Heart rhythm during syncope and presyncope:: Results of implantable loop recorders

被引:58
作者
Nierop, PR [1 ]
van Mechelen, R [1 ]
van Elsäcker, A [1 ]
Luijten, RHM [1 ]
Elhendy, A [1 ]
机构
[1] St Franciscus Gasthuis, Dept Cardiol, NL-3045 PM Rotterdam, Netherlands
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2000年 / 23卷 / 10期
关键词
syncope; recurrent syncope; ECG loop recorder; diagnosis; arrhythmia;
D O I
10.1046/j.1460-9592.2000.01532.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Ambulatory ECG monitoring in patients with recurrent syncope is nondiagnostic in the majority of cases. Recently, an ECG implantable loop recorder (ILR) has been introduced. The ILR performs continuous ECG monitoring over a period of at least 14 months. From February 1997 to September 1999, 35 patients underwent implantation of an ILR. During a mean follow-up of 11 +/- 8 months, 24 (69%) patients had recurrent syncope or presyncope events. Four (11%) patients were not capable of activating the ILR to save the event. A symptom-rhythm correlation could be studied in 20 (83%) of 24 patients. Forty of 44 recurrences were captured by the ILR. There were 14 (40%) patients with at least one syncopal episode. An arrhythmic cause for syncope was found in eight of them (bradycardia in four and tachycardia in four). In the other six patients the heart rhythm was normal. In 17 (49%) patients with 1-year follow-up, the mean syncope event rate 12 months before ILR implantation was 4.7 +/- 2.4, whereas the mean syncope event rate 12 months after ILR implantation was 1.3 +/- 0.7 (P < 0.01). Resolution of symptoms wets observed in 6 (17%) patients. These patients were significantly younger than patients without resolution (50 +/- 18 vs 69 +/- 24 years, p < 0.01) and five were women. Three (9%) patients died during follow-up, all of them were noncompliant during their follow-up. In conclusion, the ILR made symptom-rhythm correlation possible in 83% of patients with recurrent syncope. Syncope recurrences decreased significantly after implantation of the device, especially in the younger patients. Noncompliant patients had a high mortality rate.
引用
收藏
页码:1532 / 1538
页数:7
相关论文
共 24 条
[1]   ROLE OF CARDIAC ELECTROPHYSIOLOGIC STUDIES IN PATIENTS WITH UNEXPLAINED RECURRENT SYNCOPE [J].
AKHTAR, M ;
SHENASA, M ;
DENKER, S ;
GILBERT, CJ ;
RIZWI, N .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1983, 6 (02) :192-201
[2]   USEFULNESS OF CLINICAL CHARACTERISTICS IN PREDICTING THE OUTCOME OF ELECTROPHYSIOLOGIC STUDIES IN UNEXPLAINED SYNCOPE [J].
BACHINSKY, WB ;
LINZER, M ;
WELD, L ;
ESTES, NAM .
AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (12) :1044-1049
[3]   THE DURATION OF HOLTER MONITORING IN PATIENTS WITH SYNCOPE - IS 24 HOURS ENOUGH [J].
BASS, EB ;
CURTISS, EI ;
ARENA, VC ;
HANUSA, BH ;
CECCHETTI, A ;
KARPF, M ;
KAPOOR, WN .
ARCHIVES OF INTERNAL MEDICINE, 1990, 150 (05) :1073-1078
[4]   LONG-TERM PROGNOSIS OF PATIENTS UNDERGOING ELECTROPHYSIOLOGIC STUDIES FOR SYNCOPE OF UNKNOWN ORIGIN [J].
BASS, EB ;
ELSON, JJ ;
FOGOROS, RN ;
PETERSON, J ;
ARENA, VC ;
KAPOOR, WN .
AMERICAN JOURNAL OF CARDIOLOGY, 1988, 62 (17) :1186-1191
[5]   ARRHYTHMIAS DETECTED BY AMBULATORY MONITORING - LACK OF CORRELATION WITH SYMPTOMS OF DIZZINESS AND SYNCOPE [J].
CLARK, PI ;
GLASSER, SP ;
SPOTO, E .
CHEST, 1980, 77 (06) :722-725
[6]  
DIMARCO JP, 1990, ANN J MED, P11353
[7]   DIAGNOSTIC-VALUE OF PROGRAMMED VENTRICULAR STIMULATION IN PATIENTS WITH BIFASCICULAR BLOCK - A PROSPECTIVE-STUDY OF PATIENTS WITH AND WITHOUT SYNCOPE [J].
ENGLUND, A ;
BERGFELDT, L ;
REHNQVIST, N ;
ASTROM, H ;
ROSENQVIST, M .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 26 (06) :1508-1515
[8]   Utility and cost of event recorders in the diagnosis of palpitations, presyncope, and syncope [J].
Fogel, RI ;
Evans, JJ ;
Prystowsky, EN .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (02) :207-&
[9]   Gender differences in presentation, management, and cardiac event-free survival in patients with syncope [J].
Freed, LA ;
Eagle, KA ;
Mahjoub, ZA ;
Gold, MR ;
Smith, AJC ;
Terrell, LB ;
OGara, PT ;
Paul, SD .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 (09) :1183-1187
[10]   DIAGNOSTIC EFFICACY OF 24-HOUR ELECTROCARDIOGRAPHIC MONITORING FOR SYNCOPE [J].
GIBSON, TC ;
HEITZMAN, MR .
AMERICAN JOURNAL OF CARDIOLOGY, 1984, 53 (08) :1013-1017