophysiologists. The test data interpretation was compared with the original EEG interpretation. Results: Performance was best with montages A and B; 71% and 70.5% of the samples were interpreted correctly by using these montages. Only 65% of the samples were correctly interpreted by using montage C. With the best montage (A), the sensitivities ranged from 91% for normal EEG to 54% for periodic lateralized epileptiform discharges (PLEDs). The sensitivity for seizures was only 72%. Seizures were frequently misinterpreted as more benign patterns such as normal and diffuse slowing. Conclusions: EEG data reformatted to resemble a hairline EEG had low sensitivity for detecting seizures. As a result, we do not recommend further pursuit of hairline EEG as a "quick and easy" screening tool for NCSE.
引用
收藏
页码:959 / 965
页数:7
相关论文
共 17 条
[1]   ESTIMATING THE IMPORTANCE OF EPILEPTIFORM ABNORMALITIES DISCOVERED ON CASSETTE ELECTROENCEPHALOGRAPHIC MONITORING [J].
BRIDGERS, SL ;
WADE, PB ;
EBERSOLE, JS .
ARCHIVES OF NEUROLOGY, 1989, 46 (10) :1077-1079
[2]   EEG OUTSIDE THE HAIRLINE - DETECTION OF EPILEPTIFORM ABNORMALITIES [J].
BRIDGERS, SL ;
EBERSOLE, JS .
NEUROLOGY, 1988, 38 (01) :146-149
[3]   CASSETTE ELECTROENCEPHALOGRAPHY IN THE EVALUATION OF NEONATAL SEIZURES [J].
BRIDGERS, SL ;
EBERSOLE, JS ;
MENT, LR ;
EHRENKRANZ, RA ;
SILVA, CG .
ARCHIVES OF NEUROLOGY, 1986, 43 (01) :49-51
[4]   EVALUATION OF AMBULATORY CASSETTE EEG MONITORING .3. DIAGNOSTIC-ACCURACY COMPARED TO INTENSIVE INPATIENT EEG MONITORING [J].
EBERSOLE, JS ;
LEROY, RF .
NEUROLOGY, 1983, 33 (07) :853-860
[5]   AN EVALUATION OF AMBULATORY, CASSETTE EEG MONITORING .2. DETECTION OF INTERICTAL ABNORMALITIES [J].
EBERSOLE, JS ;
LEROY, RF .
NEUROLOGY, 1983, 33 (01) :8-18
[6]   DIRECT COMPARISON OF 3-CHANNEL AND 8-CHANNEL AMBULATORY CASSETTE EEG WITH INTENSIVE INPATIENT MONITORING [J].
EBERSOLE, JS ;
BRIDGERS, SL .
NEUROLOGY, 1985, 35 (06) :846-854
[7]  
Hirsch Lawrence J, 2004, Am J Electroneurodiagnostic Technol, V44, P137
[8]   4-CHANNEL 24 HOUR CASSETTE RECORDER FOR LONG-TERM EEG MONITORING OF AMBULATORY PATIENTS [J].
IVES, JR ;
WOODS, JF .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1975, 39 (01) :88-92
[9]   Continuous EEG monitoring in the neuroscience intensive care unit and emergency department [J].
Jordan, KG .
JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 1999, 16 (01) :14-39
[10]   CONTINUOUS EEG AND EVOKED-POTENTIAL MONITORING IN THE NEUROSCIENCE INTENSIVE-CARE UNIT [J].
JORDAN, KG .
JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 1993, 10 (04) :445-475