Time-resolved contrast-enhanced pulmonary MR angiography using sensitivity encoding (SENSE)

被引:47
作者
Ohno, Y
Kawamitsu, H
Higashino, T
Takenaka, D
Watanabe, H
van Cauteren, M
Fujii, M
Hatabu, H
Sugimura, K
机构
[1] Kobe Univ, Dept Radiol, Grad Sch Med, Dept Radiol,Chuo Ku, Kobe, Hyogo 6500017, Japan
[2] Kobe Ekisdaikai Hosp, Dept Radiol, Kobe, Hyogo, Japan
[3] Philips Med Syst Corp, Tokyo, Japan
[4] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
关键词
lung; magnetic resonance (MR); angiography; sensitivity encoding; fast imaging;
D O I
10.1002/jmri.10261
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the relationship between gadolinium concentration and signal-to-noise ratio (SNR) on sensitivity encoding (SENSE) images, and determine the appropriate bolus injection protocol for visualizing pulmonary circulation. Materials and Methods: Eighteen different gadolinium concentration phantoms (0,0.01,0.05,0.1,0.2,0.4,0.6,0.8, 1.0, 1.2, 1.5, 2.0, 5.0, 10.0, 20.0, 30.0, 50.0, and 100.0 mmol/L) were analyzed to determine the relationship between gadolinium concentration and SNR on SENSE images in a phantom study. In an in vivo study, 3 mL (protocol A) or 6 mL (protocol B) of Gd-DTPA BMA at 3 mL/second, and 5 mL of Gd-DTPA BMA at 5 mL/second (protocol C) were administered to eight normal volunteers for contrast-enhanced (CE) pulmonary MR angiography (MRA) with SENSE. The peak SNRs of pulmonary parenchyma and the difference in SNR between pulmonary artery (PA) and pulmonary vein (PV) at peak SNR in the PA were statistically evaluated. Results: For each flip angle at each gadolinium concentration, the SNRs and contrast-to-noise ratios (CNRs) of the. SENSE images were significantly lower than those acquired with a nonparallel imaging technique (P < 0.05). The peak SNR of the pulmonary parenchyma, and differences in SNR between the PA and PV at the peak SNR of the PA obtained with a 5-mL/second bolus injection protocol were found to be significantly higher than those obtained with other protocols (P,< 0.05). Conclusion: 3D-CE-MRA,using SENSE demonstrated linearity between gadolinium concentration and SNR, and resulted in MRA with high spatial and temporal resolution with the, aid of a sharp bolus injection protocol.
引用
收藏
页码:330 / 336
页数:7
相关论文
共 42 条
  • [1] [Anonymous], 1988, MAGN RESON IMAGING, V6, P195
  • [2] Improved diffusion-weighted single-shot echo-planar imaging (EPI) in stroke using Sensitivity Encoding (SENSE)
    Bammer, R
    Keeling, SL
    Augustin, M
    Pruessmann, KP
    Wolf, R
    Stollberger, R
    Hartung, HP
    Fazekas, F
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) : 548 - 554
  • [3] Accuracy of MR angiography compared with radionuclide scanning in identifying the cause of pulmonary arterial hypertension
    Bergin, CJ
    Hauschildt, J
    Rios, G
    Belezzuoli, EV
    Huynh, T
    Channick, RN
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (06) : 1549 - 1555
  • [4] Bernstein MA, 2001, MAGNET RESON MED, V46, P955, DOI 10.1002/mrm.1282
  • [5] Sensitivity-encoded spectroscopic imaging
    Dydak, U
    Weiger, M
    Pruessmann, KP
    Meier, D
    Boesiger, P
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (04) : 713 - 722
  • [6] *EEC CONC RES PROJ, 1988, MAGN RESON IMAGING, V6, P179
  • [7] Frayne R, 2000, J MAGN RESON IMAGING, V12, P476, DOI 10.1002/1522-2586(200009)12:3<476::AID-JMRI14>3.0.CO
  • [8] 2-F
  • [9] Golay X, 2000, MAGNET RESON MED, V43, P779, DOI 10.1002/1522-2594(200006)43:6<779::AID-MRM1>3.0.CO
  • [10] 2-4