Mechanical support for isolated right ventricular failure in patients after cardiotomy

被引:68
作者
Moazami, N [1 ]
Pasque, MK [1 ]
Moon, MR [1 ]
Herren, RL [1 ]
Bailey, MS [1 ]
Lawton, JS [1 ]
Damiano, RJ [1 ]
机构
[1] Washington Univ, Sch Med, Div Cardiothorac Surg, St Louis, MO 63110 USA
关键词
D O I
10.1016/j.healun.2003.09.022
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Patients with acute right ventricular (RV) failure after cardiotomy have a poor prognosis. We evaluated the surgical and long-term outcomes of patients with isolated RV failure that required right ventricular assist device (RVAD) support. Methods: Between 1991 and 2002, a total of 30 patients received RVAD support for isolated RV dysfunction. We evaluated survival, duration of mechanical support, post-RVAD hemodynamics, and RV function. Results: Right ventricular failure developed in patients after coronary artery bypass surgery alone or combined with valve surgery (12 patients), valvular surgery (5), ascending aortic replacement (6), heart transplantation (3), and pulmonary endarterectomy (4). Mean age was 58 15 years, and 17 (57%) were women. Surgery was emergent in 5 (73%) patients. Centrifugal pumps were used in 21, extra corporeal membrane oxygenation in 8, and as Abiomed pump in 1 patient. Overall, 17 (57%) patients died while receiving assist device support, 3 of sepsis, 2 of stroke, and 12 of inability to wean from the device. We successfully weaned RVAD support in 13 (43%) patients, with a median duration of support of 5 days (range, 2 - 8 days). Ten survived to hospital discharge. After RVAD removal, mean pulmonary artery pressure was 25.1 +/- 6.5 mm Hg, cardiac output was 4.8 +/- 2.0 liters, and central venous pressure was 16.5 +/- 3.7 mm Hg. Echocardiogram after RVAD removal showed normal RV function in 2 patients and in 11 patients demonstrated improvement. Conclusion: After cardiotomy, patients with RV failure who require mechanical support continue to have increased mortality. For patients successfully weaned from the RVAD, residual RV dysfunction is compatible with survival. More liberal use of RV mechanical support may be indicated for patients with acute RV failure. Copyright (C) 2004 by the International Society for Heart and Lung Transplantation.
引用
收藏
页码:1371 / 1375
页数:5
相关论文
共 17 条
[1]   Experience with right ventricular assist devices for perioperative right sided circulatory failure [J].
Chen, JM ;
Levin, HR ;
Rose, EA ;
Addonizio, LJ ;
Landry, DW ;
Sistino, JJ ;
Michler, RE ;
Oz, MC .
ANNALS OF THORACIC SURGERY, 1996, 61 (01) :305-310
[2]   HEMODYNAMICALLY IMPORTANT RIGHT VENTRICULAR INFARCTION - FOLLOW-UP EVALUATION OF RIGHT VENTRICULAR SYSTOLIC FUNCTION AT REST AND DURING EXERCISE WITH RADIONUCLIDE VENTRICULOGRAPHY AND RESPIRATORY GAS-EXCHANGE [J].
DELLITALIA, LJ ;
LEMBO, NJ ;
STARLING, MR ;
CRAWFORD, MH ;
SIMMONS, RS ;
LASHER, JC ;
BLUMHARDT, R ;
LANCASTER, J ;
OROURKE, RA .
CIRCULATION, 1987, 75 (05) :996-1003
[3]   Improved results for postcardiotomy cardiogenic shock with the use of implantable left ventricular assist devices [J].
DeRose, JJ ;
Umana, JP ;
Argenziano, M ;
Catanese, KA ;
Levin, HR ;
Sun, BC ;
Rose, EA ;
Oz, MC .
ANNALS OF THORACIC SURGERY, 1997, 64 (06) :1757-1762
[4]   Preoperative risk factors for right ventricular failure after implantable left ventricular assist device insertion [J].
Fukamachi, K ;
McCarthy, PM ;
Smedira, NG ;
Vargo, RL ;
Starling, RC ;
Young, JB .
ANNALS OF THORACIC SURGERY, 1999, 68 (06) :2181-2184
[5]   Short-term outcome and predictors of adverse events following pulmonary thromboendarterectomy [J].
Gilbert, TB ;
Gaine, SP ;
Rubin, LJ ;
Sequeira, AJ .
WORLD JOURNAL OF SURGERY, 1998, 22 (10) :1029-1032
[6]   Pathophysiology and clinical management of right heart ischemia [J].
Goldstein, JA .
CURRENT OPINION IN CARDIOLOGY, 1999, 14 (04) :329-339
[7]   Pulmonary thromboendarterectomy [J].
Jamieson, SW .
HEART, 1998, 79 (02) :118-120
[8]   THE EARLY RECOGNITION OF RIGHT VENTRICULAR INFARCTION - DIAGNOSTIC-ACCURACY OF THE ELECTROCARDIOGRAPHIC V4R LEAD [J].
KLEIN, HO ;
TORDJMAN, T ;
NINIO, R ;
SARELI, P ;
OREN, V ;
LANG, R ;
GEFEN, J ;
PAUZNER, C ;
DISEGNI, E ;
DAVID, D ;
KAPLINSKY, E .
CIRCULATION, 1983, 67 (03) :558-565
[9]   SENSITIVITY AND SPECIFICITY OF HEMODYNAMIC CRITERIA IN THE DIAGNOSIS OF ACUTE RIGHT VENTRICULAR INFARCTION [J].
LOPEZSENDON, J ;
COMACANELLA, I ;
GAMALLO, C .
CIRCULATION, 1981, 64 (03) :515-525
[10]   Predictors of severe right ventricular failure after Implantable left ventricular assist device insertion: Analysis of 245 patients [J].
Ochiai, Y ;
McCarthy, PM ;
Smedira, NG ;
Banbury, MK ;
Navia, JL ;
Feng, JY ;
Hsu, AP ;
Yeager, ML ;
Buda, T ;
Hoercher, KJ ;
Howard, MW ;
Takagaki, M ;
Doi, K ;
Fukamachi, K .
CIRCULATION, 2002, 106 (13) :I198-I202