Poly (methacrylic acid-ethylene glycol dimethacrylate) monolithic capillary for in-tube solid phase microextraction coupled to high performance liquid chromatography and its application to determination of basic drugs in human serum

被引:162
作者
Fan, Y [1 ]
Feng, YQ [1 ]
Da, SL [1 ]
Shi, ZG [1 ]
机构
[1] Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
关键词
poly (methacrylic acid-ethylene glycol dimethacrylate); monolithic capillary column; in-tube SPME; liquid chromatography; theobromine; theophylline; caffeine;
D O I
10.1016/j.aca.2004.07.052
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A poly (methacrylic acid-ethylene glycol dimethacrylate) monolithic capillary column was prepared for in-tube solid-phase microextraction. Comparing with the commonly used open tubular extraction capillary, which cannot provide sufficient extraction efficiency since the ratio of its coating volume to that of the capillary void volume is relatively small, the monolithic column with greater phase ratio combined with convective mass transfer provides the possibility to improve the extraction efficiency with shorter capillary. As to poly (methacrylic acid-ethylene glycol dimethacrylate), its hydrophobic main chains and acidic pendant groups make it a superior material for extraction of basic analytes from aqueous matrix. An on-line monolithic capillary column solid phase microextraction (SPME) method was developed for determination of theobromine, theophylline and caffeine in serum samples. The high extraction efficiency was obtained for all the three analytes, yielding the detection limits of 12, 8 and 6.5 ng/mL by UV detection, respectively. Excellent method reproducibility (R.S.D. < 2.9%) was found over a linear dynamic range of 0.05-2 mug/mL in serum sample. The monolithic capillary column was proved to be reusable in coping with serum samples, which would facilitate practical determination of basic drugs. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:251 / 258
页数:8
相关论文
共 28 条
  • [1] Simultaneous determination of caffeine, theobromine and theophylline in foods and pharmaceutical preparations by using ion chromatography
    Chen, Q
    Mou, S
    Hou, X
    Ni, Z
    [J]. ANALYTICA CHIMICA ACTA, 1998, 371 (2-3) : 287 - 296
  • [2] Automated in-tube solid-phase microextraction coupled to high-performance liquid chromatography
    Eisert, R
    Pawliszyn, J
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (16) : 3140 - 3147
  • [3] FAN Y, IN PRESS TALANTA
  • [4] Fritless packed columns for capillary electrochromatography: Separation of uncharged compounds on hydrophobic hydrogels
    Fujimoto, C
    Fujise, Y
    Matsuzawa, E
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (17) : 2753 - 2757
  • [5] CAPILLARY ELECTROCHROMATOGRAPHY OF SMALL MOLECULES IN POLYACRYLAMIDE GELS WITH ELECTROOSMOTIC FLOW
    FUJIMOTO, C
    KINO, J
    SAWADA, H
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1995, 716 (1-2) : 107 - 113
  • [6] Use of novel solid-phase extraction sorbent materials for high-performance liquid chromatography quantitation of caffeine metabolism products methylxanthines and methyluric acids in samples of biological origin
    Georga, KA
    Samanidou, VF
    Papadoyannis, IN
    [J]. JOURNAL OF CHROMATOGRAPHY B, 2001, 759 (02): : 209 - 218
  • [7] Jinno K, 2001, ELECTROPHORESIS, V22, P3785, DOI 10.1002/1522-2683(200109)22:17<3785::AID-ELPS3785>3.0.CO
  • [8] 2-U
  • [9] Extraction of methylxanthines from human body fluids by solid-phase microextraction
    Kumazawa, T
    Seno, H
    Lee, XP
    Ishii, A
    Watanabe-Suzuki, K
    Sato, K
    Suzuki, O
    [J]. ANALYTICA CHIMICA ACTA, 1999, 387 (01) : 53 - 60
  • [10] CONTINUOUS BEDS FOR STANDARD AND MICRO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    LIAO, JL
    ZHANG, R
    HJERTEN, S
    [J]. JOURNAL OF CHROMATOGRAPHY, 1991, 586 (01): : 21 - 26