Improvement of confocal Spectral Precision Distance Microscopy (SPDM)

被引:8
作者
Edelmann, P [1 ]
Cremer, C [1 ]
机构
[1] Heidelberg Univ, Kirchhoff Inst Phys, D-69120 Heidelberg, Germany
来源
OPTICAL DIAGNOSTICS OF LIVING CELLS III | 2000年 / 3921卷
关键词
Spectral Precision Distance Microscopy (SPDM); confocal Laser-Scanning microscopy (CLSM); chromatic shift; aberration; distance microscopy; localization accuracy;
D O I
10.1117/12.384226
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
In recent years, confocal Laser-Scanning microscopy (CLSM) became the most sophisticated microscopic technique for 3D-imaging in biomedical microstructure research. Experimental evidence, however, showed that under optical conditions relevant e.g. for nuclear genome analysis, the resolution of such an instrument as given by the Full Width at Half Maximum (FWHM) of the confocal point-spread function (PSF) is limited to about greater than or equal to 0.3 mu m laterally and to about greater than or equal to 0.7 mu m axially. A recently introduced light-microscopic approach, termed Spectral Precision Distance Microscopy (SPDM), allows the precise measurement of distances and angles between specifically labeled target sites far below the above mentioned resolution limit. SPDM is based on the use of "point-like" objects labeled with different spectral signatures. Since in most cases, spectral signature differences have been realized by variation of excitation/ fluorescence emission spectra, the calibration of chromatic aberrations is of utmost importance. Here, an improved procedure for the correction of chromatic shifts is presented. Statistical errors introduced by the localization accuracy can be minimized by the multiple measurement of the 3D-distances between the same specifically labeled target sites in a number of cases and subsequent averaging. However, the thus obtained mean distance, the estimate for the "true" distance may be biased and therefore limited by the localization accuracy. Virtual microscopy simulations of test objects using an experimentally obtained PSF, showed that a few thousand detected fluorescence photons are sufficient to measure reliably distances down to about 20 nm (about 1/30 of the wavelength used), if other sources of error apart from voxelization, digitization and photon noise are negligible.
引用
收藏
页码:313 / 320
页数:8
相关论文
共 20 条
[1]   High-precision distance measurements and volume-conserving segmentation of objects near and below the resolution limit in three-dimensional confocal fluorescence microscopy [J].
Bornfleth, H ;
Sätzler, K ;
Eils, R ;
Cremer, C .
JOURNAL OF MICROSCOPY-OXFORD, 1998, 189 :118-136
[2]  
Bornfleth H, 1999, HDB COMPUTER VISION, VIII, P859
[3]   Semiconductor nanocrystals as fluorescent biological labels [J].
Bruchez, M ;
Moronne, M ;
Gin, P ;
Weiss, S ;
Alivisatos, AP .
SCIENCE, 1998, 281 (5385) :2013-2016
[4]   STRATEGIES FOR ATTAINING SUPERRESOLUTION USING SPECTROSCOPIC DATA AS CONSTRAINTS [J].
BURNS, DH ;
CALLIS, JB ;
CHRISTIAN, GD ;
DAVIDSON, ER .
APPLIED OPTICS, 1985, 24 (02) :154-161
[5]  
CREMER C, 1996, Patent No. 19654
[6]   ROLE OF CHROMOSOME TERRITORIES IN THE FUNCTIONAL COMPARTMENTALIZATION OF THE CELL-NUCLEUS [J].
CREMER, T ;
KURZ, A ;
ZIRBEL, R ;
DIETZEL, S ;
RINKE, B ;
SCHROCK, E ;
SPEICHER, MR ;
MATHIEU, U ;
JAUCH, A ;
EMMERICH, P ;
SCHERTHAN, H ;
RIED, T ;
CREMER, C ;
LICHTER, P .
COLD SPRING HARBOR SYMPOSIA ON QUANTITATIVE BIOLOGY, 1993, 58 :777-792
[7]  
Edelmann P, 1999, OPTIK, V110, P194
[8]  
EDELMANN P, 1998, P SOC PHOTO-OPT INS, V3568, P89
[9]   Fast-FISH detection and semi-automated image analysis of numerical chromosome aberrations in hematological malignancies [J].
Esa, A ;
Trakhtenbrot, L ;
Hausmann, M ;
Rauch, J ;
Brok-Simoni, F ;
Rechavi, G ;
Ben-Bassat, I ;
Cremer, C .
ANALYTICAL CELLULAR PATHOLOGY, 1998, 16 (04) :211-222
[10]  
ESA A, 1999, UNPUB J MICROS