Correlations between local conversion and hydrodynamics in a 3-D fixed-bed esterification process: An MRI and lattice-Boltzmann study

被引:37
作者
Yuen, EHL
Sederman, AJ
Sani, F
Alexander, P
Gladden, LF
机构
[1] Univ Cambridge, Dept Chem Engn, Cambridge CB2 3RA, England
[2] Univ Cambridge, Cavendish Lab, Dept Phys, Cambridge CB3 0HE, England
基金
英国工程与自然科学研究理事会;
关键词
catalysis; magnetic resonance imaging; reaction engineering; visualisation; packed bed; esterification;
D O I
10.1016/S0009-2509(02)00586-9
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In situ magnetic resonance (MR) visualisation techniques are used to study chemical con-version within a fixed-bed reactor. The reaction chosen for study is the esterification of acetic acid by methanol, catalysed by an acidic ion exchange catalyst. MR visualisation shows that fractional variations in steady-state conversion within slice sections of the bed, perpendicular to the direction of superficial flow, are of order 20%. The origin of this heterogeneity in conversion lies in the heterogeneity in the fluid flow field within the bed as is seen directly from MR flow visualisation. A lattice-Boltzmann code is validated for the prediction of the flow field within this fixed bed of porous resin packing. The lattice-Boltzmann predictions of the flow field are then used to explore any dependence of local conversion within the bed with locally averaged fluid velocity, over varying length-scales within the bed. These data report a first demonstration that MR visualisation techniques can be used to gain,insight into the true rate-limiting processes influencing the performance of fixed-bed reactors. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:613 / 619
页数:7
相关论文
共 13 条
[1]  
AGREDA VH, 1990, CHEM ENG PROG, V86, P40
[2]   On boundary conditions in lattice Boltzmann methods [J].
Chen, SY ;
Martinez, D ;
Mei, RW .
PHYSICS OF FLUIDS, 1996, 8 (09) :2527-2536
[3]  
Harris R.K., 1983, NUCL MAGNETIC RESONA
[4]   Lattice Boltzmann model for the incompressible Navier-Stokes equation [J].
He, XY ;
Luo, LS .
JOURNAL OF STATISTICAL PHYSICS, 1997, 88 (3-4) :927-944
[5]   RARE IMAGING - A FAST IMAGING METHOD FOR CLINICAL MR [J].
HENNIG, J ;
NAUERTH, A ;
FRIEDBURG, H .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (06) :823-833
[6]   VOLUME-SELECTIVE MULTIPULSE SPIN-ECHO SPECTROSCOPY [J].
KIMMICH, R ;
HOEPFEL, D .
JOURNAL OF MAGNETIC RESONANCE, 1987, 72 (02) :379-384
[7]   Correlations between dispersion and structure in porous media probed by nuclear magnetic resonance [J].
Manz, B ;
Alexander, P ;
Gladden, LF .
PHYSICS OF FLUIDS, 1999, 11 (02) :259-267
[8]   SPATIALLY RESOLVED HIGH-RESOLUTION SPECTROSCOPY BY 4-DIMENSIONAL NMR [J].
MAUDSLEY, AA ;
HILAL, SK ;
PERMAN, WH ;
SIMON, HE .
JOURNAL OF MAGNETIC RESONANCE, 1983, 51 (01) :147-152
[9]  
Sani F.M., 2002, THESIS U CAMBRIDGE
[10]   Structure-flow correlations in packed beds [J].
Sederman, AJ ;
Johns, ML ;
Alexander, P ;
Gladden, LF .
CHEMICAL ENGINEERING SCIENCE, 1998, 53 (12) :2117-2128