Electrogenerated chemiluminescence.: 80.: C-reactive protein determination at high amplification with [Ru(bpy)3]2+-containing microspheres

被引:139
作者
Miao, WJ [1 ]
Bard, AJ [1 ]
机构
[1] Univ Texas, Dept Chem & Biochem, Austin, TX 78712 USA
关键词
D O I
10.1021/ac048782s
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Biotinylated anti-C-reactive protein (CRP) species were attached to the surface of streptavidin-coated magnetic beads (MB) and avidin-coated polystyrene microspheres/ beads (PSB) entrapping a large number of electrogenerated chemiluminescence (ECL) labels (similar to10(9) Ru(bpy)(3)[B(C6F5)(4)](2)/bead) to form anti-CRP<---->MB and Ru(II)subset ofPSB/ avidin<---->anti-CRP conjugates, respectively. Sandwich-type RU(II)subset ofPSB/avidin<---->anti-CRP <CRP> anti-CRP<---->MB aggregates were formed when Ru(II)subset ofPSB/avidin<---->anti-CRP was mixed with anti-CRP<---->MB conjugates in the presence of analyte CRP. The newly formed aggregates were magnetically separated from the reaction media and dissolved in MeCN containing tri-n-propylamine as an ECL coreactant. ECL was carried out with a potential scan from 0 to 2.8 V vs Ag/Ag+, and the ECL intensity was found to be proportional to the analyte CRP concentration over the range of 0.010-10 mug/mL. The CRP concentration of an unknown human plasma specimen was measured by the standard addition method based on this technique. Elimination of the nonspecific adsorption of the CRP system with several different blocking agents was also studied, and 2.0% bovine serum albumin was found to be best.
引用
收藏
页码:7109 / 7113
页数:5
相关论文
共 41 条
[1]  
Ablij Hans, 2002, Eur J Intern Med, V13, P412, DOI 10.1016/S0953-6205(02)00132-2
[2]  
[Anonymous], SCI MED
[3]  
Bard A.J., 2004, ELECTROGENERATED CHE
[4]   High sensitivity C-reactive protein: An emerging role in cardiovascular risk assessment [J].
Benzaquen, LR ;
Yu, H ;
Rifai, N .
CRITICAL REVIEWS IN CLINICAL LABORATORY SCIENCES, 2002, 39 (4-5) :459-497
[5]  
CAUL EO, 1992, IMMUNOFLUORESCENCE A
[6]   Nanocrystal biolabels with releasable fluorophores for immunoassays [J].
Chan, CPY ;
Bruemmel, Y ;
Seydack, M ;
Sin, KK ;
Wong, LW ;
Merisko-Liversidge, E ;
Trau, D ;
Renneberg, R .
ANALYTICAL CHEMISTRY, 2004, 76 (13) :3638-3645
[7]   A microchip-based multianalyte assay system for the assessment of cardiac risk [J].
Christodoulides, N ;
Tran, M ;
Floriano, PN ;
Rodriguez, M ;
Goodey, A ;
Ali, M ;
Neikirk, D ;
McDevitt, JT .
ANALYTICAL CHEMISTRY, 2002, 74 (13) :3030-3036
[8]   C-reactive protein and cardiovascular disease: a review of risk prediction and interventions [J].
de Ferranti, S ;
Rifai, N .
CLINICA CHIMICA ACTA, 2002, 317 (1-2) :1-15
[9]  
*DYN BIOT INC, DYN DYN MYON STREPT
[10]   Scanning electrochemical microscopy. 37. Light emission by electrogenerated chemiluminescence at SECM tips and their application to scanning optical microscopy [J].
Fan, FRF ;
Cliffel, D ;
Bard, AJ .
ANALYTICAL CHEMISTRY, 1998, 70 (14) :2941-2948