Use of the GlucoWatch biographer in children with type 1 diabetes

被引:56
作者
Chase, HP
Roberts, MD
Wightman, C
Klingensmith, G
Garg, SK
Van Wyhe, M
Desai, S
Harper, W
Lopatin, M
Bartkowiak, M
Tamada, J
Eastman, RC
机构
[1] Cygnus Inc, Redwood City, CA 94063 USA
[2] Univ Colorado, Hlth Sci Ctr, Dept Pediat, Barbara Davis Ctr Childhood Diabet, Denver, CO 80262 USA
关键词
type; 1; diabetes; GlucoWatch biographer; hypoglycemia; hemoglobin A1c;
D O I
10.1542/peds.111.4.790
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Objective. To determine whether use of the GlucoWatch biographer improves glucose control in children and adolescents with type 1 diabetes. Methods. Forty children in poor glucose control (glycohemoglobin [HbA1c] > 8%) were randomized to diabetes management with or without glucose monitoring using the biographer. Conventional glucose monitoring was performed 4 times daily in both groups. Those randomized to the biographer group were asked to wear the device 4 times per week for 3 months (intervention phase) and to perform blood glucose monitoring if the biographer alerted them that glucose was less than or equal to70 mg/dL (3.9 mmol/L) or greater than or equal to300 mg/dL (16.7 mmol/L). After 3 months, all patients received biographers and were followed for 6 months (observation phase). HbA1c values were determined at baseline and after 1, 3, 6, and 9 months. Results. The median HbA1c was 8.6% and 8.9% (control versus biographer) at baseline and was significantly lower in the biographer group after 3 months (8.4% vs 9%). More hypoglycemia was detected when subjects were wearing the biographer, especially at night. No severe hypoglycemia occurred. During the observation phase, HbA1c values at 6 months were 8.5% and 8.3% and at 9 months were 8.6% and 8.4% in the control and biographer groups, respectively. Two children dropped out of the study, 1 because of skin irritation from using the device. Conclusions. The GlucoWatch biographer was well tolerated by children and adolescents and significantly improved glucose control compared with standard therapy. The use of the biographer with an alarm to detect nocturnal hypoglycemia has the potential to increase the safety of diabetes management in children.
引用
收藏
页码:790 / 794
页数:5
相关论文
共 19 条
  • [1] AMIN R, 2002, DIABETES S2, V51, pA2
  • [2] [Anonymous], 1969, COURSE NONPARAMETRIC
  • [3] SEVERE HYPOGLYCEMIA IN IDDM CHILDREN
    BERGADA, I
    SUISSA, S
    DUFRESNE, J
    SCHIFFRIN, A
    [J]. DIABETES CARE, 1989, 12 (04) : 239 - 244
  • [4] Boland EA, 2002, DIABETES, V51, pA119
  • [5] The impact of the Diabetes Control and Complications Trial and Humalog insulin or glycohemoglobin levels and severe hypoglycemia in type 1 diabetes
    Chase, HP
    Lockspeiser, T
    Peery, B
    Shepherd, M
    MacKenzie, T
    Anderson, J
    Garg, SK
    [J]. DIABETES CARE, 2001, 24 (03) : 430 - 434
  • [6] Continuous subcutaneous glucose monitoring in children with type 1 diabetes
    Chase, HP
    Kim, LM
    Owen, SL
    MacKenzie, TA
    Klingensmith, GJ
    Murtfeldt, R
    Garg, SK
    [J]. PEDIATRICS, 2001, 107 (02) : 222 - 226
  • [7] FEAR OF HYPOGLYCEMIA - QUANTIFICATION, VALIDATION, AND UTILIZATION
    COX, DJ
    IRVINE, A
    GONDERFREDERICK, L
    NOWACEK, G
    BUTTERFIELD, J
    [J]. DIABETES CARE, 1987, 10 (05) : 617 - 621
  • [8] DCCT Res Grp, 1991, AM J MED, V90, P450, DOI 10.1016/0002-9343(91)80085-Z
  • [9] DCCT Res Grp, 1988, DIABETES CARE, V11, P725
  • [10] DRAIZE JH, 1965, DERMAL TOXICITY, P45