Simultaneous speciation of redox species of arsenic and selenium using an anion-exchange microbore column coupled with a micro-concentric nebulizer and an inductively coupled plasma mass spectrometer as detector

被引:54
作者
Woller, A
Garraud, H
Boisson, J
Dorthe, AM
Fodor, P
Donard, OFX
机构
[1] Univ Hort & Food Ind, Dept Chem & Biochem, H-1114 Budapest, Hungary
[2] CEA Cadarache, LGEM, SESD, DESD,DCC, F-13108 St Paul Durance, France
[3] Univ Pau & Pays Adour, CNRS, EP 132, Lab Chim Bioinorgan & Environm, F-64000 Pau, France
[4] INRA, Unite Agron, F-33883 Villenave Dornon, France
[5] Ecole Natl Super Chim & Phys Bordeaux, F-33402 Talence, France
关键词
redox species; arsenic and selenium speciation; anion-exchange microbore column; micro-concentric nebulizer; inductively coupled plasma mass spectrometry; factorial experimental design;
D O I
10.1039/a704772j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Speciation methods for trace metals in the environment need rapid and accurate analyses, The simultaneous determination of redox species of arsenic (As-III and As-V) and selenium (Se-IV and Se-VI) has been carried out by coupling a microbore column with a micro-concentric nebulizer (MCN) and inductively coupled plasma mass spectrometry (ICP-MS), The MCN, with its ability to nebulize liquids at low flow rates, was adapted to a small bore (2 mm id) microbore anion-exchange column, After optimizing the parameters of the MCN by factorial experimental-design, an evaluation of the separation of redox As and Se species was carried out, The method was applied to the determination of the four species in a sample recommended for Se speciation studies, in a spilled natural water and in polluted soil leachings., No interference of (ArCl)-Ar-40-Cl-35 on As-75 was observed when natural water samples were analyzed. The method showed good accuracy and repeatability in addition to facile handling and development. A detection limit of 1 ng ml(-1) was found for the arsenic species and 4 ng ml(-1) for the selenium species.
引用
收藏
页码:141 / 149
页数:9
相关论文
共 33 条
[1]  
AMRAN B, 1995, QUALITY ASSURANCE EN, P285
[2]  
[Anonymous], 1988, METHODE PLANS EXPERI
[3]   Determination of rare earth elements in wine by inductively coupled plasma mass spectrometry using a microconcentric nebulizer [J].
Augagneur, S ;
Medina, B ;
Szpunar, J ;
Lobinski, R .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (09) :713-721
[4]   Speciation of inorganic selenium using flow injection hydride generation atomic fluorescence spectrometry [J].
Bryce, DW ;
Izquierdo, A ;
DeCastro, MDL .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (12) :1059-1063
[5]  
CAI Y, 1995, ANAL CHIM ACTA, V314, P825
[6]  
CAMARA C, 1995, QUALITY ASSURANCE EN, P235
[7]   Chemical speciation by flow-injection analysis. A review [J].
Campanella, L ;
Pyrzynska, K ;
Trojanowicz, M .
TALANTA, 1996, 43 (06) :825-838
[8]  
*CET TECHN, MCN 100 MICR CONC NE
[9]   HITACHI ZEEMAN GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETER AS A SELENIUM-SPECIFIC DETECTOR FOR ION CHROMATOGRAPHY - SEPARATION AND DETERMINATION OF SELENITE AND SELENATE [J].
CHAKRABORTI, D ;
HILLMAN, DCJ ;
IRGOLIC, KJ ;
ZINGARO, RA .
JOURNAL OF CHROMATOGRAPHY, 1982, 249 (01) :81-92
[10]  
CRAIG PJ, 1986, OCCURRENCE PATHWAYS