Diagnostic monitoring of urine by means of synchronous fluorescence spectrum

被引:50
作者
Dubayová, K
Kusnír, J
Podracká, L
机构
[1] Safarik Univ, Fac Med, Dept Med Chem & Biochem, Kosice 04066, Slovakia
[2] Safarik Univ, Fac Med, Clin Children & Adolescent, Kosice 04066, Slovakia
来源
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS | 2003年 / 55卷 / 02期
关键词
synchronous fluorescence spectrum; urine;
D O I
10.1016/S0165-022X(03)00031-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel approach to clinical-biochemical analysis of urine is presented in this work. Urine composition is defined graphically as a record of synchronous fluorescence spectra (SFS). The graphical standard has been made from SFS of urine samples from healthy children. Simple comparison of a standard record with that of an analyzed urine sample will immediately reveal changes in its composition. Reproducibility of the graphical definition is very high and it maintains its characteristic shape during repeated measurements over a span of 2 years. It is possible to elaborate patients' own standard for those with chronic illness. It differs from a normal course but it is characteristic for a given patient and it enables the clinician to monitor changes or the outcome of therapy at regular medical examinations. Application of this method for monitoring of urine composition for selected cases is a new alternative with several advantages. Analysis without any added reagents very quickly detects some illnesses near onset when they may be clinically asymptomatic and classical screening methods show negative results. Computerization of spectral measuring and filing the results enables to give a likely diagnosis or a deviation from standard. This method can also serve a doctor-clinician either to confirm or to exclude a concrete diagnosis. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:111 / 119
页数:9
相关论文
共 14 条
[1]   Multicomponent analysis by off-line combination of synchronous fluorescence spectroscopy and capillary electrophoresis of collagen glycation adducts [J].
Deyl, Z ;
Miksík, I ;
Zicha, J .
JOURNAL OF CHROMATOGRAPHY A, 1999, 836 (01) :161-171
[2]  
DUBAYOVA K, 1998, FOLIA MED CASSOV, V55, P105
[3]  
DUBAYOVA K, 1997, FOLIA MED CASSOV, V54, P123
[4]   Quantitative multicomponent analysis of polycyclic aromatic hydrocarbons in water samples [J].
Guiteras, J ;
Beltrán, JL ;
Ferrer, R .
ANALYTICA CHIMICA ACTA, 1998, 361 (03) :233-240
[5]   THE TOTAL FLUORESCENCE OF HUMAN-URINE [J].
LEINER, MJP ;
HUBMANN, MR ;
WOLFBEIS, OS .
ANALYTICA CHIMICA ACTA, 1987, 198 :13-23
[6]   Application of artificial neural networks for the simultaneous determination of a mixture of fluorescent dyes by synchronous fluorescence [J].
Li, QF ;
Yao, XJ ;
Chen, XG ;
Liu, MC ;
Zhang, RS ;
Zhang, XY ;
Hu, ZD .
ANALYST, 2000, 125 (11) :2049-2053
[7]   Synchronous fluorescence spectrometric methodology in the wavelength domain [J].
Li, YQ ;
Huang, XZ ;
Xu, JG .
JOURNAL OF FLUORESCENCE, 1999, 9 (03) :173-179
[8]  
LLOYD JBF, 1982, J FORENSIC SCI, V27, P352
[9]   PARTLY QUENCHED, SYNCHRONOUSLY EXCITED FLUORESCENCE EMISSION-SPECTRA IN CHARACTERIZATION OF COMPLEX MIXTURES [J].
LLOYD, JBF .
ANALYST, 1974, 99 (1184) :729-738
[10]  
PHELAN V, 1994, INT LAB NEWS, V7, P12