Dosimetric improvements following 3D planning of tangential breast irradiation

被引:46
作者
Aref, A
Thornton, D
Youssef, E
He, T
Tekyi-Mensah, S
Denton, L
Ezzell, G
机构
[1] Wayne State Univ, Sch Med, Gershenson Radiat Oncol Ctr, Detroit, MI USA
[2] Barbara Ann Karmanos Canc Inst, Detroit, MI USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2000年 / 48卷 / 05期
关键词
breast cancer; radiation technique; compensator; 3D planning; breast dosimetry;
D O I
10.1016/S0360-3016(00)00808-7
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To evaluate the dosimetric difference between a simple radiation therapy plan utilizing a single contour and a more complex three-dimensional (3D) plan utilizing multiple contours, lung inhomogeneity correction, and dose-based compensators. Methods and Materials: This is a study of the radiation therapy (RT) plans of 85 patients with early breast cancer. All patients were considered for breast-conserving management and treated by conventional tangential fields technique. Two plans were generated for each patient. The first RT plan was based on a single contour taken at the central axis and utilized two wedges. The second RT plan was generated by using the 3D planning system to design dose based compensators after lung inhomogeneity correction had been made. The endpoints of the study were the comparison between the volumes receiving greater than 105% and greater than 110% of the reference dose, as well as the magnitude of the treated volume maximum dose. Dosimetric improvement was defined to be of significant value if the volume receiving > 105% of one plan was reduced by at least 50%,vith the absolute difference between the volumes being 5% or greater. The dosimetric improvements in 49 3D plans (58%) were considered of significant value. patients' field separation and breast size did not predict the magnitude of improvement in dosimetry. Conclusion: Dose-based compensator plans significantly reduced the volumes receiving > 105%, >110%, and volume maximum dose. (C) 2000 Elsevier Science Inc.
引用
收藏
页码:1569 / 1574
页数:6
相关论文
共 16 条
[1]  
Alecu R, 1999, Med Dosim, V24, P33, DOI 10.1016/S0958-3947(98)00044-2
[2]  
Aref A, 1998, Med Dosim, V23, P15, DOI 10.1016/S0958-3947(97)00116-7
[3]   Dosimetric analysis of intact breast irradiation in off-axis planes [J].
Buchholz, TA ;
Gurgoze, E ;
Bice, WS ;
Prestidge, BR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (01) :261-267
[4]   The use of compensators to optimise the three dimensional dose distribution in radiotherapy of the intact breast [J].
Carruthers, LJ ;
Redpath, AT ;
Kunkler, IH .
RADIOTHERAPY AND ONCOLOGY, 1999, 50 (03) :291-300
[5]   3-DIMENSIONAL PHOTON DOSE DISTRIBUTIONS WITH AND WITHOUT LUNG CORRECTIONS FOR TANGENTIAL BREAST INTACT TREATMENTS [J].
CHIN, LM ;
CHENG, CW ;
SIDDON, RL ;
RICE, RK ;
MIJNHEER, BJ ;
HARRIS, JR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1989, 17 (06) :1327-1335
[6]  
Chu J. C. H., 1985, INT J RADIAT ONCOL, V11, P163
[7]   TANGENTIAL BREAST IRRADIATION - SIMPLE IMPROVEMENTS [J].
CROSS, P ;
JOSEPH, DJ ;
CANT, J ;
COOPER, SG ;
DENHAM, JW .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 23 (02) :433-442
[8]   Patterns of dose variability in radiation prescription of breast cancer [J].
Das, IJ ;
Cheng, CW ;
Fein, DA ;
Fowble, B .
RADIOTHERAPY AND ONCOLOGY, 1997, 44 (01) :83-89
[9]   THE INFLUENCE OF LUNG DENSITY CORRECTIONS ON TREATMENT PLANNING FOR PRIMARY BREAST-CANCER [J].
FRAASS, BA ;
LICHTER, AS ;
MCSHAN, DL ;
YANKE, BR ;
DIAZ, RF ;
YEAKEL, KS ;
VANDEGEIJN, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 14 (01) :179-190
[10]  
GOITEIN M, 1982, PROGR MED RAD PHYSIC, V1, P195