A dual electrospray ionization source combined with hexapole accumulation to achieve high mass accuracy of biopolymers in fourier transform ion cyclotron resonance mass spectrometry

被引:101
作者
Hannis, JC [1 ]
Muddiman, DC [1 ]
机构
[1] Virginia Commonwealth Univ, Dept Chem, Richmond, VA 23284 USA
关键词
D O I
10.1016/S1044-0305(00)00160-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A dual electrospray ionization (ESI) source employed with hexapole accumulation and gated trapping provides a novel method of using an internal standard to achieve high mass accuracies in Fourier transform ion cyclotron resonance mass spectrometry. Two ESI emitters are sequentially positioned in front of the heated metal capillary inlet by a solenoid fitted to an XYZ micromanipulator; one emitter contains the analyte(s) of interest and the other an internal standard. A 5 V transistor-transistor logic pulse from the data station controls the solenoid by means of a solid-state relay so that matching of spectral peak intensities (i.e., analyte and internal standard intensities) can be accomplished by adjusting the hexapole accumulation time for each species. Polythymidine, d(pT)(18), was used as the internal standard for all studies reported here. The absolute average error for an internally calibrated 15-mer oligonucleotide (theoretical monoisotopic mass = 4548.769 Da) was -1.1 ppm (external calibration: 41 ppm) with a standard deviation of +/-3.0 ppm (external calibration: +/-24 ppm) for a total of 25 spectra obtained at various hexapole accumulation time ratios. Linear least squares regression analysis was carried out and revealed a linear dependence of the magnitudes of the peak height ratios (analyte/internal standard) vs. hexapole accumulation time ratios (analyte/internal standard) which is described by the following equation: y = 0.45 x -0.02. The fitted line had a %RSD of the slope of 28% with an R-2 of 0.93. The applicability of this methodology was extended to a polymerase chain reaction product with a theoretical average molecular mass of 50,849.20 Da. With the internal standard, d(pT)(18), an absolute average error of -8.9 ppm (external calibration: 44 ppm) based on five measurements was achieved with a standard deviation of 11 ppm (external calibration: +/-36 ppm), thus illustrating this method's use for characterizing large biomolecules such as those encountered in genomics and proteomics related research. (J Am Soc Mass Spectrom 2000, 11, 876-883) (C) 2000 American Society for Mass Spectrometry.
引用
收藏
页码:876 / 883
页数:8
相关论文
共 55 条
[1]   Accurate base composition of double-strand DNA by mass spectrometry [J].
Aaserud, DJ ;
Kelleher, NL ;
Little, DP ;
McLafferty, FW .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1996, 7 (12) :1266-1269
[2]  
Andrien B. A., 1998, P 46 ASMS C MASS SPE, P889
[3]   Exact mass measurements using a 7 Tesla Fourier transform ion cyclotron resonance mass spectrometer in a good laboratory practices-regulated environment [J].
Burton, RD ;
Matuszak, KP ;
Watson, CH ;
Eyler, JR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (12) :1291-1297
[4]  
Cao P, 1998, RAPID COMMUN MASS SP, V12, P864, DOI 10.1002/(SICI)1097-0231(19980715)12:13<864::AID-RCM244>3.0.CO
[5]  
2-G
[6]   MODELING COULOMB EFFECTS IN FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY BY CHARGED DISKS AND CHARGED CYLINDERS [J].
CHEN, SP ;
COMISAROW, MB .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1992, 6 (01) :1-3
[7]   AN ELECTROSPRAY-IONIZATION MASS-SPECTROMETER WITH NEW FEATURES [J].
CHOWDHURY, SK ;
KATTA, V ;
CHAIT, BT .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1990, 4 (03) :81-87
[9]   ELECTROSPRAY IONIZATION MAGNETIC-SECTOR MASS-SPECTROMETRY - CALIBRATION, RESOLUTION, AND ACCURATE MASS MEASUREMENTS [J].
CODY, RB ;
TAMURA, J ;
MUSSELMAN, BD .
ANALYTICAL CHEMISTRY, 1992, 64 (14) :1561-1570
[10]   ERROR ESTIMATES FOR FINITE ZERO-FILLING IN FOURIER-TRANSFORM SPECTROMETRY [J].
COMISAROW, MB ;
MELKA, JD .
ANALYTICAL CHEMISTRY, 1979, 51 (13) :2198-2203